Page 22
PROGRAMMING
ADVANCED PROGRAMMING
EMERGENCY CALL
BUTTONS DELAY
(INST)
(seconds, from 2
to
9; factory default
3
)
INPUTS
NORMALLY
OPEN/CLOSED
(INST)
input
(1=AL1
2=AL2
3=IN1)
type
(0=normally closed
1=normally open
)
NO EXTERNAL
POWER SUPPLY
ALARM *
(INST)
* 5HL-600 only
disabled alarm
enabled alarm with XX minutes delay
(from 01 to 99)
BUILT-IN
SPEAKER UNIT
DIAGNOSTIC
ALARM
(INST)
disabled alarm
enabled alarm
FILTER
ACTIVATION
(INST/OPER)
disabled
enabled
FILTER BYPASS
(INST)
(seconds, from 15 to
30
)
ALARM
OPERATION
WITHOUT
TELEPHONE LINE
(INST)
AI indicator light lit and courtesy message
AI indicator light unlit and no courtesy message
AI indicator light lit and no courtesy message
REPEATS OF
COURTESY
MESSAGE
DURING
AN ALARM
(INST)
(seconds between two courtesy messages, from
02 to 59; 00=no courtesy message;
01=one
courtesy message for each call
)
“COMMUNICA-
TION
ACTIVATED”
MESSAGE
SETTING
(INST)
disabled message
enabled message