11

Installer’s Guide 

When using multiple monitors on 1 system; 

Only the 1 handset set as the MASTER will display an image when the door station is activated.

All other monitors will ring, and will display the image once the ‘Talk’ button is pressed.

A   That the system is powered sufficiently.

B    Each monitor needs to be set to a MASTER or SLAVE position

C   All system cabling is secured and properly connected.

D   All system cabling is clear of breaks or short circuits.

E   Bench test the system if the issue cannot be found.

A   The user instructions and operation of the monitor has been understood.

B   That the lock is powered sufficiently.

C   All system cabling is secured and properly connected.

D   All system cabling is clear of breaks or short circuits.

E   On the rear of the door station, ensure the lock output is switching when activated by the monitor.

Master / Slave Setting

In the event of no video

or audio signals coming 

from the monitor, or if the 

call button or audio cannot 

be activated on the door 

station, check the following; 

In the event of a lock 

release issue, 

check the following;

APKITKPBLK Manual.indd   11

26/04/2017   10:00:23

Summary of Contents for Aperta APKITKPBLK

Page 1: ...U S E R M A N U A L w w w e s p u k c o m A P K I T K P B L K C O L O U R V I D E O D O O R E N T R Y S Y S T E M APKITKPBLK Manual indd 1 26 04 2017 10 00 15...

Page 2: ...online elandcables com Cables Accessories LAN Cable Cat 5E UTP PVC Cable Contents System Components 3 Installation 4 System Connections Example 1 5 System Connections Example 2 6 Lock Connections Exa...

Page 3: ...on Monitor EVBPSBB Lock Power Supply EV EXIT Push To Release EV EBG Emergency Release EV ML 250 500XT Electro magnetic Lock ENTERD Electric Lock Optional Accessories System Power Supply APKITKPBLK Man...

Page 4: ...The camera needs to point in the direction of where a visitor will stand during operation Site the indoor monitor to suit application Monitor 1 Gang Mount Box if required not supplied Surface mount t...

Page 5: ...xample 1 Dip switch 6 set to ON when device is at the end of system line Dip switch 7 set to OFF to select monitor as the Master Only one monitor on the system can be the Master APKITKPBLK Manual indd...

Page 6: ...em line has dip switch 6 set to ON END OF LINE 6 4 When using different style monitors on the same system please refer to supplied instruction to configure Master Slave and End of line position END OF...

Page 7: ...MAX 1 2 3 J1 J2 J3 1 2 3 J1 J2 J3 1 2 3 J1 J2 J3 1 2 3 J1 J2 J3 1 2 3 J1 J2 J3 1 2 3 J1 J2 J3 Image of jumper link The jumpers on the rear of the door station offer different types of release modes fo...

Page 8: ...ode Default 123456 2 tones will sound 2 tones will sound Press Setting a lock release code The Administrator code will not release the door A lock release code is required to be programmed Administrat...

Page 9: ...und Press Changing the Administrator code Enter code Location Number A long tone will sound Press Press Press Press to exit and complete setup Press to exit and complete setup A long tone will sound P...

Page 10: ...roma Adjustment for the intensity of colour Talking Volume Adjust the volume level of the monitor Press the Talk button to end call Press the Lock button to release lock and press Talk to end call Pre...

Page 11: ...E Bench test the system if the issue cannot be found A The user instructions and operation of the monitor has been understood B That the lock is powered sufficiently C All system cabling is secured an...

Page 12: ...e Security Products Unit 7 Target Park Shawbank Rd Lakeside Redditch B98 8YN Telephone 01527 51 51 50 Fax 01527 51 51 43 email info espuk com E OE Errors and omissions excepted D17 APKITKPBLK Manual i...