10.1 “START/STOp” - pRIMING BUTTON
This allows to
start
or
stop
pump programmed operations as well as to
prime
the pump. Pressing this button, while the
pump is working, will display
OFF
(flashing). Continuing to press the button
“START-STOp”
while
OFF
is showing, will
change the display into
MAN
, and the pump will deliver 80 strokes. During all this time, the external input signal is
off
.
Releasing the button pump will return the pump to the original programmed operations.
10.2 INFORMATION ON DISpLAY
[
LO VI
]
When power supply voltage drops below the permissible minimum,
minimum allowed being
92Vac (for 115Vac version)
or 184Vac (for 230Vac version), pump will stop and display will show [LO VI], meaning LOW VOLTAGE INPUT.
[
hI VI
]
When power supply voltage increases above permissible maximum,
maximum allowed being
134Vac (for 115Vac
version) or 268Vac (for 230Vac version), pump will stop and display will show [HI VI], meaning HIGH VOLTAGE INPUT.
[
SYNC
]
Every time pump is powered by the main electrical supply, display shows [
SYNC
] for 1 second. The message indicates that
the microprocessor is analysing power supply frequency. This auto-analysis operation, along with power supply verification,
ensure the best and most accurate results in dosing operation, frequency or voltage fluctuations.
[TANk LEVEL]
Level probe signals when additive level in the tank is below allowable height. The pump therefore stops. Display will show
[TANk LEVEL]
. Once additive level is restored, message is turned-off and pump will restart.
[DATA ERROR]
It appears every time there has been a mistake in programming. Re-enter the
programming mode
and follow instructions.
[MEM ERROR]
Indicates a problem with microprocessor memory.
For assistance, please contact EMEC service department or any
other authorized personnel.
[MAN]
Operator is priming the pump.
[OFF]
Pump is OFF.
[RANGE]
Input signal is not received or
beyond programming threshold values
.