P
=
Speed
Pressure
Flow Rate
Temperature
Re
v.
-Nr
.:
IM
3
24
E
V
0.
1-
2020
-02
-24
-FW
816
Instruction Manual IM 324 E
Page 6
Phone: +49 6021- 45 807 - 0
Fax:
+49 6021- 45 807 - 20
Esters Elektronik GmbH
Hafenrandstr. 14 · D-63741 Aschaffenburg
eMail: [email protected]
Internet: http://www.esters.de
2.2
Output
2.3
Relays
2.4
Electrical values
2.5
Environmental influences
2.6
Display, housing, weight
O
UTPUT
4 - 20 mA = 0 - (x) Bm³/h, l/h, Bm³/min, l/min
(only Eco and Pro: Nm³/h, NL/h, Nm³/min, NL/min) flow rate
(freely programmable), input resistance 500 Ohm
K1:
Relay (NO) freely programmable
-
pulse output (0,1, 1 oder 10 oder 100 m³ per impulse,
freely programmable), counter output quantity or
-
limit value or
-
device status
K2:
Relay (NO) freely programmable
-
pulse output (0,1, 1 oder 10 oder 100 m³ per impulse,
freely programmable), counter output quantity or
-
limit value or
-
device status
A
CCURACY
± 0,05 % EW ± 1 Digit bei 23°C
P
OWER SUPPLY
24 V, DC ± 3 V
A
MBIENT TEMPERATURE
-10 bis +60°C
S
TORAGE TEMPERATURE
-20 bis +85°C
T
EST VOLTAGE
3 kV
H
UMIDITY CLASS
E-DIN 40040
E
LECTROMAGNETIC COMPATIBILITY
acc. to EN 50082-2
D
ISPLAY
4 rows à 20 characters
S
TANDARD HOUSING
WALL MOUNTING
dimensions: 151 mm (W) x 125 mm (H) x 60 mm (D)
material: polycarbonate UL 94 V0
protection class: IP 65
weight: approx. 600 g
H
OUSING OPTIONS
-
mounting parts for DIN rail mounting
-
fixing parts for direct mounting on gas flowmeter GD 300
(only NON ATEX applications)