CONNECTING THE EMERGENCY CALL BUTTONS
Page 7
Other pushbuttons
The pushbuttons of pit and bottom of elevator car can only be connected to an
AL1 terminal block if they are of the same type as the car pushbutton (voltage
free or powered, normally open or normally closed).
The pushbuttons of pit and bottom of elevator car can only be connected to
AL2 terminal block if they are voltage-free.
Note:
the reset input (AL2) must be configured as alarm input with
the “Inputs setting” programming (codes 390 or 55).