background image

WARNING

To reduce the risk of INJURY or DEATH, read and follow all 

instructions.

NEVER let children operate or play with barrier control. Controller MUST be installed at 
least 1.5m above the ground.
PEDESTRIANS SHOULD NOT CROSS THE PATH OF THE MOVING BARRIER.
Automatic boom barrier is designed for vehicles ONLY. Pedestrians MUST use sepa-
rate entrance.
Installation and maintenance MUST be executed by qualified service person. Keep 
boom barriers properly maintained.
Ground wire and current breaker MUST be connected.
Power MUST be cut off when performing installation or maintenance.
When power outage, power MUST be cut off before using the manual release under the 
motor to open the barrier.
ONLY operate when the boom barrier is in sight.
NEVER perform operating or setting without the boom installed. This WILL result in 
severe injury.
NEVER dismount the boom when barrier is at close status with spring attached. This 
WILL result in sever injury, even death.
DO NOT replace the original wire.

SAVE THESE INSTRUCTIONS.

1

AUTOMATIC BARRIERS ARE NOT FOR PEDESTRIAN!

!

Summary of Contents for BG-CM-300

Page 1: ...USER MANUAL Boom Barrier BG CM 300...

Page 2: ...p boom barriers properly maintained Ground wire and current breaker MUST be connected Power MUST be cut off when performing installation or maintenance When power outage power MUST be cut off before u...

Page 3: ...1 Direction Definition and Main Components of the Machine 2 A Close to Right B Close to Left Limit stopper Mounting Bracket C Main Components of the Motor Boom Holder Motor...

Page 4: ...ious ports for parking lot management system infrared sensor radar etc D Product contains multiple limit protection functions to keep a long life time 3 Specification Rated Power 24VDC Brushless 240W...

Page 5: ...e bottom of the Cabinet inside Mark out the boreholes for Expansion Bolts Fig 3 L and W according to the Fixed Bars Move away the cabinet Use an electric drill with 21mm to drill the boreholes The dep...

Page 6: ...ngs are set to be balanced in factory DO NOT change the boom length or weight if it is not necessary If the boom length or weight must be changed e g adding a Stop Sign on the boom the balance must be...

Page 7: ...tput Of Close 12V 500mA PT Infrared Sensor COM LOOP Detector COM STOP CLOSE OPEN Brown Wire Black Wire White Wire Blue Wire Red Light Red Light Control Signal Input Logic Signal Input Position Output...

Page 8: ...ly adjustboom to middle position 45 Power on Press and hold SET till display P1 Is the barrier Press OPEN and see the boom moving open Adjust F7 to change the motor s running direction NO YES Press an...

Page 9: ...ress Set Display 77 Display 77 or 81 Press Set 79 Function Parameter 81 Timer Parameter Press Stop End Press Open or Close to change corresponding value Press Open or Close to change value 6 3 Functio...

Page 10: ...D D D 8 28 D 4 D D 8 6 D48 D 8 4 2D48 D 2 D D 2 D 8 D 1D D 8 8 D 66 6 D 86D B2 D D B D 6 28 D D 82 D 6 D D 22DB 2 D B 2D B D28 D A3 D D A33D3050 D D 97 D CD 9A D 07A D 97 D 0 97D 9A D A3 D D 0 97D 07A...

Page 11: ...7 7 7 3 7 Transmitter Remote control setting...

Page 12: ...uantity Mark 1 2 4 5 6 7 8 9 Barrier Boom Double end bolt Cap nut Flat washer Spring washer Gasket Anchoring 1set 1pcs 2pcs 4pcs 4pcs 4pcs 2pcs 2pcs 10 11 12 Key Control unit Manual 2pcs Inciuding 2pc...

Page 13: ...24 Shambavi Building 23rd Main Marenahalli JP Nagar 2nd Phase Bengaluru 560078 Phone 91 8026090500 Email sales esslsecurity com www esslsecurity com...

Reviews: