Estate Swing 

IMPORTANT: Determining Correct Setback 

PUSH TO OPEN 

-

This operation is commonly used if you driveway slopes up

after the gate, preventing it from swinging in. This means the gate operator is 

mounted on the inside of the property and pushes your gate out away from the 

orooertv. 

In line with center of hinge 

Post 

Rear pivot point of gate opener 

Column 

Rear pivot point of gate opener 

There are 4 factors to keep in mind when finding the setback mounting: 

1)

The (A) measurement is perpendicular from the gate in the CLOSED position.

2) There must be clearance for your gate opener to attach to the gate in the closed position.

This is most commonly  an  issue  on  columns.  Re-positioning  of  the  hinges  or  Push-To-Open

operation  may  be  re-quired to achieve clearance.

3) The brackets do not and must not move after installation.

4)

The "L" shape brackets can be mounted anywhere on the post or column.  They can be

mounted on a separate post or fence as  well.  The only factor of  importance is  that when

mounting of  the  brackets  is done the hole in the boomerang bracket that the gate opener

mounts on matches the setback on this page.

It is best to C-Clamp brackets on and test arm movement clearance before permanently attachin

them.

To  determine  the  position  of  the 

gate  mount-ing  bracket  (above  is 

for  the  post  mounting  bracket)  refer 

to 

step  9 

in 

the 

section 

"Installation  of operator - PTO" 

9

  

1/2

7

  

1/2

9

  

1/2

9

a, 

90

°

100

°

2.8 