20
21
To synchronize hands on Big Date
Chronograph:
After changing the battery, or in the event of
an error, the chronograph hands can be
realigned to zero if needed. A single push
(quick press and release) of button
A
will
advance the selected hand by one increment.
To advance hand rapidly, depress and hold
push button
A
for longer than one second.
1. Pull crown out to position 3.
2. Press and hold buttons
A
and
B
simulta-
neously for at least 2 seconds to enter cor-
rective mode: Center-mounted chronograph
hand
C
will rotate 360º, indicating mode has
been activated.
3. Adjust chronograph seconds hand
C
using
button
A
.
4. Press button
B
.
5. Adjust tenths-of-a-second counter
G
using
button
A
.
NOTE: On ESQ by Movado Big Date
Chronograph models, tenths-of-a-second
counter
G
will run continuously for the first
30 seconds after the chronograph feature is
engaged, then return to 0 and remain on 0
until chronograph is stopped. When chrono-
graph is stopped, hand
G
will advance to
indicate elapsed tenths-of-a-second like any
standard quartz chronograph. If the chrono-
graph runs for more than 30 minutes, then
tenths-of-a-second hand
G
will become an
hour-recorder, measuring 10 hours per one
complete rotation.
To operate Big Date Chronograph:
For Chronograph function overview, Simple
chronograph functions, Accumulated time
functions, Split-time or intermediate time
functions, and First-place and runner-up
results, please see instructions for Analog
Chronographs 1/10 Second.