Technical Speci cation

Additional Accessories

EV-BPS – 12VDC 2 amp Multi output boxed power supply
EV-EBG – Emergency break glass
EV-EXIT – Push to exit button
EV-ML-250 – Electromagnetic lock

Enterview 5

Power

14.5 DC

Video Output 

1-1VP-P 750hm B/W PAL

Operating Temp.

-10/55ºC 

Consumption

800ma 

Dimensions (mm)

205x220x50

Enterview 5C

Power

14.5 DC

Video Output

1-1VP 750hm PAL 

Operating Temp.

-10/55ºC 

Consumption

800ma 

Dimensions (mm)

205x220x50

Enterview 5C-HF

Power

14.5 DC

Video Output

1-1VP 750hm PAL 

Operating Temp.

-10/55ºC 

Consumption

800ma 

Dimensions (mm)

240x175x38

EVHF10B / EVHF10W

Power

14.5 DC

Video Output

1-1VP 750hm PAL 

Operating Temp.

-10/55ºC 

Consumption

800ma 

Dimensions (mm)

340x210x38

Enterview 5 CAM

Power

14.5 DC

Video Output 

1-1VP-P 750hm B/W PAL

Min. Illumination

1 Lux

Operating Temp.

-10/55ºC 

Consumption

150ma 

Dimensions (mm)

55x130x40

Enterview 5 C-CAM

Power

14.5 DC

Video Output 

1-1VP-P 750hm PAL

Min. Illumination

1 Lux

Operating Temp.

-10/55ºC 

Consumption

150ma 

Dimensions (mm)

55x130x40

Enterview 5 KP

Power

14.5 DC

Video Output 

1-1VP-P 750hm B/W PAL

Min. Illumination

1 Lux

Operating Temp.

-10/55ºC 

Consumption

150ma 

Dimensions (mm)

75x190x45

Enterview 5 CKP

Power

14.5 DC

Video Output 

1-1VP-P 750hm PAL

Min. Illumination

1 Lux

Operating Temp.

-10/55ºC 

Consumption

150ma 

Dimensions (mm)

75x190x45

Enterview 5 Manual_Layout 2  16/10/2013  17:01  Page 12

Summary of Contents for Enterview 5

Page 1: ...VIDEO DOOR ENTRY SYSTEM INSTRUCTIONS...

Page 2: ...Door Wiring Configuration 5 Maximum Wiring Configuration 6 Additional Keypad and Magnetic Lock Wiring 7 Additional Keypad and Yale release Wiring 7 Keypad Commands 8 Installation Guide 9 Trouble Shoo...

Page 3: ...For a voltage free contact Keypad Camera requires a12VDC relay not supplied CAT5e cable specified for maximum distances 100 Meters maximum distance between outdoor station and furthest handset 10 Mete...

Page 4: ...C240 Wiring Configuration Standard Camera Keypad Camera See additional wiring instructions for Keypad 4 LOCK LOCK AC240 AC240 AC240 Keypad PSU provided 1 2 3 4 5 6 Handset PSUs provided Handset PSUs p...

Page 5: ...LY REMOVE FOR MULTIWAY OUTDOOR STATION CONNECTION 5 LOCK 1 2 3 4 5 6 LOCK AC240 AC240 Keypad PSU provided See additional wiring instructions for keypad AC240 AC240 Handset PSUs provided Handset Connec...

Page 6: ...6 Maximum Wiring Configuration AC240 AC240 AC240 AC240 AC240 AC240 LOCK See additional wiring instructions for keypad...

Page 7: ...a voltage free contact Keypad requires and additional 12VDC relay not supplied Back of Keypad camera MAGLOCK Additional Keypad and Yale release Wiring EGR Ov COM N O EXIT BUTTON AC240 Keypad PSU prov...

Page 8: ...e from an unknown group 1 Enter programming mode 2 Press two tones will sound 3 lnput 4 digit code to be deleted 4 Three tones will sound if successful 5 Press to exit Deleting all codes 1 Enter progr...

Page 9: ...9 Installation Guide EVH5 EVH5C EVH5C HF EVHF10W EVHF10B...

Page 10: ...10 Installation Guide EV5 CAM EV5 CCAM EV5KPCAM EV5CKPCAM Recommended installation height 150cm...

Page 11: ...ck of voltage and or cable run length The PSU s supplied with each monitor must be used and the cable length from PSU to monitor must not exceed 10m In multi apartment systems if more than one apartme...

Page 12: ...750hm PAL Operating Temp 10 55 C Consumption 800ma Dimensions mm 240x175x38 EVHF10B EVHF10W Power 14 5 DC Video Output 1 1VP 750hm PAL Operating Temp 10 55 C Consumption 800ma Dimensions mm 340x210x3...

Reviews: