Installation
Preparing the combustion chamber
37
9.2
Preparing the combustion
chamber
Position the combustion chamber
The combustion chamber can be moved either with a
crane or a lifting device (forklift truck or pallet jack).
Fig. 9-3: Combustion chamber
When lifting with a crane, a 4-strand chain sling
must be used. The chain angle may not exceed
45°.
When lifting with a forklift truck, the length of the fork
must be at least 1700 mm.
Fitting the stoker to the combustion chamber
Slide the stoker unit onto the combustion chamber and
initially only install hand-tight with the M10 x 20
screws. Then adjust the height of the stoker with the
levelling feet and evenly tighten the M10 x 20 screws.
During assembly, make sure not to damage the
ceramic seal affixed to the stoker flange.
Fig. 9-4: Seal on stoker flange