Fitting the handset to the bracket
Locate the 4 lugs on the metal back plate, one located on each corner see Fig. 7,
these lugs must fit into the recesses on the rear of the hand set.
Place the handset over the metal back plate keeping the cables flat and out of
the way of the lugs.
Slide the hand set down into position engaging the 4 lugs on the back plate into
the recesses of the hand set.
Programming the Enterview VX Proximity Reader
All system programming requires the EVVX remote control. System programming
cannot be performed without it.
To enter programming mode press * # followed by the 4 digit programing code (The
factory default programming code: 4567) followed by #, the indication light on the
reader will change from red to amber and a long single confirmation tone will be heard.
It is mandatory to keep an on-site record of which user holds possession of
which numbered card/tag and what location number it is registered to. A
card/tag cannot be deleted from the system if the location number or the
whereabouts of the card/tag are unknown.
Adding User Cards/Tags using the card/tag numbers
Enter programming mode.
Press 1 - a single confirmation tone will be heard
Enter the last 6 digits of the new card/tag to be added, a single confirmation tone
will be heard.
To add further cards simply enter the last 6 digits of the next card.
If the error tone is emitted (4x beeps), this indicates that this card/tag is already
registered
Press the ** key to exit programming mode.
Adding User Cards/Tags by swiping
Enter programming mode.
Press 1 - a single confirmation tone will be heard