ETA-ECS3 

Power Sequencer & Conditioner

INTRODUCTION

Thank you for purchasing the ETA Systems ETA-ECS3 AC Power Sequencer and Conditioner. The ETA-ECS3 has been designed to 
meet most installation requirements for AC power distribution and equipment power protection. The 15A compact 1RU unit features 
three sequential timing sections that can be activated via the unit, or remotely. Front panel activation is via a momentary switch, while 
rear activation is via a momentary contact closure, or by 5-24VDC trigger feed. AC Mains Voltage can be monitored via the front panel 
from the precision Digital Volt Meter. To light your rack, the ETA-ECS3 has incorporated a front panel pull-out dimmable LED tube light. 
The rear of the rack can be illuminated by the optional Atlas Power 16" gooseneck LED lamp, AP-GNL18, connected via an XLR style 
socket. LED lamps are far superior in longevity along with heat reduction when compared to traditional incandescent lamps and the 
XLR base mounts are also superior to the commonly used BNC type base. If a 15A AC Mains power source is not enough to meet the 
amperage demand of your system, the ETA-ECS3 provides a sequenced 12VDC output that can be used to trigger other devices such 
as the ETA Systems ETA-20SH 20A stand alone AC power module.

The ETA-ECS3 also features noise filtering for unwanted Radio Frequency Interference (RFI) that are commonly introduced into the AC 
lines by nearby radio transmitters or wireless products. EMI filters are incorporated to reduce noise from Electromagnetic Interference 
(EMI) from such items as electric motors and switching power supplies. The benefit of these filters can be seen on video products or 
audibly by reducing static pops and external signal interference. 

Unstable AC Mains voltage is one of the main reasons for equipment failure. AC Spikes, or Transients, are commonly caused by light-
ning storms or utility power plant grid switchovers. The amount of energy that can be injected into the power system can be immense 
with voltages reaching 6kV or amperage peaks of 3000A. These spikes are very fast and usually only last for a very short period of 
time. To protect against this potential problem, the ETA-ECS3 features Dual Clamping Suppression technology (DCS). If a spike intrudes 
the AC system, the ETA-ECS3 incoming AC Mains has special suppression circuitry to eliminate the unwanted energy and in the 
unlikely event of any energy getting passed the first stage, each sequenced output section has redundant DCS circuitry clamping the 
unwanted energy. This circuitry is very fast and can suppress unwanted energy within a nanosecond, while sustaining the suppression 
up to 2 milliseconds, thus ensuring virtually trouble free protection. 

High and low AC Main line voltages are another major contributor to equipment failures. High line can also be known as surges.  
Surges usually are a slower steady state rise in voltages ranging from 128VAC and up. They can be caused from fluctuations from the 
utility company’s power lines or industrial equipment turning on and off on the same power leg of the building’s incoming AC. Low line 
is also known as brownouts. This happens when the AC Mains drops below 107VAC. Most of the time it is caused by the utility com-
pany not being able to supply enough power during heavy utility consumption time periods, such as heat waves. Another factor would 
be from voltage drops in AC lines due to long transmissions.  The ETA-ECS3 will not only inform you if one of these conditions occurs, 
but under extreme variances in the AC Mains, it will shut the power to the equipment off. The Abnormal Voltage indicator on the front 
panel will flash if the AC Mains is between 101VAC and 107VCA or 128VAC and 132VAC. This is to inform you that a surge occurred 
and may have damaged voltage sensitive equipment. If an extreme voltage swing occurs below 101VAC or above 132VAC, the  
ETA-ECS3 Extreme Voltage Shutdown (EVS) protection circuit will automatically activate and turn all outlets off until it is manually reset. 

The ETA-ECS3 offers sequenced power management control, along with noise filtering and spike/surge protection making it the most 
compact, effective power management protection system on the market today. 

Summary of Contents for ETA-ECS3

Page 1: ...om Specifications are subject to change without notice 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 ETA ECS3 Power Sequencer Conditioner ETA ECS3 Power Sequencer Conditioner ...

Page 2: ...9 U S A Telephone 800 321 6699 Fax 800 996 3821 ETA ECS3 Power Sequencer Conditioner TABLE OF CONTENTS Important Safety Instructions 3 Introduction 5 Key Features 6 Applications 6 Front Panel 7 Rear Panel 9 Installation 10 Troubleshooting 10 AC Power Cord Retainer System 11 Specifications 12 Warranty 16 ...

Page 3: ...ination to avoid injury from tip over 13 This product is equipped with a three wire grounding type plug a plug having a third grounding pin This plug will only fit into a grounding type power outlet This is a safety feature If you are unable to insert the plug into the outlet contact your electrician to replace your obsolete outlet Do not defeat the safety purpose of the grounding type plug 14 Unp...

Page 4: ...g so may result in fire or electrical shock Ensure that the safety ground terminal is connected to a proper ground Never connect the ground to a gas pipe as a catastrophic disaster may result Be sure the installation of the product is stable avoid slanted surfaces as the product may fall and cause injury or property damage Installation of this product must be done by a certified electrician for a ...

Page 5: ... energy that can be injected into the power system can be immense with voltages reaching 6kV or amperage peaks of 3000A These spikes are very fast and usually only last for a very short period of time To protect against this potential problem the ETA ECS3 features Dual Clamping Suppression technology DCS If a spike intrudes the AC system the ETA ECS3 incoming AC Mains has special suppression circu...

Page 6: ...on 15A Indicated by Breaker Open Indicator Front Mounted Pull out LED Light With 2 Position Dimmer Rear Mounted XLR Connector for 12VDC LED Lamp Lamp sold separately Atlas Power model AP GNL18 External Switch Sequence Trigger Activation External DCV Sequence Trigger Activation 5 24VDC 12VDC Sequence Trigger Output for Optional External AC Outlet AC Power Cord Retainer APPLICATIONS The ETA ECS3 was...

Page 7: ...tion circuitry but will not be shut off by the EVS circuit 2 AC Mains Breaker The 15A rated breaker will open if the combined continuous current draw of all AC outlets exceeds 15A Note In audio applications peak current demands commonly exceed the continuous current ratings on AC outlets Note The breakers are designed to exceed their rating for a short period of time If the breaker is tripped to r...

Page 8: ...hes under several AC Mains fault situations that are listed below Normal operating voltages for AC Mains voltage is considered to be between 108VAC and 125VAC Any voltages exceeding those parameters are considered a risk to damage equipment plugged into the ETA ECS3 High AC Line Mains The Abnormal Voltage LED will flash between 128VAC 132VAC indicating possible damage may occur to equipment due to...

Page 9: ...nalog filter outlets If more high power outlets are needed or if 15A is not enough current to support your power requirements you can use the 24VDC trigger to activate an additional power outlet such as the ETA 20SH Contact ETA Systems for AC outlet options 5 XLR Light Socket A 12VDC XLR light socket is to provide power for the optional Atlas Power AP GNL18 light 6 Light Socket Power Switch This s...

Page 10: ...l Voltage indicator is illuminated the Volt Meter is Flashing and you hear a buzzer from the unit Possible Cause The AC Mains Voltage exceeded 132VAC or the voltage dropped below 101VAC Action Needed Measure the AC mains before the ETA ECS3 If the voltage is between 117VAC and 123VAC you may proceed to reset the ETA ECS3 by restarting the start up sequence Note It is important to have all equipmen...

Page 11: ...st be done by a certified electrician for a permanently connected apparatus provided neither with an all pole mains switch nor an all pole circuit breaker A readily accessible disconnect device shall be incorporated in the building installation power wiring The installation shall be carried out in accordance with all applicable installation rules in accordance with all applicable federal state and...

Page 12: ...08mm Type Connector DC Output 12VDC 100mA Output Paralleled to Sequencer Section 3 Timing LED Light Socket XLR Socket to Provide 12VDC for Optional 16 Gooseneck Lamp AP GNL18 LED Light Switch Two Position On Off Grounding Terminal Hand Screw Type Terminal to Chassis Ground AC Mains Power Cord 9 3 Meters 14 gauge Technical Data Current Rating 15 amps Power Consumption 12 watts Operating Voltage 102...

Page 13: ... 13 ETAsys com Specifications are subject to change without notice 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 ETA ECS3 Power Sequencer Conditioner NOTES ...

Page 14: ... 14 ETAsys com Specifications are subject to change without notice 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 ETA ECS3 Power Sequencer Conditioner NOTES ...

Page 15: ... 15 ETAsys com Specifications are subject to change without notice 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 ETA ECS3 Power Sequencer Conditioner NOTES ...

Page 16: ... below When products returned to ETA Systems do not qualify for repair or replacement under our warranty repairs may be performed at prevailing costs for material and labor unless there is included with the returned product s a written request for an estimate of repair costs before any non warranty work is performed In the event of replacement or upon completion of repairs return shipment will be ...

Reviews: