May 19
th
, 2021
Supra-5000 Digital Cinema and Secured Media Projection System
Installation Manual
- 30 -
Power Requirements
▪
The Supra-5000 projector will be installed with either one of two types of power supplies
depending on the region the projector has been shipped to. Please check the labeling on the
Supra-5000 packing (refer to
) to know which type of power supply has been installed
in the projector. The two types of power supplies are listed below:
Type
Rating
Label
Type 1
200-240Vac, 50/60Hz, 4-3A
[single phase]
200-240Vac (2W+ ), 50/60Hz, 4-3A
[dual live line]
Type 2
100-240Vac, 50/60Hz, 9-4A
[single phase]
Table 7
Please ensure that the voltage and current rating of the power outlet to which the projector is
connected is matched to the power supply installed in the Supra-5000.
▪
The total power consumption is 750W. The power supply system should be stable and the
voltage fluctuation range should be less than 10%. The power consumption of the projection
room should meet the rated power consumption requirements of the projector and UPS with
voltage stabilizing function should be configured, if necessary.
▪
Balance and distribution of AC power phase:
Try to avoid installing the projector's phase
line, high-power electrical equipment and frequency conversion equipment (such as air
conditioners, audio amplifiers, etc.) on the same phase line to avoid power interference.
Pay attention to the distribution of each phase to make the phase electrical load as
balanced as possible.
▪
When the equipment in the projection room is not turned ON; the measured zero-ground
voltage should be less than 1V.
▪
Wiring
: Use multiple strands of flexible wires as the power line. For strong power, the wire
should be routed independently. Do not mix it with weak wires in the same trunking.
▪
lists the various types of power plugs that can be provided along with the projector
,
for different regions.