Assembling The AA195PM Two Hole Outdoor Pole Mounting Kit 
 
The AA195PM mounting kit contains all hardware items required for pole mounting and weatherproofing the 
ESTeem for outdoor installations.  The ESTeem Model 195 series (195E & 195 Narrowband) and Horizon series 
modem together with the AA195PM mounting kit allows the modem to be directly mounted to a round pole 
between 1.25” and 2” in diameter.   Any pole larger that 2” in diameter will require banding through the Pole 
Mount Brackets.   
 
Step 1: Pole Mounting Kit Packaging 
 

a)

 

If you purchased an AA195PM mounting kit with your ESTeem modem, the kit will be packed in 
the same packing box as the modem (Figure 1).   

 
 
 
 
 
 

 

Figure 1: Pole Mounting Kit Packaging 

Summary of Contents for AA195PM

Page 1: ...le mounting and weatherproofing the ESTeem for outdoor installations The ESTeem Model 195 series 195E 195 Narrowband and Horizon series modem together with the AA195PM mounting kit allows the modem to be directly mounted to a round pole between 1 25 and 2 in diameter Any pole larger that 2 in diameter will require banding through the Pole Mount Brackets Step 1 Pole Mounting Kit Packaging a If you ...

Page 2: ... notice 415 North Quay Street Kennewick WA 99336 www esteem com Phone 509 735 9092 Fax 509 783 5475 Revised 01 July 2016 Step 2 Tools Required for Assembly Step 3 Parts Inventory a Remove the Pole Mounting Kit and be sure you have received the following Figure 2 Tools Required for Assembly Figure 3 Parts Inventory ...

Page 3: ...ield Attachment a Place the four 10 24 Pan Screws into the holes on the underside of the Heat Shield b Attach the Heat Shield over the top of the ESTeem modem sliding the screws through the holes on either side of the modem s casing Step 5 Pole Mounting Bracket Assembly a Insert one U bolt through one of the Pole Mounting Brackets b Repeat step a for second U bolt and Pole Mounting Bracket Figure ...

Page 4: ...embly with the exposed screws Assembly will fit width wise across the bottom of modem b Using a Philips Head Screwdriver through the access holes provided in the Heat Shield secure the Pole Mounting Bracket Assembly c Repeat steps a and b for the second Pole Mounting Bracket Assembly Step 7 Ethernet Cable Boot Assembly a Slide the Ethernet Cable Boot over anoutdoor rated CAT 5e Ethernet cable Cabl...

Page 5: ...s or Ethernet Serial see Step 12 a Feed the CAT 5e Ethernet connector through the Face Plate Cover b Secure the Ethernet Cable Boot over the hole in the Face Plate Cover c If only one Ethernet connector is needed secure the Weather Proof Boot for Antenna Port B over the second hole in the Face Plate Cover d Inside the Face Plate Cover route the CAT 5e Ethernet cable through the molded strain relie...

Page 6: ... to the modem s Ethernet port b Secure the Face Plate Cover to the modem with the attached thumb screw c Verify the weather proof seal on the Face Plate Cover is sealed against the outer rim of the case without any material showing Step 10 Antenna Connector Boot Installation a Attach the antenna connector boots as shown for either dual attached antennas or external antennas b You are now ready to ...

Page 7: ... Pole Mounting Brackets against pole facing the heat shield towards the sun s path Southern facing in Northern Hemisphere b Verify direct mount antennas are mounted in open air with the radio mounted at the top of the pole The antennas should not be against the pole itself or any surface for best operation c Place Pole Mount Clamps over the end of the U bolts securing with washer and nut on each e...

Page 8: ...t Cable Routing Double Ethernet Cables a Feed the CAT 5e Ethernet connectors through the Face Plate Cover b Secure the Ethernet Cable Boot over the hole in the Face Plate Cover c Repeat steps a and b for second Ethernet connector d Inside the Face Plate Cover route the CAT 5e Ethernet cables through the molded strain relief fins to secure the cable and provide strain relief for the connectors Figu...

Reviews: