CAUTION–  WHEN INSTALLING THE PRODUCT

 

  •   Plugging in or unplugging the power cord with wet hands may result in electric shock.
  •   Never move the device with the power cord plugged into the wall, as damage to the power cord may result. 
  •   When unplugging the cord from the wall, grasp the plug, NOT the cord.
  •   Never install this device in humid or dusty locations, nor in direct sunlight, near sources of heat, or in areas where sooty smoke or 

steam are present. Fire and electric shock may result.

  •   Keep all sides of the device at least 3

1

2

” away from objects that may obstruct air flow to prevent the unit’s internal temperature 

rise.

WARNING – WHEN THE DEVICE IS IN USE

 

  •   To prevent electric shock, do not remove the device cover as there are high voltage components inside. Refer all servicing to ETA 

Systems.

  •   Should any of the following irregularities occur during use, immediately switch off the power, disconnect the power cord from 

the AC outlet and contact ETA Systems. Do not to attempt to continue operation of the device as this may cause fire or electric 

shock.

    •   Smoke or strange smell coming from the unit.
    •   If the device falls or the case is damaged.
    •   If water or any metallic objects falls into the device.
    •   If the power supply cord is damaged in any way.
    •   If the device is malfunctioning.
  •   Do not insert or drop metallic objects or flammable materials into the ventilation holes of the device’s cover, as this may result in 

electric shock or fire.

  •   Do not place any containers with liquid or metallic objects on the top of the device. 

 

If any liquid spills into the unit, fire or electric shock may result.

  •   Never operate this device or touch the power supply cord during an electrical storm, electric shock may result.
  •   Never exceed the wattage on the product when connecting equipment. Fire and/or property damage may result.
  •   Operate the device only with the voltage specified on the unit. Fire and/or electric shock may result if a higher voltage is used.
  •   Do not modify, kink, or cut the power cord. Do not place the power cord in close proximity to heaters and do not place heavy 

objects on the power cord, including the device itself, doing so may result in fire or electrical shock.

  •   Ensure that the safety ground terminal is connected to a proper ground. Never connect the ground to a gas pipe as a catastrophic 

disaster may result.

  •   Be sure the installation of the product is stable, avoid slanted surfaces as the product may fall and cause injury or property 

 

damage.

CAUTION – WHEN THE DEVICE IS IN USE

 

  •   Never place heavy objects on the product, causing it to fall and/or break, resulting in personal injury and property damage. In addi

-

tion, the product itself may fall and cause injury and property damage.

  •   Contact ETA Systems for instructions on cleaning the inside of the unit. Large accumulations of dust inside the unit may result in 

heat buildup and fire.

  •   Ensure that the power supply plug is securely plugged into the wall outlet. Never allow dust to accumulate on the power plug or 

inside the wall outlet.

  •   When cleaning the unit or the unit is not to be operated for an extended time period, unplug the power cord from the wall.

ETA-S15 

Power Conditioner & Distribution Unit

Summary of Contents for ETA-S15

Page 1: ...ifications are subject to change without notice 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 ETA S15 Power Conditioner Distribution Unit ETA S15 Power Conditioner Distribution Unit ...

Page 2: ...lvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 TABLE OF CONTENTS Safety Instructions 3 Introduction 5 Key Features 5 Applications 5 Front Panel Features 6 Rear Panel Features 6 Installation 6 Specifications 7 Warranty 8 ETA S15 Power Conditioner Distribution Unit ...

Page 3: ...ng type power outlet This is a safety feature If you are unable to insert the plug into the outlet con tact your electrician to replace your obsolete outlet Do not defeat the safety purpose of the grounding type plug 14 Unplug this device during lightning storms or when unused for long periods of time 15 Refer all servicing to qualified service personnel Servicing is required when the device has b...

Page 4: ...esult in electric shock or fire Do not place any containers with liquid or metallic objects on the top of the device If any liquid spills into the unit fire or electric shock may result Never operate this device or touch the power supply cord during an electrical storm electric shock may result Never exceed the wattage on the product when connecting equipment Fire and or property damage may result...

Page 5: ...eaks of 3000A These spikes are very fast and usually only last for a very short period of time The ETA S15 s circuitry is very fast and can suppress unwanted energy within a nanosecond response and sustain the suppression up to 2 milliseconds thus ensuring virtually trouble free protection The ETA S15 offers power management control noise filtering and spike surge protection making it the most com...

Page 6: ...nate when in the On position REAR PANEL FEATURES 1 AC Mains Input Connect the 9 3m power cord to a 15A 120VAC outlet to provide power to the ETA S15 2 AC Switched Power Outlets These six outlets are Live when the front panel power switch is activated 3 AC Unswitched Power Outlets These two outlets are always Live when the ETA S15 is plugged into a 120VAC source INSTALLATION Before installing we st...

Page 7: ...nical Data Current Rating 15 amps Operating Voltage 102VAC 132VAC Min Spike Clamping Voltage 460VRMS 3 000A Max Spike Clamping Voltage 6000V Max Spike Clamping Resp Time 1 Nanosecond Spike Clamping Voltage 100A 1250Vp for 20µs Maximum Surge Current 6 500A Energy Rating 2ms 200 Joules Noise Attenuation EMI RFI 10dB 10kHz 40dB 100kHz 100dB 10MHz Temperature Range 5 35 c Humidity Range 5 to 95 R H Me...

Page 8: ...en products returned to ETA Systems do not qualify for repair or replacement under our warranty repairs may be performed at prevailing costs for material and labor unless there is included with the returned product s a written request for an estimate of repair costs before any non warranty work is performed In the event of replacement or upon completion of repairs return shipment will be made with...