2KW WIND TURBINE 

Operation Manual 

G

RADE    AAA 

**Please read carefully before using** 

 

 

 

EST energy saving technology 

                                                     

ESPECIALLY DESIGNED FOR EST LEBANON 

 

 

 

 

Summary of Contents for 2KW WIND TURBINE

Page 1: ...2KW WIND TURBINE Operation Manual GRADE AAA Please read carefully before using EST energy saving technology ESPECIALLY DESIGNED FOR EST LEBANON ...

Page 2: ...DC48v Generator style Three phase permanent magnet Charging method Constant voltage current saving Speed regulation method Yawing Electromagnetic brake Stop method Manual brake Tower height m 6 Weight kg not including batteries or inverter Main unit 95 Total 155 3 Preparation 3 1 Prepare batteries according to manufacturers specifications 3 2 Unpack and check the turbine parts and verify all parts...

Page 3: ...y 20cm Put the loop for guy wire through the loop welded to the tower section Close the loop with two wire clamps Repeat for each of the remaining cables 4 4 Put the heart ringer for steel wire across the o loop of turnbuckle and then rip the steel wire into the heart ringer Bend for a loop no less than 30cm long fasten with wire clamps Hook the turnbuckles of A B and D pits to the chain of anchor...

Page 4: ...e steel wires to make the mast in its vertical position Strain the steel wire until it can rebound lightly when gives a transverse force 4 14 Check the wire block screw buckle and all connecting point Make sure it is safe Then wrap and blocked them with galvanized wire Put anti corrosive grease on wire block screw buckle and all links where necessary 4 15 Connect the batteries in series to be a gr...

Page 5: ...ent damage 5 2 6 The power supply line of the wind generator should be run independently It can not be mixed used with other power supply lines DC power supply is safer and more efficient for lights For home electric appliances an AC power supply line from an inverter should be used It is suggested that the connector of a refrigerator should be inserted in a special plug with a timer to control it...

Page 6: ...e free and low maintenance If the installation and operation are correct failures will not appear under normal conditions In case of failure please consult following table Trouble Reason Solution Wind generator vibrating strongly 1 Steel cable guy line is loose 2 Hub blade bolts are loose 3 Blade is defective caused by outside force 4 Ices over on the surface of blades causes imbalance 1 Tighten t...

Page 7: ...e wires so as to reduce circuit electricity loss There is no output electric current in AC circuit of the Generator 1 There is a broken wire in the AC lines of the generator 2 There are circuit break in output line 3 Stator winding is burnt circuit is open Find out the reason and connect the wires 1 Find out the broken point then connect the wires 2 Disassemble then repair the damaged coil AC outp...

Page 8: ...Fig1 2KW WIND TURBINE SYSTEM AAA ...

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ...HY 2KW WIND TURBINE WIRING DIAGRAM ...