4
located on the aluminum alloy frame, are provided for ease of installation. They are
designed to be used with metric M6×1(Torque 12 Lb-in) stainless steel screws.
Mounting with Bolts
•
The module must be attached and supported by at least four bolts through the
indicated mounting holes.
•
Most installations will use the four inner mounting holes on the module frame.
•
Depending on the local wind and snow loads, additional mounting points may be
required.
Mounting with Clamps
•
If module clamps are used to secure the module, the torque on the clamp bolt
should be around 8–10 Nm.
•
A minimum of four module clamps should be used, two on each long frame side,
in the general clamping areas denoted by the wide arrows on the drawing.
•
Depending on the local wind and snow loads, additional module clamps may be
required.