ESTOM AS1-GSM Installation And User Manual Download Page 6

 

6

6 LED 

indications 

LED Color 

 

GSM OK 

green 

Is lit if the unit is connected to the network and field strength 
is appropriate. 
Appropriate field strength: 2 (on the scale of 0-5) 

GSM / SIM ERROR

 

red 

Is lit continuously if the unit is not connected to the network. 
The following cases are possible: 
- the GSM antenna is not connected or is faulty 
- the SIM card is not inserted, or PIN code request is not 
deactivated, or the card is faulty. 

CALL IN PROGRESS

 

green  Call or conversation is in progress. 

VOLTAGE OUT

 

red 

Voltage output activated (e.g. electric lock control) 

RELAY CONTROL

 

red 

Relay output activated (e.g. gate control) 

 

7 Installation 

7.1 Mounting 

  Measure the GSM

 

signal with your mobile phone. It may happen that in the

 

desired place of 

installation the

 

signal strength

 

is not satisfactory. In this case you can move the unit or the 

GSM antenna in a more suitable place before installation. 

  Do not mount the unit where it could be affected by strong electromagnetic disturbances. 

  Do not mount the unit in wet places or in places with a high degree of humidity. 

  Connecting the antenna: the GSM antenna can be connected to the SMA connector. The 

antenna supplied with the unit provides good transmission under normal reception 
circumstances. In case of having signal strength problems or/and wave interference (fading), 
use other type of antenna or find a more suitable place for the unit. 

  Inserting the SIM card: turn the SIM card with the metallic contact surface downwards 

towards the panel, and the cut corner should point towards the panel’s center. Insert the 
card in this position in the socket and press until it clicks. To remove the SIM card, push it 
towards the socket then pull it out.  

7.2  Putting into operation 

  Disable PIN code request, voicemail and missed call notification service on the SIM card. 

  Enable caller identification and caller ID sending service on the SIM card at the GSM service 

provider. 

  Make sure the SIM card is inserted properly into its socket. 

  Make sure the antenna is fixed properly into the SMA connector. 

  Make sure the wiring is done as shown in the wiring diagram. 

  Power up the unit (12-24V AC/ DC). Make sure the power supply is sufficient for the 

operation of the unit. If operating from a 16V AC transformer, the necessary current is min. 
300mA (5VA). 

 
 

Summary of Contents for AS1-GSM

Page 1: ...AS1 GSM REV 1 1 01 02 2013 AS1 GSM GSM based intercom and access control Installation and user manual...

Page 2: ...3 Relay output control gate opening 4 4 4 Voltage output control electric lock activation 4 4 5 Forwarding incoming SMS messages 4 5 Settings 5 5 1 Response SMS explanation 5 6 LED indications 6 7 Ins...

Page 3: ...tive SIM card 1 Functions Intercom Listen in mode Electric door lock control via DTMF codes Electric gate control by free call SMS forwarding Programming through SMS message 2 Features GSM communicati...

Page 4: ...er s phone number e g 31 0036301234567 4 3 Relay output control gate opening The unit can activate an independent normally open relay output by free call using caller phone number identification Up to...

Page 5: ...00 seconds Default setting 60 seconds RTIME duration Duration of the relay output activation 1 100 seconds Default setting 3 seconds VTIME duration Duration of the voltage output OUT activation 1 100...

Page 6: ...h degree of humidity Connecting the antenna the GSM antenna can be connected to the SMA connector The antenna supplied with the unit provides good transmission under normal reception circumstances In...

Page 7: ...control 3 Relay output normally open contact max 24V DC 1A 4 Voltage output 12V DC 1A 5 Supply voltage input 14 24V AC DC 6 Speaker output 7 SIM card socket 8 GSM antenna connector SMA type 9 Status i...

Page 8: ...100mA Maximum consumption 400mA 12VDC 200mA 24VDC Max load of the relay output max 1A 24V DC Voltage output max load 12V DC max 1A Operating temperature 20 C 70 C Transmission frequency GSM 900 1800...