Trouble shooting 

Problem Cause  Solution 

Motor cycles on and off 

Motor pulley set too large 
Excessive belt tension 
Blower shat frozen 

Adjust motor pulley 
Adjust belt tension 
Lubricate or replace bearings 

Water draining from overflow 

Float improperly adjusted 
Lime build up in float valve 

Adjust float 
Clean or replace float 

Blower shakes 

Belt or pulley loose 

Adjust or tighten 

Fails to start 

No electrical power 
Blown fuse or popped circuit breaker 

Check power 
Replace or reset 

Not cooling 

Water supply turned off 
Blocked water distributor 

Check water supply 
Clean distributor 

 
Maintenance 

Caution: turn off all electrical power to the cooler before opening or attempting service of any kind 

 

The motor is equipped with automatic thermal protection. If it shuts off for any reason, it can start back up without warning! 

 
Occasionally inspect your cooler for leaks, loose belt, blocked water lines, correct belt 
alignment or excessive residue build up on the pads. 
 

Belt tension 

At the proper tension, the belt will deflect ½” to ¾” when 3 to 5 pounds of pressure is 
applied to the belt approximately half way between the blower and motor pulleys. 
Adjust the belt tension using the motor bracket do not change the diameter of the pulley 
in order to adjust the belt tension.

 

 

Lubrication 

Lube the oil cups on the blower bearing.  Use SAE20 or SAE30 Non-Detergent oil.  Oil the 
blower motor only if oil holes exist. 
 

End of season

 

1. Drain and clean the reservoir.  Do not get water on the blower motor or pump motor. 
2. Remove the belt and hang it from the motor pulley. 
3. Remove the pads and clean carefully. 
4. Remove water distributor and hose out with garden hose.  Use a small nail to clean any 

deposits from the water holes. 

 

Pad Replacement 

Lime build up can occur in the water reservoir and on the pads.  Clean this off at least 
once per season.  If any rust or bare metal spots occur on the cabinet, the metal should be 
sanded, primed and painted with good quality paint. 

1/2" to 3/4"

Deflection

1. Remove wet section top. 
2. Remove water distributor assembly. 
3. Remove and discard old pads. 
4. Install new pad set.  Refer to diagram below or pad installation instructions 

for correct orientation.

 

 

5. Ensure that water distributor pad is centered over cooler pads. 
6. Carefully replace water distributor; ensure pads are not damaged while 

replacing assembly. 

7. Replace wet section top. 
 

Weight 

Model 

Dry Operating 

SI500-S 153 

224 

SI500-D 153 

224 

SI700-S 184 

255 

SI700-D 184 

255 

Wet Section Top

Tapa de la Seccion de Agua

Water Distributor

Distribuidora de Agua

Water Distributor Pad

Filtro que Distribuidora

de Agua

Red Stripe

Rojo Raya

Summary of Contents for SI-500S

Page 1: ...12 SI 700D12 SINGLE INLET Horizontal And Down Discharge Evaporative Air Cooler Read Save This Instruction Manual Our Mission We Will Respond to Our Customers With High Quality Products and Service Whi...

Page 2: ...This cooler is equipped with an automatic thermally protected motor If it shuts off on its own for any reason it can restart without warning If the motor shuts off because of thermal overload check i...

Page 3: ...the zero position 3 Turn the outside jaw of the pulley counterclockwise 3 full turns Align set screw with a flat on the threaded portion of the pulley and tighten This step will ensure that your cool...

Page 4: ...r end of tubing Insert the tubing into float valve and tighten Compression Nut to secure Reservoir Ferrule Faucet Note Tightening a compression fitting will cause that fitting to leak It is best to se...

Page 5: ...e diameter of the pulley in order to adjust the belt tension Lubrication Lube the oil cups on the blower bearing Use SAE20 or SAE30 Non Detergent oil Oil the blower motor only if oil holes exist End o...

Page 6: ...Replacement Parts 6...

Page 7: ...70116 70116 70116 22 Water distributor Distribuidor del agua 1 70043 70043 70043 70043 23 Pad media set Juego de filtros 1 70054 70054 70055 70055 24 Water shield set Juego de protectores del agua 1 7...

Page 8: ...parts as follows Cabinet components for one year from date of installation Evaporative media for five years from date of installation Exclusions from this warranty Essick Air Products is not responsib...