WHEN THE DEVICE IS IN USE

  

 

•  To prevent electric shock, do not remove the product cover as there are high voltage components inside. Refer all servicing to  
 

ETA Systems. 

•  Should any of the following irregularities occur during use, immediately switch off the power, disconnect the power cord from the  
 

AC outlet and contact ETA Systems. Do not to attempt to continue operation with the product as this may cause fire or electric   

 shock:
 

•  Smoke or strange smell coming from the unit.

 

•  If the product falls or the case is damaged.

 

•  If water or any metallic objects falls into the product.

 

•   If the power supply cord is damaged in any way.

 

•  If the unit is malfunctioning.

• 

Do not insert or drop metallic objects or flammable materials into the ventilation holes of the product's cover, as this may result in  

 

electric shock or fire.

• 

Do not place any containers with liquid or metallic objects on the top of the product. If any liquid spills into the unit, fire or electric  

 

shock may result.

• 

Never operate this product or touch the power supply cord during an electrical storm, electric shock may result.

• 

Never exceed the power rating on the product when connecting equipment. Fire and/or property damage may result. 

• 

Operate the product only with the voltage specified on the unit. Fire and/or electric shock may result if a higher voltage is used. 

• 

Do not modify, kink, or cut the power cord. Do not place the power cord in close proximity to heaters and do not place heavy objects  

 

on the power cord, including the product itself, doing so may result in fire or electrical shock.

• 

Ensure that the safety ground terminal is connected to a proper ground. Never connect the ground to a gas pipe as a catastrophic  

 

disaster may result. 

• 

Be sure the installation of the product is stable, avoid slanted surfaces as the product may fall and cause    

 

 

 

injury or property damage.

 

WHEN INSTALLING THE PRODUCT

 

•   Plugging in or unplugging the power cord with wet hands may result in electric shock. 
•  Never move the unit with the power cord plugged into the wall, as damage to the power cord may result.  
•  When unplugging the cord from the wall, grasp the plug, NOT the cord. 
•  Never install this product in humid or dusty locations, nor in direct sunlight, near sources of heat, or in areas where sooty smoke or  
 

steam are present. Fire and electric shock may result.

•  Keep all sides of the unit at least 3

1

2

" away from objects that may obstruct air flow to prevent the unit's internal temperature rise.

 

WHEN THE PRODUCT IS IN USE

 

•  Never place heavy objects on the product, causing it to fall and/or break, resulting in personal injury and property damage. In    
 

addition, the product itself may fall and cause injury and property damage. 

•  Contact ETA Systems for instructions on cleaning the inside of the unit. Large accumulations of dust inside the unit may result in heat  
 

buildup and fire. 

•  Ensure that the power supply plug is securely plugged into the wall outlet. Never allow dust to accumulate on the power plug or  
 

inside the wall outlet. 

•  When cleaning the unit or the unit is not to be operated for an extended period, unplug the power cord from the wall.

CAUTION 

WARNING

CAUTION 

Summary of Contents for ETA-PD8A

Page 1: ...tions are subject to change without notice 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 ETA PD8A AC Power Conditioner Distribution Unit ETA PD8A AC Power Condit...

Page 2: ...elephone 800 321 6699 Fax 800 996 3821 ETA PD8A AC Power Conditioner Distribution Unit TABLE OF CONTENTS Important Safety Instructions 3 Introduction 5 Key Features and Applications 6 Front Panel Desc...

Page 3: ...y with the cart stand tripod bracket or table specified by the manufacturer or sold with the device When a cart is used use caution when moving the cart device combination to avoid injury from tip ove...

Page 4: ...r cord Do not place the power cord in close proximity to heaters and do not place heavy objects on the power cord including the product itself doing so may result in fire or electrical shock Ensure th...

Page 5: ...ference The ETA PD8A is unique in that the integrator can select the power cord length that is required for the installation A removable 12 IEC power cord with a retainer bracket is supplied with the...

Page 6: ...rcuit Breaker Protection 15A Spike Suppression up to 6000V AC Fault Indicator Ground Status Indicator Removable IEC Power Cord with a Retainer Bracket APPLICATIONS The ETA PD8A was designed to be flex...

Page 7: ...rotection circuit is functioning correctly and the connected equipment is protected from voltage transients Although the clamping suppression circuit virtually assures protection from most transient v...

Page 8: ...iner bracket installation 3 AC Mains Power Breaker The 15A rated breaker will open if the combined draw of all AC outlets exceeds 15A Note The breaker is designed to exceed its rating for a short peri...

Page 9: ...ake sure the 15A outlet is properly inspected by a certified electrician prior to connecting the ETA PD8A Make sure to inspect the equipment that will be connected to the ETA PD8A to ensure it does no...

Page 10: ...ETAsys com Specifications are subject to change without notice 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 ETA PD8A AC Power Conditioner Distribution Unit NOT...

Page 11: ...ket 15A 1800W Circuit Breaker 15A Resettable Technical Data Max AC Mains Current 15A AC Mains Breaker Operating Voltage 102VAC 132VAC Power Consumption 6 Watts Min Spike Clamping Voltage 460 VRMS 3 00...

Page 12: ...forth below When products returned to ETA Systems do not qualify for repair or replacement under our warranty repairs may be performed at prevailing costs for material and labor unless there is includ...