HARDWARE DESCRIPTION 

Page 3 

 

Terminal blocks 

BATT 

12Vdc power supply input

  

AR 

Received alarm indicator light

  

AI 

Given alarm indicator light

 

 

+12 

Output 12Vdc (max. 100mA)

 

AL1 

Alarm input 1 

AL2 

Alarm input 2

 

COM 

Common terminal for inputs IN1, Reset 

IN1 

Alarm filter input

 

Reset 

Reset input

 

VV2+ 

Output Handsfree 2

 

VV2- 

Common Handsfree 2

 

VV1+ 

Output Handsfree 1 

VV1- 

Common Handsfree 1

 

TEL 

Local Telephone 

Optional PSTN-line board 

LTI 

PSTN-line or universal GSM gateway input 

 

Ground terminal 

Optional relay board 

RL1 

Relay contact 1 

 

RL2 

Relay contact 2 

Remark:  for the correct operation of IN1 and Reset inputs a diode 

is required between ter12 and COM (inserted by 
factory). 

Summary of Contents for ST56 GMV

Page 1: ...19 02 2014 Alarm system for elevators ST56 GMV QUICK GUIDE...

Page 2: ...ration red and GSM200 signal strength green C Connectors for AL100 power supply D Connectors for optional relay board E Serial plug for connection to elevator CPU F Reset pushbutton G RJ11 connector f...

Page 3: ...1 Reset IN1 Alarm filter input Reset Reset input VV2 Output Handsfree 2 VV2 Common Handsfree 2 VV1 Output Handsfree 1 VV1 Common Handsfree 1 TEL Local Telephone Optional PSTN line board LTI PSTN line...

Page 4: ...and AL2 The jumper JP8 A in picture 1 defines the behaviour of the inputs AL1 and AL2 The inputs AL1 and AL2 are at 12V the alarm occurs when they are closed to a terminal ex VV2 The inputs AL1 and AL...

Page 5: ...0 module by means of the supplied cable PSTN line or universal GSM gateway Remove the jumpers set in the dedicated connector for the PSTN line board s picture 2 Insert the optional board in the dedica...

Page 6: ...mation concerning the elevator location dial and pronounce the message To listen again to the previous message dial Make an external call to check the telephone line presence dial and digit the teleph...

Page 7: ...PROGRAMMING ACCESS TO PROGRAMMING INSTALLER or OPERATOR PASSWORD by default EXITING THE PROGRAMMING INSTALLER or OPERATOR PASSWORD by default TYPE OF TELEPHONE LINE INST PSTN line or universal GSM gat...

Page 8: ...sy message 22 sec LISTEN TO MESSAGES INST OPER identification message listen courtesy message DEAD BATTERY ALARM INST disabled alarm enabled alarm ADEMCO PROTOCOL ID INST 4 digits ID ESSE TI P100 PROT...

Page 9: ...actory default 2 FILTER ACTIVATION INST OPER disabled enabled FILTER INPUT NC NO INST OPER normally closed normally open ACKNOWLEDGE INST from 1 to 3 digits factory default 5 HANDSFREE ACTIVATION INST...

Page 10: ...ROGRAMMING CONNECTION TIME AFTER AUTOMATIC ANSWER INST minutes from 1 to 9 factory default 3 CHANGING THE INSTALLER PASSWORD INST old new new LISTENING TO PROGRAMMING prefix programming code RESTORING...

Page 11: ...nal board RELAY 1 RELAY 2 Remote use with ST56 in stand by Call ST56 and wait for the answer After a short series of DTMF tones followed by the elevator identification message dial INSTALLER OR OPERAT...