Installation
Use a Competent Person or Qualified Electrician
• This oven must be installed in compliance with local safety standards.
• Wiring connections must be in accordance with Local Wiring Rules and any particular conditions of the
local authority.
• Refer to data plate for rating information. The data plate is positioned behind the bottom of the oven door.
The electrical wiring diagram is positioned on the rear panel of the appliance.
• A means of disconnection with a contact separation of at least 3 mm must be supplied in the fixed wiring.
• This appliance must be properly earthed.
• Do not lift the appliance by the door handles.
• Prepare the cupboard opening to match your appliance measurements. (See diagrams)
• Slide appliance into the cupboard, ensuring that the supply cable does not kink.
• To prevent tipping, secure your oven into the cupboard by fastening with the 2 screws supplied.
• The cabinet must be suitable for use in built in ovens and capable of withstanding 75°C Installation into low
temperature tolerant cabinetry (e.g. Vinyl coated) may result in deterioration of the low temperature coating
by discolouring or bubbling.
• We cannot accept responsibility for damage caused by installation into low temperature tolerant cabinets.
• After installation, test and ensure that the appliance operates correctly.
• The electrical connection of this oven should be carried out by a competent person, if in doubt consult
a qualified electrician, according to the instructions in this installation section and in compliance with
the current regulations.
• The oven is intended for indoor domestic use only.
• The manufacturer reserves the right to introduce changes which do not affect the operation of
the appliance.
To avoid any potential hazard, you must follow our instructions when you install your appliance.
Failure to install the appliance correctly could invalidate any warranty or liability claims.