Procedure for factory repairing and returning 

 

A.

 

Prepare  a  Return  Material  Authorization  Form  (available  from  ESPAN  or  its  local 
representative) with the following information: 

 

Model and Serial Number of the equipment. 

 

Specify Failure Symptom 

 

Operating Environment (indoor, outdoor, temperature, vibration, etc.) 

 

Approximate date of installation or number of operating hours. 

 

Name and telephone number of contact person if questions arise. 

 

 

B.

 

Enclose  the  information  with  the  equipment  and  pack  in  a  commercially  accepted 
shipping container with sufficient packing material to ensure that no shipping damage 
will occur. 

Ship to the appropriate location as below 

 
Attention:  
Service Department  
ESP Technologies Company Limited 
76/82 Changwattana Rd., Anusawari,  
Bangkhen, Bangkok 10220, Thailand 

Telephone: +66(0)25226245~7 
Fax: +66(0)25226248 
 

C.

 

Your equipments will be tested, repaired and inspected at the factory and return within 
ten days (exclude shipping back period). 

 

D.

 

In case of urgent service needs or repairing status enquiry, please contact the 
appropriate Service Department or your local ESPAN representative. 

 

WARRANTY:  

 

ESP  Technologies  Ltd.  warrants  equipment  of  its  own  manufacture  to  be  free 
from  defects  in  material  and  workmanship,  under  normal  conditions  of  use  and 
service.  

 

ESP  Technologies  Ltd.  will  replace  any  components  found  to  be  defective,  upon 
its  return,  transportation  charges  prepaid,  within  one  year  of  its  original 
purchase.  

 

ESP  Technologies  Ltd.  will  extend  the  same  warranty  protection  on  accessories, 
which  is  extended  or  implied,  beyond  its  obligation  to  replace  any  components 
involved. Such warranty is in lieu of all other warranties expressed or implied. 

Summary of Contents for ESPAN-04 Series

Page 1: ...Alarm Monitoring ESPAN 04 Series Annunciator System Compact Programmable Type User Manual ESP TECHNOLOGIES LIMITED www esptechno com ESPAN...

Page 2: ...l Description 1 Features 2 Specifications 3 Dimension and Cut Out 4 Operating Principle 5 Alarm Sequence 5 How to connect the system 7 Circuit Wiring Diagram 8 How to Configured the ESPAN 04 9 Configu...

Page 3: ...lly accompanied by an alarm or supervisory system of certain parameters called fault Definition of fault is expressed by the opening or closing of a contact This information represents any modificatio...

Page 4: ...ness LED display 3 mm in 3 colors R G A can be selected by Software Integrated two test functions Lamp Test Function Test in one push button TEST Time of auto acknowledge function can be set from 1 24...

Page 5: ...rs Red Green Amber Power Source Input voltage 24Vdc 48Vdc 95 265 VAC DC Power consumption max 10 Watt Environment Operating Temp 10 to 55 C Storage Temp 10 to 70 C Humidity up to 95 Output Audible ala...

Page 6: ...ESPAN ESPAN04 Series User Manual 4 www esptechno com Dimension and Cut Out Relay Output Module...

Page 7: ...ond function is Function Test if push and hold this push button more than 3 seconds the LED lamp will start flicking and Bell Buzzer alarm This TEST push button is provided for checking purpose of all...

Page 8: ...de the momentary fault inputs will be latched until acknowledgement and reset to clear Alarm device is silenced lamp stop flashing and steady on when acknowledged command Manual reset of the alarm can...

Page 9: ...of fault input signal or filed contact Terminal X3 Pin 1 TEST must be connected to the lamp test LT push button switch which is N O contact and the opposite side of the P B switch must connect to COM...

Page 10: ...ESPAN ESPAN04 Series User Manual 8 www esptechno com Circuit Wiring Diagram Connection Diagram of ESPAN04 Connection Diagram of ESPAN04 Relay Output Module OPTION...

Page 11: ...re Configuration 1 After connect the notebook with the master module then apply the configuration software of ESPAN 04 V1 6 simply double click on setup icon as shown on the picture below then follow...

Page 12: ...ollowing picture 3 Communication Setup First of all users have to choose which com port that connect to ESPAN 04 Select setup menu which locate on the top of configuration program The setup window wil...

Page 13: ...he range of flashing rate starting from 125ms to 1000ms 125 ms per step 4 4 Modbus Setting User can choose address or change address of the master module as required 4 5 Input Time Delay User can choo...

Page 14: ...lected which are bell or buzzer or both 4 10 LED Color Type User can select color of LED indicator such as Red Green Amber Note All Parameters can be configured independently input by input except for...

Page 15: ...guration of all parameter of ESPAN 04 press WriteConfig button witch locate at the top right hand of the configuration window as shown as below picture 6 2 The program allow user to read configuration...

Page 16: ...ESPAN ESPAN04 Series User Manual 14 www esptechno com Configuration System for Serial Interface Modbus RTU TCP IP...

Page 17: ...ny Limited 76 82 Changwattana Rd Anusawari Bangkhen Bangkok 10220 Thailand Telephone 66 0 25226245 7 Fax 66 0 25226248 C Your equipments will be tested repaired and inspected at the factory and return...

Reviews: