100 MF SE 

MULTI-FUEL AND SMOKE EXEMPT STOVES 

 

                

 

 

 

 

 

INSTALLATION & USER INSTRUCTIONS 

(TO BE LEFT WITH THE CUSTOMER)

 

 

UK & Ireland 

 
 
 
 

 

 

 

 

GB  IE

 

Summary of Contents for 100 MF SE

Page 1: ...100 MF SE MULTI FUEL AND SMOKE EXEMPT STOVES INSTALLATION USER INSTRUCTIONS TO BE LEFT WITH THE CUSTOMER UK Ireland GB IE...

Page 2: ...ert advice if necessary Do not fit an extractor fan in the same room as the appliance An adequate air supply for combustion and ventilation is required As this stove does not exceed 5 0 kW nominal hea...

Page 3: ...ing fitted Be a minimum 4 6m high from hearth level to pot Be terminated at least 600mm above roof level so that the chimney does not terminate in a pressure zone see Fig 2 Be free from cracks severe...

Page 4: ...4 Fig 1 Ideal Flue Connections Fig 2 Chimney and Flue Performance...

Page 5: ...y air intake closed and the airwash control fully open Maximum The primary air intake can now be opened to allow the stove to burn at maximum rate Give the stove some time for the burning rate to beco...

Page 6: ...MENSIONS CLEARANCES Fig 3 Stove Dimensions Log Stores The height of the fitted legs on a 100 are 150mm The log stores available are 220mm and 300mm in height Adding an additional 70mm or 150mm in heig...

Page 7: ...d not exceed 80 C There should be sufficient space around the stove for service work Hearth The construction of the hearth must conform to Building Regulations must be firm non combustible and capable...

Page 8: ...for top flue connection For a rear flue connection an optional ESSE rear flue box or an ESSE cast iron flue collar are available The rear flue box attachment allows the stove to be installed further...

Page 9: ...dditional loose parts supplied inside your stove include A stove mitt for removing the ash pan adjusting the primary air controls adjusting the air wash control and operating the door handle Fig 5 sho...

Page 10: ...ternal surfaces will be hot to touch when in operation and due care will need to be taken Fig 6 Stove Controls Fig 7 Riddling Grate Open Fig 8 Riddling Grate Closed Always use stove mitts when adjusti...

Page 11: ...ng the primary air control for a short period will revive it When reviving a low fire it is important to also use kindling before adding larger logs to help prevent smoke Wood burns efficiently when t...

Page 12: ...eady When loading wood make sure that the end grain of the wood in the stove is pointing away from the glass otherwise the moisture and gases coming from the end grain of the wood will dirty the glass...

Page 13: ...up to the back of the stove to the level of the top of the back brick Open the primary air inlet and let the fire burn for a period on high rate in order to hit the stove back up to temperature and d...

Page 14: ...e for instance Remove all the ashes from the grate and ash pan and use a vacuum cleaner nozzle to clean ash from the base of the stove Remove the baffle plate and brush the flue ways Close the door an...

Page 15: ...r stove you should first contact your ESSE dealer who will bring your concerns to our attention We will assess the nature of the complaint and either send replacements parts for your dealer to fit or...

Page 16: ...E Engineering Limited Ouzledale Foundry Long Ing Barnoldswick Lancashire BB18 6BJ Tel 01282 813 235 Fax 01282 816 876 e mail enquiries esse com Website http www esse com On line store http www esse co...