background image

Page 5 of 55   

  WARNING 

AVERTISSEMENT 

Do not use this appliance if any part has 
been under water. Immediately call a 
qualified service technician to inspect the 
appliance and to replace any part of the 
control system and any gas control which 
has been under water. 

Ne pas utiliser cet appareil s’il a été plongé, 
meme partiellement, dans l’eau. Appeler un 
technician qualifié pour inspecter l’appareil et 
remplacer toute partie du système de 
commande et toute commande qui a été 
plongée dans l’eau. 

Toddlers, young children and others may be 
susceptible to accidental contact burns. A 
physical barrier is recommended if there are 
at risk individuals in the house. To restrict 
access to a fireplace or stove install an 
adjustable safety gate to keep toddlers, 
young children and at risk individuals out of 
the room and away from hot surfaces. 
Any safety screen or guard removed for 
servicing an appliance must be replaced 
prior to operating the appliance. 
Installation and repair should be done by a 
qualified service person.  The appliance 
should be inspected before use and at least 
annually by a professional service person.  
More frequent cleaning may be required due 
to excessive lint from carpeting, bedding 
material, et cetera.  It is imperative that 
control compartments, burners and 
circulating air passageways of the appliance 
be kept clean. 

Les tout-petits, les jeunes enfants et d'autres 
peuvent être sensibles aux brûlures par 
contact accidentel. Une barrière physique est 
recommandé s'il ya des personnes à risque 
dans la maison. Pour restreindre l'accès à une 
cheminée ou un poêle installer une barrière de 
sécurité réglable pour garder les tout-petits, 
les jeunes enfants et les personnes à risque de 
la salle et à l'écart des surfaces chaudes. 
Tout écran ou grille de protection pour 
l'entretien d'un appareil doit être remplacé 
avant de faire fonctionner l'appareil. 
Installation et réparation doit être effectuée par 
un technicien qualifié. L'appareil doit être 
inspecté avant son utilisation et au moins 
annuellement par un technicien qualifié. Un 
nettoyage plus fréquent peut être nécessaire 
en raison de peluches provenant des tapis, 
literie, etc. Il est impératif que les 
compartiments de contrôle, les brûleurs et les 
conduits d'air de l'appareil soient gardés 
propres.

 

This fireplace is a vented product. This 
fireplace must be properly installed by a 
qualified service person. The glass door 
must be properly seated and sealed. If this 
unit is not properly installed by a qualified 
service person with the glass door properly 
seated and sealed gas leakage can occur. 

Ce foyer est un produit ventilé. Ce foyer doit 
être correctement installé par un technicien 
qualifié. La porte en verre doivent être placés 
correctement et scellé. Si cet appareil n'est 
pas correctement installé par un technicien 
qualifié avec la porte en verre bien en place et 
des fuites de gaz scellés peuvent se produire. 

Caution: Label all wires prior to 
disconnection when servicing controls. 
Wiring errors can cause improper and 
dangerous operation. 

Attention 

: Au moment de l’entretien des 

commandes, étiquetez tous les fils avant de 
les débrancher. Des erreurs de câblage 
peuvent entraîner un fonctionnement 
inadéquate et dangereux. 

Verify proper operation after servicing 

S’assurer que l’appareil fonctionne 
ad

équatement une fois l’entretien terminé 

If appliance is installed directly on carpeting, 
vinyl tile or other combustible material other 
than wood flooring, the appliance shall be 
installed on a metal or wood panel extending 
the full width and depth of the fireplace. 

Si l'appareil est installé directement sur un 
tapis, carreaux de vinyle ou autre matériau 
combustible autre qu'un plancher de bois, 
l'appareil doit être installé sur un panneau de 
métal ou de bois se prolongeant sur toute la 
largeur et la profondeur de la cheminée. 

Summary of Contents for ESS45

Page 1: ...om a neighbour s phone Follow gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service age...

Page 2: ...ez rejoindre le fournisseur de gaz appelez le service des incendies L installation et l entretien doivent tre assur s par un installateur ou un service d entretien qualifi ou par le fournisseur de gaz...

Page 3: ...Line Installation 19 3 3 3 Direct Vent Information 20 31 3 3 4 Glass Media Installation 32 3 3 5 Door Installation and Safety Screen 33 34 3 3 6 Initial Firing 35 3 3 7 Pilot Flame Adjustment 35 3 3 8...

Page 4: ...s et intoxication au monoxyde de carbone DUE TO HIGH TEMPERATURES THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZA...

Page 5: ...reil doit tre remplac avant de faire fonctionner l appareil Installation et r paration doit tre effectu e par un technicien qualifi L appareil doit tre inspect avant son utilisation et au moins annuel...

Page 6: ...ORIFICE SIZE 0 4500 FORMAT D ORIFICE 2 X 49 DMS 2 X 58 DMS AIR SHUTTER VOLET DE L AIR OPEN 1 8 min 3 175mm FULLY OPEN CONTROL VALVE TYPE TYPE DE SOUPAPE Skytech AF 40004 Skytech AF 40004 VENTING VACUA...

Page 7: ...void the warranty This appliance has been certified for use with natural gas and propane This appliance is not for use with solid fuels CODES D INSTALLATION Cet appareil est un appareil vent direct qu...

Page 8: ...s will activate the setup mode Setup mode can also be activated by pressing the FLAME REAR and PROG TIME buttons simultaneously for 5 seconds The control will exit setup mode if no button is pressed f...

Page 9: ...trol to operate the unit for up to 3 hours in 10 minute increments It can be operated in either the Manual or Thermostat Modes To enter Timer Mode press and release the TIMER button The Timer icon wil...

Page 10: ...the control out of Child Lock out mode repeat the above step CP will disapper from the screen Learn Function To program the system to a transmitter press the LEARN button on the Main Module A single...

Page 11: ...a must be kept clear and free from combustible materials gasoline and other flammable liquids and vapors La zone appareil doit rester clair et exempt de mat riaux combustibles essence et autres vapeur...

Page 12: ...toddlers young children and at risk individuals out of the room and away from hot surfaces Any safety screen or guard removed for servicing an appliance must be replaced prior to operating the applia...

Page 13: ...tempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace an...

Page 14: ...provoquer une explosion ou un incendie D N utilisez pas cet appareil s il a t plunge dans l eau meme partiellement Faites inspecter l appareil par un technician qualifi et remplacez toute partie du sy...

Page 15: ...s components as this will damage the valve Ne pas communiquer 120 VAC la valve de contr le du gaz ou de ses composantes car cela endommagerait la vanne 3 2 UNPACKING Please check the appliance careful...

Page 16: ...ANCES TO COMBUSTIBLES A 58 TO INTERNAL CEILING B 2 TO INTERNAL BACK COMBUSTIBLES C 16 5 TO BACK WALL FROM FRONT OF UNIT D 6 FROM EDGE OF FIREPLACE TO SIDE WALL E 38 75 FROM BOTTOM OF FIREPLACE TO STUD...

Page 17: ...exigences du fournisseur de gaz Le tableau placement manteau sur cette page illustre les dimensions et les emplacements admissibles chemin e L angle de 45 degr s peut tre utilis pour d terminer la tai...

Page 18: ...E MATERIAL MATIERE NON COMBUSTIBLES Non combustible material will be supplied by the manufacturer This must be installed on top of the fireplace as shown above to meet installation codes Mat riaux non...

Page 19: ...ing system at test pressures equal to or less than 1 2 psi 3 45 kPa Cet appareil doit tre isol de l alimentation en gaz en fermant son robinet arr t pendant tout test de pression de la canalisation de...

Page 20: ...ur partie 1604247B CPI vacuation avec adaptateur partie TM 4AA2 ou Metal Fab vacuation directe l utilisation de Metal Fab adaptateur partie 4DDA Installez les composants de ventilation selon les instr...

Page 21: ...maximum vertical system consists of Dura Vent adapter Part 0924N3 directly on top of unit or Selkirk adapter Part 1604247B Up to 34 10363 mm of vertical length Fire stop Flashing Collar Dura Vent Ter...

Page 22: ...mination cap part SV4CGV Use a ceiling fire stop when penetrating a ceiling or floor Use a wall thimble when penetrating an inside or outside wall Vent terminals shall not be recessed into a wall or s...

Page 23: ...zontal termination cap part IMC1070A or IMC1070B Note 2 Ply Horizontal venting shall be supported by means of a steel strap every 3 The maximum vertical system consists of Up to 34 10363mm of vertical...

Page 24: ...ll values are in feet EXAMPLES MINUMUM VERTICAL V1 MAXIMUM HORIZONTAL H1 H2 H3 H4 4 10 8 20 NOTE All vent dimensions are measured from the appliance surface where the vent connects to the point where...

Page 25: ...Page 25 of 55 34 20 A A B B Example Where A A Vertical 2 And B B Horizontal 5 15 MINIMUM 15 MAXIMUM...

Page 26: ...o follow above instructions for resealing venting when reconnecting to system FIGURE 7 VENT RESTRICTOR INSTALLATION VENT RESTRICTOR To fasten the Restrictor Plate to the ceiling of the firebox 1 Remov...

Page 27: ...pipe Mark the center line of the pipe facing the wall allowing for a 1 4 rise per foot of horizontal example 10 ft of horizontal would require a rise of 2 5 NOTE ALLOWING THE VENT PIPE TO SLOPE DOWN T...

Page 28: ...head sheet metal screws then attach the 7 vent to the termination and fasten with 4 8 x hex head sheet metal screws be sure that the flex vent overlaps the termination collars a minimum of 2 Then atta...

Page 29: ...rame as shown in the diagram below NOTE ALWAYS CHECK YOUR LOCAL CODES BEFORE INSTALLING VENTING CLEARANCES ETC MAY VARY FROM STATE TO STATE PROVINCE TO PROVINCE TOUJOURS v rifier les codes locaux avan...

Page 30: ...2 from any wall To prevent water seepage install the flashing with upper portion under the roofing material and the lower portion over the roofing material Note Do not fasten down until the final adju...

Page 31: ...M Clearance under veranda 12 in 30 cm porch deck or balcony 0 0 3 3 1 In accordance with the current CSA B149 1 Natural Gas and Propane Installation Code 2 In accordance with the current ANSI Z223 1 N...

Page 32: ...d in any low or high areas adjust the amount of river glass to correct gas flow Transformez votre chemin e et attendez environ 10 15 minutes jusqu ce que les flammes sont une belle couleur jaune Notez...

Page 33: ...oval is in reverse order L enl vement est dans l ordre inverse If the glass has been damaged or broken it is highly recommended that you contact a qualified service person Remove the broken pieces be...

Page 34: ...er avec les dentelures de profondeur sur le support Voir l image ci dessous PINS Picture shown is looking at the left side of the fireplace and illustrating the screen bracket depth serrations mounted...

Page 35: ...ge froid la vapeur peut se condenser et voiler le verre et les flammes peuvent tre partiellement bleu Apr s quelques minutes l humidit dispara t et les flammes deviendront jaunes Contr ler visuellemen...

Page 36: ...e Toutes les vannes ont t pr programm es et certifi pour l installation une altitude de 0 4500 pieds 0 1372m d altitude Lors de l installation de cet appareil haute altitude il est n cessaire de baiss...

Page 37: ...es aimants pour la facilit d installation et peut tre retir de la paroi arri re 5 Once removed from the wall the fan will slide out through the opening Une fois retir du mur que les fan vont glisser p...

Page 38: ...OMMENCER TOUT TRAVAIL SUR LA FOYER CELA DEVRAIT ETRE FAIT PAR UNE LICENCE VOTRE FOURNISSEUR DE GAZ 1 Remove the front access panel from below the door Remove the door as in 3 3 5 Retirez le panneau d...

Page 39: ...ux combustibles essence et autres vapeurs et liquides inflammables 4 2 RECOMMENDED SERVICE SERVICE RECOMMAND 1 The venting system should be annually inspected by a qualified agency Le syst me de venti...

Page 40: ...is plugged disassembly may be required to remove any foreign material from the orifice or tubing When the appliance is back in service check the pilot flame pattern For re lighting refer to the lighti...

Page 41: ...6 Undo the pilot gas line at the gas valve Annuler la conduite de gaz pilote la vanne de gaz 7 Disconnect the thermostat or on off switch wires from the valve if applicable D branchez le thermostat ou...

Page 42: ...l not stay lit after following the lighting instructions A Thermocouple Valve 1 Weak or improperly located pilot flame 1 Adjust and clean pilot The flame must impinge on or engulf the thermocouple as...

Page 43: ...acement V Flame burns blue and lifts off burner 1 Insufficient combustion air being supplied 1 Ensure that no foreign material blocks air inlets Ensure the vent is adequate 2 Manifold pressure set too...

Page 44: ...5 45 N A Orifice LP MP0505 56 N A Propane Conversion Kit LPCKESS45 CSA C US Natural Gas Conversion Kit NGCKESS45 CSA C US Intermittent Pilot Remote Control Valve Parts Description Part Pilot Assembly...

Page 45: ...ansferable and may not be extended whatsoever by any of our representatives A licensed authorized service technician or contractor must have installed the gas fireplace Installation must be done in ac...

Page 46: ...ROTECTION Produits Inca Metal Cutting sont con us avec des composants et des mat riaux de qualit sup rieure assembl s par des artisans qualifi s qui sont fiers de leur travail Le br leur et la valve s...

Page 47: ...re ann e Inca de coupe en m tal peut sa discr tion se d charger de toutes obligations l gard de cette garantie en remboursant l acheteur d origine le prix de gros de toute pi ce garantie qui est d fec...

Page 48: ...Page 48 of 55 8 0 LABEL INFORMATION...

Page 49: ...remove the grounding prong from this plug AVERTISSEMENT Instructions la terre lectrique Cet appareil est quip d un trois broches terre pour votre protection contre les risques de choc lectrique et do...

Page 50: ...Page 50 of 55 APPENDIX A AMERICAN FLAME VALVE INFORMATION...

Page 51: ...Page 51 of 55 APPENDIX A Continued...

Page 52: ...is in the ON position and the appliance ON OFF switch is turned on the pilot will spark and light When the appliance ON OFF switch is turned to OFF the pilot will stay ON when the main burner shuts o...

Page 53: ...or propane Each unit leaves the factory equipped for one specific fuel but it is simple to field convert the unit to an alternate fuel The original type of fuel is marked on the ratings label of the...

Page 54: ...trical power before proceeding with the conversion ATTENTION l alimentation en gaz doit tre coup e avant de d brancher l alimentation lectrique avant de proc der la conversion 2 Remove the door rock g...

Page 55: ...ty that the conversion has been completed properly as per instructions in this manual Cet appareil a t converti sur DATE _______________________________________ partir de NG LP pour LP NG PAR_________...

Reviews: