background image

5

EZTAG3 Wiring Example 1

4
3

+

+

+

_

_

_

Red

NC

Black

Green

Purple

Grey

Pink

Electro-magnetic lock

Electronic lock

Tag Reader 

Indication LEDs

K

e

ypad

Tag Reader 

Indication LEDs

K

e

ypad

EZTAG3 Wiring Example 2

Red

Black

Green/White

Purple/White

Yellow

White

Blue/White

Output for

Lock 2

(Volt-free)

N.O

COM

N.C

Speaker connection

for ‘door bell’ facility

(8

 0.5w recommended) 

Input DC:

+12V - +24V

Input AC:

 12V -  24V

or

+
_

Grey

Orange

Pink

Push button 

for Lock 1 

(N.O) 

P.b for Lock 2 

(N.O) 

Green

Purple

Blue

Output for

Lock 1

(Volt-free)

N.O

COM

N.C

Lock -release time

N.C for 
Electro-magnetic lock

N.O for 
Electronic lock

Capacitor for 

Electro-magnetic lock

Diode for 

Electronic Lock

EZTAG3 Manual.qxp_Layout 1  04/01/2016  11:47  Page 5

Summary of Contents for Aperta

Page 1: ...U S E R M A N U A L w w w e s p u k c o m EZ TAG3 PROXIMIT Y AND KEYPAD DOOR ENTRY EZTAG3 Manual qxp_Layout 1 04 01 2016 11 47 Page 1...

Page 2: ...4 x Plastic wall plug 4 x Countersunk screws 1 x Diode and 1 x Capacitor Optional Accessories EVBPSBB Lock Power Supply EV EXIT Push to Release EV EBG Emergency Release EV ML 250 500XT Electro magnet...

Page 3: ...Programming Pin 7 Clear all Pin and Tag Data 8 Default to Factory Settings 8 Lock 1 Output Operating Time 9 Enable Door Bell Facility 9 Enable Tamper Alarm facility 10 Access Pin Number for Lock 2 Ou...

Page 4: ...ase from mount plate Release hex screw from the bottom of the keypad Thread system cable through the cable entry hole then make the system connections as per the wiring diagram mount the bracket to th...

Page 5: ...e White Output for Lock 2 Volt free N O COM N C Speaker connection for door bell facility 8 0 5w recommended Input DC 12V 24V Input AC 12V 24V or _ Grey Orange Pink Push button for Lock 1 N O P b for...

Page 6: ...Double 9 9 9 ags ess T Ta c c A up ow to set H ction A Number tep S 9 0 5 1 5 4 3 2 0 0 0 9 location number ter a unused En ed egister tags to be r ter number of En ogramming Pr ter En Default 1 2 3...

Page 7: ...L 9 9 2 3 4 ogramming Pin Changing Pr ction A Number tep S 3 5 4 3 2 1 ogramming Pr ter En ogramming o end pr T To ogramming pin pr w 4 digit ter ne En ogramming pin pr w 4 di ter ne e en R Default 1...

Page 8: ...1 Default 1 2 3 4 1 2 Indication ypad e K one T To ong L 2 3 4 one T To ong L actory Settings Default to F ction A Number tep S 8 9 9 ogramming Pr ter En ogramming o end pr To 4 3 2 1 Default 1 2 3 4...

Page 9: ...ication ypad e K one T To ong L 2 3 4 one T To ong L acility Enable Door Bell F ction A Number tep S 2 ogramming Pr ter En ogramming o end pr T To 4 3 2 1 0 2 o enable To door bell push in normal mode...

Page 10: ...1 2 0 1 o T To Indication ypad e K one T To ong L 2 3 4 e one T To ong L o disable or Lock 2 Output ess Pin Number f c c A ction A Number tep S 9 0 3 5 4 3 2 1 t be used 1234 should no ter a 4 digit...

Page 11: ...mming o end pr T To 0 0 0 4 5 Indication ypad e K 2 3 4 one T To ong L 0 9 or Lock Lock Output Operating Time f ction A Number tep S 5 onds 00 99 of sec ter number En ogramming Pr ter En ogramming o e...

Page 12: ...assist in future programming it is recommended that a record is made of the system setup System Location Tag Serial Tag Owner Notes Number 000 999 Number EZTAG3 Manual qxp_Layout 1 04 01 2016 11 47 Pa...

Page 13: ...13 System Location Tag Serial Tag Owner Notes Number 000 999 Number EZTAG3 Manual qxp_Layout 1 04 01 2016 11 47 Page 13...

Page 14: ...ss pr c o ac T To Default 1 2 3 4 1 2 3 4 User Guide Technical Specification DC input 12 24volts AC input 12 24volts Standby current 80ma Operating current without lock 110ma Working temperature 20c t...

Page 15: ...15 EZTAG3 Manual qxp_Layout 1 04 01 2016 11 47 Page 15...

Page 16: ...ecurity Products Unit 7 Target Park Shawbank Rd Lakeside Redditch B98 8YN Telephone 01527 51 51 50 Fax 01527 51 51 43 email info espuk com E OE Errors and omissions excepted L15 EZTAG3 Manual qxp_Layo...

Reviews: