GB
30 / 34
MA01709900
Manual control via push button
8.
Manual control via push button
The twilight switch is equipped with a connection for an external push
button (S terminal, for information on connection see chapter
Standard operation with additional control using a push button" on page
18
). This means that the twilight switch can be manually overridden at
any time so that the lighting can be switched on or off individually.
The twilight switch switches the lighting
on
until …
•
the brightness level exceeds the set switching value
or
•
Until an external push button is pressed again
The twilight switch switches the lighting
off
until …
•
the brightness level falls below the set switching value
or
•
Until an external push button is pressed again
You can send the following temporary commands using the external push
button:
¾
Briefly press (< 1 second) the push button once.
9
The lighting is switched on or off.
¾
Briefly press (< 1 second) the push button
twice within 4 seconds.
9
The lighting is switched on or off for
4 hours continuously.
¾
Briefly press (< 1 second) the push button
three times within 4 seconds.
9
The lighting is switched on or off for
12 hours continuously.
To cancel a temporary command, briefly press the push button once or
select the following setting in the ESY Control app
).
Switching on
lighting manually