background image

19

T

TT

T

Tur

ur

ur

ur

urnout number

nout number

nout number

nout number

nout number

Addr

Addr

Addr

Addr

Address

ess

ess

ess

ess

CV1

CV1

CV1

CV1

CV1 CV9

CV9

CV9

CV9

CV9

1

2

3

4

1

1

0

5

6

7

8

2

2

0

9

10

11

12

3

3

0

13

14

15

16

4

4

0

17

18

19

20

5

5

0

21

22

23

24

6

6

0

25

26

27

28

7

7

0

29

30

31

32

8

8

0

33

34

35

36

9

9

0

37

38

39

40

10

10

0

41

42

43

44

11

11

0

45

46

47

48

12

12

0

49

50

51

52

13

13

0

53

54

55

56

14

14

0

57

58

59

60

15

15

0

61

62

63

64

16

16

0

65

66

67

68

17

17

0

69

70

71

72

18

18

0

73

74

75

76

19

19

0

77

78

79

80

20

20

0

81

82

83

84

21

21

0

85

86

87

88

22

22

0

89

90

91

92

23

23

0

93

94

95

96

24

24

0

97

98

99

100

25

25

0

101

102

103

104

26

26

0

105

106

107

108

27

27

0

109

110

111

112

28

28

0

113

114

115

116

29

29

0

117

118

119

120

30

30

0

121

122

123

124

31

31

0

125

126

127

128

32

32

0

129

130

131

132

33

33

0

133

134

135

136

34

34

0

137

138

139

140

35

35

0

141

142

143

144

36

36

0

145

146

147

148

37

37

0

149

150

151

152

38

38

0

153

154

155

156

39

39

0

157

158

159

160

40

40

0

161

162

163

164

41

41

0

165

166

167

168

42

42

0

169

170

171

172

43

43

0

173

174

175

176

44

44

0

177

178

179

180

45

45

0

181

182

183

184

46

46

0

T

TT

T

Tur

ur

ur

ur

urnout number

nout number

nout number

nout number

nout number

Addr

Addr

Addr

Addr

Address

ess

ess

ess

ess

CV1

CV1

CV1

CV1

CV1 CV9

CV9

CV9

CV9

CV9

185

186

187

188

47

47

0

189

190

191

192

48

48

0

193

194

195

196

49

49

0

197

198

199

200

50

50

0

201

202

203

204

51

51

0

205

206

207

208

52

52

0

209

210

211

212

53

53

0

213

214

215

216

54

54

0

217

218

219

220

55

55

0

221

222

223

224

56

56

0

225

226

227

228

57

57

0

229

230

231

232

58

58

0

233

234

235

236

59

59

0

237

238

239

240

60

60

0

241

242

243

244

61

61

0

245

246

247

248

62

62

0

249

250

251

252

63

63

0

253

254

255

256

64

0

1

257

258

259

260

65

1

1

261

262

263

264

66

2

1

265

266

267

268

67

3

1

269

270

271

272

68

4

1

273

274

275

276

69

5

1

277

278

279

280

70

6

1

281

282

283

284

71

7

1

285

286

287

288

72

8

1

289

290

291

292

73

9

1

293

294

295

296

74

10

1

297

298

299

300

75

11

1

301

302

303

304

76

12

1

305

306

307

308

77

13

1

309

310

311

312

78

14

1

313

314

315

316

79

15

1

317

318

319

320

80

16

1

321

322

323

324

81

17

1

325

326

327

328

82

18

1

329

330

331

332

83

19

1

333

334

335

336

84

20

1

337

338

339

340

85

21

1

341

342

343

344

86

22

1

345

346

347

348

87

23

1

349

350

351

352

88

24

1

353

354

355

356

89

25

1

357

358

359

360

90

26

1

361

362

363

364

91

27

1

365

366

367

368

92

28

1

T

TT

T

Tur

ur

ur

ur

urnout number

nout number

nout number

nout number

nout number

Addr

Addr

Addr

Addr

Address

ess

ess

ess

ess

CV1

CV1

CV1

CV1

CV1 CV9

CV9

CV9

CV9

CV9

369

370

371

372

93

29

1

373

374

375

376

94

30

1

377

378

379

380

95

31

1

381

382

383

384

96

32

1

385

386

387

388

97

33

1

389

390

391

392

98

34

1

393

394

395

396

99

35

1

397

398

399

400

100

36

1

401

402

403

404

101

37

1

405

406

407

408

102

38

1

409

410

411

412

103

39

1

413

414

415

416

104

40

1

417

418

419

420

105

41

1

421

422

423

424

106

42

1

425

426

427

428

107

43

1

429

430

431

432

108

44

1

433

434

435

436

109

45

1

437

438

439

440

110

46

1

441

442

443

444

111

47

1

445

446

447

448

112

48

1

449

450

451

452

113

49

1

453

454

455

456

114

50

1

457

458

459

460

115

51

1

461

462

463

464

116

52

1

465

466

467

468

117

53

1

469

470

471

472

118

54

1

473

474

475

476

119

55

1

477

478

479

480

120

56

1

481

482

483

484

121

57

1

485

486

487

488

122

58

1

489

490

491

492

123

59

1

493

494

495

496

124

60

1

497

498

499

500

125

61

1

501

502

503

504

126

62

1

505

506

507

508

127

63

1

509

510

511

512

128

0

2

513

514

515

516

129

1

2

517

518

519

520

130

2

2

521

522

523

524

131

3

2

525

526

527

528

132

4

2

529

530

531

532

133

5

2

533

534

535

536

134

6

2

537

538

539

540

135

7

2

541

542

543

544

136

8

2

545

546

547

548

137

9

2

549

550

551

552

138

10

2

Figure 12: Turnout number, adresses & CVs of the first 552 turnouts

Summary of Contents for 51800

Page 1: ...1 SwitchPilot P N 04708 07029 User manual Third edition October 2008 51800 SwitchPilot 51801 SwitchPilot Extension 51802 SwitchPilot Servo...

Page 2: ...the transistor outputs 12 6 7 1 Connecting double coil solenoids 12 6 7 2 Wiring of daylight signals and light bulbs or LEDs 13 6 7 3 Wiring of a motor drive 13 6 8 Wiring of a servo 14 6 9 Wiring of...

Page 3: ...collection service or the dealer shop where you purchased this product 10 3 Configuration of servo speed 22 10 4 Configuration of servo outputs with input unit 22 11 RailCom 11 RailCom 11 RailCom 11...

Page 4: ...which will gradually show you how to operate the products 51800 51801 and 51802 Chapter 5 includes an overview of the features of the single SwitchPilot decoders In chapter 7 we deal with the connecti...

Page 5: ...nt price performance ratio Introduction The SwitchPilot family 5 1 1 SwitchPilot overview SwitchPilot SwitchPilot Servo DCC mode Ok Ok Motorola mode Ok Ok DCC programming Ok Ok 4 double transistor out...

Page 6: ...the side of the SwitchPilot and receive its power from it Each SwitchPilot Extension module has 4 by 2 relay outputs that are operated in parallel to the corresponding outputs of the SwitchPilot This...

Page 7: ...pulse duration then the output is switched off even though the button is still pressed The limitation of the pulse duration helps avoid damage to solenoids The pulse duration can be set in such a way...

Page 8: ...hed the terminals I and Com of the relay output are connected Is output B on the SwitchPilot active or servo setting B is reached the terminals II and Com are connected 5 2 5 Feedback inputs SwitchPil...

Page 9: ...ot Extension mechanically and electrically z Decoder ground optional needed for turnout operation when using the SwitchPilot without a digital control unit 6 2 Connecting elements of the SwitchPilot E...

Page 10: ...Input unit with a and buttons and monitor LEDs 1 directly Servo end positions A and B and the rotation speed set l Monitor LEDs During the setup of Servo end position and rotational speed on the input...

Page 11: ...5 6 5 Separate power supply For larger layouts with many devices controlled by SwitchPilots and simultaneously active we recommend to utilise a separate power supply in this manner the power for swit...

Page 12: ...be as desired in other words if straight and diverging route are exchanged simply swap the wires between terminals Out A and Out B SwitchPilot can also handle PECO turnouts However their current consu...

Page 13: ...ld have a rating of about 1 kohm to 2 2 kohm The screw terminal C of each output has positive potential Therefore the cathode of the LEDs must be connected to the terminals Out A respectively Out B 6...

Page 14: ...s SwitchPilot The SwitchPilot can report the actual aspect or position of the turnout to the command station via RailCom The turnout must have some extra contacts for this Figure 6 on page 9 illustrat...

Page 15: ...abinet In order to find the indivi dual index cards each one has a number or description with the property of the card e g Loco Address or Maximum Speed Now imagine that those cards can be written on...

Page 16: ...der 10 write value 1 into CV 3 The decoder address must be known The reading of CV values is not possible in this case It is possible to read out CVs on the main track with RailCom More information ca...

Page 17: ...Digital Plus V3 Unfortunately Digitrax units do not supply enough current on the programming output ZIMO units sometimes report an over current Therefore use the main track programming 7 2 1 7 3 Progr...

Page 18: ...assigned to it Programming SwitchPilot Since the SwitchPilot has a total of six outputs two addresses can be assigned to it address 1 is responsible for the transistor outputs 1 4 address 2 is for th...

Page 19: ...6 2 1 265 266 267 268 67 3 1 269 270 271 272 68 4 1 273 274 275 276 69 5 1 277 278 279 280 70 6 1 281 282 283 284 71 7 1 285 286 287 288 72 8 1 289 290 291 292 73 9 1 293 294 295 296 74 10 1 297 298 2...

Page 20: ...may now release the button the decoder is in learning mode 5 Now switch the turnout you have selected in step 1 on your handheld controller or your command station It is immaterial whether you switch...

Page 21: ...blinker If you wish to set the two transistor outputs into the alternating blinking mode for instance for levels crossings then write a value between 32 and 64 into the CV This value describes the du...

Page 22: ...rogramming button b programming LED c button d button e LED servo 1 4 All changes are executed immediately when using the input unit for configuration To test your settings all servos should be proper...

Page 23: ...whether the data actually arrived or not The following information can be sent from the SwitchPilot decoder to the central unit CV Information The decoder can return all CV values to the central unit...

Page 24: ...as follows RailCom Go to the menu New Solenoid Device Under data format choose DCC with RailCom Choose the desired symbol and enter the turnout number in our case 14 Now connect the solenoid device w...

Page 25: ...command But this can lead to a short at the frog polarization because the turnout tongue remains at the previous position for a while The behavior can be changed in such a way that the relays only swi...

Page 26: ...set 15 Support and assistance Your model train dealer or hobby shop is your competent partner for all questions regarding your SwitchPilot decoder In fact he is your competent partner for all question...

Page 27: ...feedback reports turnout status via the tracks and can be displayed on ECoS amongst others Dimensions in mm app 86mm x 86mm x 25mm 16 2 Technical data SwitchPilot Servo Operational modes NMRA DCC Acce...

Page 28: ...ternately active 32 63 blinker Duration of On status multiple of 130 msec Bi stable k84 compatable either Out A or Out B 64 is active variable 4 Configuration output 2 Describes the properties of deco...

Page 29: ...RailCom communication is switched off 0 RailCom communication is permitted 8 7 Decoder is DCC Accessory Decoder read only cannot be reprogramed 128 33 Function output status Current status of functio...

Page 30: ...tore the address Value 8 in CV36 switches off the second address factory setting 37 Servo 1 rotation speed Running time speed of servo 1 from one end position to the following 0 63 15 The running time...

Page 31: ...arranty certificate together with the receipt from your ESU dealer serves as proof of purchase We recommend keeping the warranty certificate together with the receipt In case of a claim please fill in...

Page 32: ...4 Short circuit Servo outputs Dead On Arrival no function right out of the box No function anymore Programming on programming track 3 Description of fault add extra page if necessary 4 Receipt of paym...

Reviews: