7
WORD CLOCK OUT terminals
These terminals output precise word synchronization signals. Connect these OUT terminals to the
WORD SYNC IN terminals of the other digital equipment, using a commercially available BNC
coaxial cable.
<
For other connections, read the instructions of each component you intend to use with this unit.
<
Each of the A, B, and C channels is switch-selectable between 1xFs, 2xFs, and 4xFs. So you can,
for example, connect an 88.2 kHz and a 176.4 kHz machine to the single G-0s and synchronize
them. Three buttons (A, B, and C) are provided on the front panel for each channel.
UNIVERSAL CLOCK OUT terminal
Universal clock signal is an original synchronization format developed by TEAC-Esoteric.
These terminals output universal clock signals. Connect these OUT terminals to the UNIVERSAL
CLOCK IN terminals of the other matched equipment (ex. UX-1, P-01,etc.), using a commercially
available BNC coaxial cable.
10MHz IN terminal
You can use the input of external 10MHz reference frequency. Connect this terminal to the
output terminal of the external 10MHz oscillator. Use a commercially available BNC coaxial cable
for connection.
SIGNAL GND connection
Use a commercially available PVC-covered cord to connect the signal ground terminal on the unit
to the amplifier signal ground.
<
Note that this is NOT an electrical safety ground (earth).
Power cord receptacle
After all other connections have been made, insert the supplied AC power cord into this
receptacle, then connect the other end of the power cord into the AC power source. Ensure that
your AC voltage corresponds to the voltage marked on the rear panel of the unit. Consult a
qualified electrician if you are in doubt.
<
In order to avoid the risk of electric shock, fire, or other hazard, only use the supplied power cord
or a suitably approved OEM power cord.
<
If you are not going to use the unit for some time, disconnect the power cord from the wall
socket.
Main Power switch
Use this to turn the unit on and off.
<
When the G-0s is turned on, the process of pre-heating the rubidium oscillator to its operating
temperature gets started. It takes several minutes before the oscillator is ready for operation.
Keep the unit turned on if you want the oscillator to stabilize more quickly.
F
E
D
C
B
A
The equipment draws nominal non-operating power from the AC outlet with its POWER switch
in the OFF position.