Trouble shooting
Problem Cause Solution
Motor cycles on and off
Motor pulley set too large
Excessive belt tension
Blower shat frozen
Adjust motor pulley
Adjust belt tension
Lubricate or replace bearings
Water draining from overflow
Float improperly adjusted
Lime build up in float valve
Adjust float
Clean or replace float
Blower shakes
Belt or pulley loose
Adjust or tighten
Fails to start
No electrical power
Blown fuse or popped circuit breaker
Check power
Replace or reset
Not cooling
Water supply turned off
Blocked water distributor
Check water supply
Clean distributor
Maintenance
Caution: turn off all electrical power to the cooler before opening or attempting service of any kind
The motor is equipped with automatic thermal protection. If it shuts off for any reason, it can start back up without warning!
Occasionally inspect your cooler for leaks, loose belt, blocked water lines, correct belt
alignment or excessive residue build up on the pads.
Belt tension
At the proper tension, the belt will deflect ½” to ¾” when 3 to 5 pounds of pressure is
applied to the belt approximately half way between the blower and motor pulleys.
Adjust the belt tension using the motor bracket do not change the diameter of the pulley
in order to adjust the belt tension.
Lubrication
Lube the oil cups on the blower bearing. Use SAE20 or SAE30 Non-Detergent oil. Oil the
blower motor only if oil holes exist.
End of season
1. Drain and clean the reservoir. Do not get water on the blower motor or pump motor.
2. Remove the belt and hang it from the motor pulley.
3. Remove the pads and clean carefully.
4. Remove water distributor and hose out with garden hose. Use a small nail to clean any
deposits from the water holes.
Pad Replacement
Lime build up can occur in the water reservoir and on the pads. Clean this off at least
once per season. If any rust or bare metal spots occur on the cabinet, the metal should be
sanded, primed and painted with good quality paint.
1/2" to 3/4"
Deflection
1. Remove wet section top.
2. Remove water distributor assembly.
3. Remove and discard old pads.
4. Install new pad set. Refer to diagram below or pad installation instructions
for correct orientation.
5. Ensure that water distributor pad is centered over cooler pads.
6. Carefully replace water distributor; ensure pads are not damaged while
replacing assembly.
7. Replace wet section top.
Weight
Model
Dry Operating
SI500-S 153
224
SI500-D 153
224
SI700-S 184
255
SI700-D 184
255
Wet Section Top
Tapa de la Seccion de Agua
Water Distributor
Distribuidora de Agua
Water Distributor Pad
Filtro que Distribuidora
de Agua
Red Stripe
Rojo Raya
5
Summary of Contents for SI-500S
Page 6: ...Replacement Parts 6...