ESYLUX EB10430404 Detailed Operating Instructions Download Page 11

OPERATING INSTRUCTIONS

11 / 17

GB

MD 360/8 Basic

MD 360i/24 Basic

MD 360/24 Basic SMB

MD 360i/8 Basic

MD 360/8 Basic SMB

MD 360i/24 Basic SMB

MD 360/24 Basic

MD 360i/8 Basic SMB

Function

Customised setting

Detector LEDs ON / OFF

The LEDs in the detector can be switched on or off.

Acknowledgement:
LEDs OFF:

 The 

red LED

 is switched off for approx. 2 seconds. 

LEDs ON:

 The 

red LED

 flashes three times.

Reset

The remote control settings are reset and the detector uses the manual 
potentiometer values. 

Acknowledgement:

 The 

red LED

 flashes three times.

6.6 

Mobil-PDi/MDi-universal (EP10433993)

 

6.7 

Mobil-PDi/MDi-universal temporary settings

Parameter configurations are only temporarily applied.

Function

Customised setting

PDi/MDi

Remote control
Functions
Channel 1
Channel 2
System

Bat ok 

LS 

MDi

Selecting remote control:

Summary of Contents for EB10430404

Page 1: ...om www esylux com Detailed operating instructions MD 360 8 Basic EB10430404 MD 360i 8 Basic EB10430428 MD 360 24 Basic EB10430848 MD 360i 24 Basic EB10430862 MD 360 24 Basic SMB EB10430886 MD 360i 24...

Page 2: ...hing delay not in pulse mode 4 4 Installation connection 5 4 1 Masking the field of detection 7 5 Activation 7 5 1 Overview of factory settings 7 6 Settings 8 6 1 Control via external S button 8 6 2 C...

Page 3: ...must not be changed modified or painted doing so will void any warranty claims You must check the device for damage immediately after unpacking it If there is any damage you should not install the de...

Page 4: ...wo short flashes of the red LED the LED can be switched off see Configuring parameters via remote control Once the lighting has been switched on the sensor deactivates light measurement for this perio...

Page 5: ...360i 8 Basic SMB 4 Installation connection Note Switch off the power supply before installing the system The detectors can be flush mounted or surface mounted and are also suitable for recessed ceilin...

Page 6: ...ring the detector head on approaches to the detector are more difficult to detect and therefore the range of the detector is significantly reduced The detector should be positioned depending on the av...

Page 7: ...c areas of detection 5 Activation Connect the power supply A warm up phase of 25 seconds is initiated The red LED flashes During this time the lighting is switched on 5 1 Overview of factory settings...

Page 8: ...e duration of the switch off delay time Press button for approx 3 second The lighting is switched on or off continuously for 4 hours Further parameters can be configured via remote control Remote cont...

Page 9: ...flash of the red LED Reset settings Temporarily set values are cleared and the detector returns to the manually preset operating mode 4h ON OFF The lighting is switched on or off continuously for app...

Page 10: ...lux value and movement being detected If movement is no longer detected the preset switch off delay time will start The relevant active status can be optionally overridden using the external S button...

Page 11: ...The red LED is switched off for approx 2 seconds LEDs ON The red LED flashes three times Reset The remote control settings are reset and the detector uses the manual potentiometer values Acknowledgeme...

Page 12: ...g the Reset function ON acknowledgement Movement detected in the field of detection is acknowledged with one short flash of the red LED OFF acknowledgement Movement detected in the field of detection...

Page 13: ...ing Functions ON OFF Test Reset 4 h ON OFF Bat ok LS MDi Take a reading of the current ambient light value The detector switches the lighting on if the target brightness value is below the preset lux...

Page 14: ...ntrol settings are reset and the detector uses the manual potentiometer values Acknowledgement The red LED flashes three times Channel 1 Read in Light Time Reset LEDs ON OFF Fully semi automatic Bat o...

Page 15: ...interference in the field of detection such as heating air conditioning or moving objects e g curtains by open windows The switch off delay time has been set too short Lighting is switched off during...

Page 16: ...ntain any components that require maintenance The device can only be replaced as a complete unit Note This device must not be disposed of as unsorted household waste Used devices must be disposed of c...

Page 17: ...erference caused by environmental factors or damage in transit nor to damage caused as a result of failure to follow the user or maintenance instructions and or as a result of improper installation An...

Reviews: