ESP Aperta APDSSW User Manual Download Page 10

10

Installer’s Guide 

When using multiple monitors on 1 system;
Only the 1 handset set as the MASTER will display an image when the door station is activated.
All other monitors will ring, and will display the image once the ‘Talk’ button is pressed.

A   That the system is powered sufficiently.
B   Each monitor needs to be set to a MASTER or SLAVE position
C   All system cabling is secured and properly connected.
D   All system cabling is clear of breaks or short circuits.
E   Bench test the system if the issue cannot be found.

A   The user instructions and operation of the monitor has been understood.
B   That the lock is powered sufficiently.
C   All system cabling is secured and properly connected.
D   All system cabling is clear of breaks or short circuits.
E   On the rear of the door station, ensure the lock output is switching when activated by the monitor.

Master / Slave Setting

In the event of no video
or audio signals coming 

from the monitor, or if the 

call button or audio cannot 

be activated on the door 

station, check the following; 

In the event of a lock 

release issue, 

check the following;

APDSSW manual.qxp_Layout 1  29/01/2016  13:01  Page 10

Summary of Contents for Aperta APDSSW

Page 1: ...U S E R M A N U A L w w w e s p u k c o m A P D S S W S I N G L E W A Y V I D E O D O O R S T A T I O N APDSSW manual qxp_Layout 1 29 01 2016 13 00 Page 1...

Page 2: ...d this product online elandcables com Cables Accessories LAN Cable Cat 5E UTP PVC Cable Contents System Components 3 Installation 4 System Connections Example 1 5 System Connections Example 2 6 Lock C...

Page 3: ...es APMONW APMONB Monitor white black APMONWG APMONBG Monitor white black EVBPSBB Lock Power Supply EV EXIT Push To Release EV EBG Emergency Release EV ML 250 500XT Electro magnetic Lock ENTERD Electri...

Page 4: ...th the supplied hex screw 90 1 2 m 1 5 m Avoid areas of high sunlight and noise levels The camera needs to point in the direction of where a visitor will stand during operation Site the door station a...

Page 5: ...olarity Ensure the Address ID switches are both set to OFF Address ID 01 Total cable run should not exceed 150 meters between door station and monitor MASTER Refer to instructions supplied with monito...

Page 6: ...itor BUS BUS BUS BUS Address ID 01 Address ID 02 BUS BUS POWER SUPPLY 240vAC INPUT The dipswitches are accessable on the rear of the door station Address ID 02 Address ID 03 Address ID 01 Address ID 0...

Page 7: ...J3 and J2 positions 1 2 3 J1 J2 J3 NC 4 3 _ _ _ Electro magnetic lock Electronic lock BUS System Wiring LOCK1 VCC J1 Image of jumper link Lock release time N C for Electro magnetic lock N O for Elect...

Page 8: ...ives the option to set the release time 5 sec 3 sec The door station has a secondry switch LOCK2 options Please refer to the operation guide for release instructions 1 2 3 J1 J3 J2 1 2 3 J1 J3 J2 1 2...

Page 9: ...to release lock 2 and press Talk to end call The visitor presses the call button A chime will sound The visitor s image will appear on the monitor Press the Talk button and begin conversation Then ch...

Page 10: ...ench test the system if the issue cannot be found A The user instructions and operation of the monitor has been understood B That the lock is powered sufficiently C All system cabling is secured and p...

Page 11: ...11 APDSSW manual qxp_Layout 1 29 01 2016 13 01 Page 11...

Page 12: ...ecurity Products Unit 7 Target Park Shawbank Rd Lakeside Redditch B98 8YN Telephone 01527 51 51 50 Fax 01527 51 51 43 email info espuk com E OE Errors and omissions excepted A16 APDSSW manual qxp_Layo...

Reviews: