background image

List of Materials

4

www.zephyronline.com

MODELS:

 AK8000AS AND AK8100AS

PARTS SUPPLIED

AK8000AS and AK8100AS

1 - Power Pack 
1 - Metal mesh fi lter (AK8000AS), 1 - Decorative mesh fi lter (AK8100AS) 
2 - Halogen light bulbs  (pre-installed) 
1 - Single internal blower (pre-installed) 
1 - Hardware package 

HARDWARE PACKAGE CONTENTS

PARTS NOT SUPPLIED

- Ducting, conduit and all installation tools
- Cable connector 

(if required by local codes)

- Optional stainless steel liner 

(AK08xxAS)

- Optional Recirculating Kit for AK8000AS (

ZRC-0100

)

Suction Cup (1)

Wire Caps (3)

M4 x 1”  (4)

M4 x 1-1/2” (4)

Summary of Contents for Tornado I AK8100AS

Page 1: ...re and Installation Guide www zephyronline com Model number Serial Number Date of Purchase Sales Dealer JAN08 0201 2008 Zephyr Corporation Twister AK8000AS Tornado I AK8100AS READ AND SAVE THESE INSTRUCTIONS ...

Page 2: ...www zephyronline com ...

Page 3: ...g Height Clearance 6 Ducting Options 7 Specifications 8 Electrical 9 Installing the Power Pack 10 FEATURES CONTROLS Slide Controls 11 MAINTENANCE Cleaning and Installing Filters 12 AK8000AS Recirculating Kit 13 Lights 14 TROUBLESHOOTING 15 LIST OF PARTS AND ACCESSORIES 16 Table of Contents ...

Page 4: ...ONS IN THE EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT b NEVER PICK UP A FLAMING PAN You may be burned c DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result d...

Page 5: ...installation is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances If codes permit and a separate ground wire is used it is recommended that a qualified electrician determine that the ground path is adequate Do not ground to a gas pipe Ch...

Page 6: ...er AK8100AS 2 Halogen light bulbs pre installed 1 Single internal blower pre installed 1 Hardware package HARDWARE PACKAGE CONTENTS PARTS NOT SUPPLIED Ducting conduit and all installation tools Cable connector if required by local codes Optional stainless steel liner AK08xxAS Optional Recirculating Kit for AK8000AS ZRC 0100 Suction Cup 1 Wire Caps 3 M4 x 1 4 M4 x 1 1 2 4 ...

Page 7: ... Ft 6 Round straight 1 Ft x Ft Subtotal column 1 Duct pieces T otal Equivalent number length x used 6 Round wall cap with damper 30 Ft x Ft Round wall cap with damper 30 Ft x Ft 7 10 Round 900 elbow 15 Ft x Ft 7 10 7 10 Round 450 elbow 9 Ft x Ft Ft Ft Ft 6 Round roof cap 30 Ft x Ft 7 10 Round roof cap 30 Ft x Ft Subtotal column 2 Subtotal column 1 Total ductwork 6 roundto 3 1 4 x 10 rect transitio...

Page 8: ...ize If turns or transitions are required install as far away from hood duct output and as far apart between the two as possible Minimum mount height between range top to hood bottom should be no less than 26 Maximum mount height should be no higher than 36 It is important to install the hood at the proper mounting height Hoods mounted too low could result in heat damage and fire hazard while hoods...

Page 9: ...ll exhaust must be ducted to the outside Use metal ductwork only Fasten all connections with sheet metal screws and tape all joints with certified Silver Tape or Duct Tape Some Ducting Options Installation Ducting Options side wall cap w gravity damper side wall cap w gravity damper Soffit or crawl space Roof Pitch w Flashing Cap ...

Page 10: ...ne com Installation Specifi cations top front bottom side 4 1 8 5 3 8 3 3 4 10 5 8 5 7 8 1 1 16 10 1 2 11 13 16 26 9 16 27 9 16 27 9 16 25 3 4 9 3 8 8 11 16 11 3 16 11 3 16 10 5 16 1 5 16 15 18 15 16 10 5 16 1 1 8 C L ...

Page 11: ...ling local codes and ordinances Electrical Supply This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere circuit breaker or time delay fuse Wiring must be 2 wire w ground Please also refer Electrical Diagram labeled on product Cable Lock A cable locking connector not supplied might also be required by loc...

Page 12: ... the wood base note Wood blocking may need to be added to cabinet base if additional support is needed see FIG 3 and FIG 4 5 Install duct work and seal with duct tape 7 Install electrical 8 Remove all packing materials before using Power Pack Switch power on and check for leaks around duct tape 9 Install filter CAUTION At least two installers are required due to the weight and size of the hood Duc...

Page 13: ...ed Selection 1 Lights Bright Dim Off 2 0 I I I Features Controls Slide Controls BLOWER ON OFF SPEED SELECTION 0 is off I is low speed II is medium speed and III is high speed LIGHTS BRIGHT DIM OFF 0 is off I is dim and II is bright 1 2 ...

Page 14: ... The filters are intended to trap residue and grease from cooking Although the filters should never need replacing they are required to be cleaned every 30 days or more often depending on cooking habits Filters may be placed in dishwasher at low heat or soaked in hot soapy water Dry filters and re install before using hood Installing Metal Mesh Filter FIG 5 1 Place back of filter into channel on l...

Page 15: ...a charcoal filter is required to be installed on top of the standard metal mesh filter and a return air vent is needed to direct air back into the kitchen The standard metal mesh filter is intended to capture residue from cooking and the optional charcoal filter helps to purify fumes exhausted from cooking in recirculating mode Purchase recirculating kit as follows for AK8000AS ONLY Hood Model Par...

Page 16: ...rning bulb counter clockwise Note Bulb does not unscrew it turns 60 degrees stops and falls out If bulbs are difficult to turn due to prolonged use firmly attach a glass suction cup approximately the diameter of the bulb or use a rubber latex glove and turn counter clockwise Replacement bulbs are available at specialty lighting stores Purchase type MR16 GU 10 35W halogen For Zephyr part numbers pl...

Page 17: ... thermally protected system cool down 3 Damaged capacitor 3 Change the capacitor The unit is vibrating 1 The blower is not secure in place 1 Tighten the blower in place 2 Damaged blower wheel 2 Change the blower 3 The hood is not secured in place 3 Check the installation of the hood The motor is working but the lights are not 1 Defective halogen bulb 1 Change the halogen bulb 2 The light bulb is l...

Page 18: ... 0023 Metal Mesh Filter each 50200022 Decorative Mesh Filter each 50200024 Optional Accessories Liner 30 AK0800AS Liner 36 AK0836AS Recirculating Kit AK8000AS ONLY ZRC 0100 To order parts visit us online at http store zephyronline com or call us at 1 888 880 8368 List of Parts and Accessories ...

Reviews: