3. Basic AT Commands
3.2.14. AT+RFAUTOTRACE—Sets RF Frequency Offset Trace
3.2.15. AT+SYSRAM—Checks the Remaining Space of RAM
3.2.16. AT+SYSADC—Checks the Value of ADC
Command
Query Command:
AT+RFAUTOTRACE?
Set Command:
AT+RFAUTOTRACE=<enable>
Response
+RFAUTOTRACE:<enable>
OK
OK
Parameter
<enable>
:
‣
0: disables RF frequency offset trace
‣
1: enables RF frequency offset trace
Notes
•
The RF frequency offset trace function is enabled by default.
•
This configuration will be saved in the user parameter area in flash, and take effect after the chip
restarts.
Example
AT+RFAUTOTRACE=0
AT+RST
Query Command
AT+SYSRAM?
Response
+SYSRAM:<remaining RAM size>
OK
Parameter
<remaining RAM size>
: remaining space of RAM, unit: byte.
Query Command
AT+SYSADC?
Response
+SYSADC:<ADC>
OK
Parameter
<ADC>
: the value of ADC; unit: 1/1024V.
Espressif
!
/58
15
2017.05