WORD CLOCK OUT terminals 

These terminals output precise word synchronization signals. Connect these OUT terminals to the
WORD SYNC IN terminals of the other digital equipment, using a commercially available BNC
coaxial cable.

<

For other connections, read the instructions of each component you intend to use with this unit.

<

Each of the A, B, and C channels is switch-selectable between 1xFs, 2xFs, and 4xFs. So you can,
for example, connect an 88.2 kHz and a 176.4 kHz machine to the single G-0s and synchronize
them. Three buttons (A, B, and C) are provided on the front panel for each channel.

UNIVERSAL CLOCK OUT terminal 

Universal clock signal is an original synchronization format developed by TEAC-Esoteric. 
These terminals output universal clock signals. Connect these OUT terminals to the UNIVERSAL
CLOCK IN terminals of the other matched equipment (ex. UX-1, P-01,etc.), using a commercially
available BNC coaxial cable.

10MHz IN terminal 

You can use the input of external 10MHz reference frequency. Connect this terminal to the
output terminal of the external 10MHz oscillator. Use a commercially available BNC coaxial cable
for connection.

SIGNAL GND connection

Use a commercially available PVC-covered cord to connect the signal ground terminal on the unit
to the amplifier signal ground.

<

Note that this is NOT an electrical safety ground (earth).

Power cord receptacle

After all other connections have been made, insert the supplied AC power cord into this
receptacle, then connect the other end of the power cord into the AC power source. Ensure that
your AC voltage corresponds to the voltage marked on the rear panel of the unit. Consult a
qualified electrician if you are in doubt.

<

In order to avoid the risk of electric shock, fire, or other hazard, only use the supplied power cord
or a suitably approved OEM power cord.

<

If you are not going to use the unit for some time, disconnect the power cord from the wall
socket.

Main Power switch

Use this to turn the unit on and off.

<

When the G-0s is turned on, the process of pre-heating the rubidium oscillator to its operating
temperature gets started. It takes several minutes before the oscillator is ready for operation.
Keep the unit turned on if you want the oscillator to stabilize more quickly.

F

E

D

C

B

A

The equipment draws nominal non-operating power from the AC outlet with its POWER switch
in the OFF position.

Summary of Contents for G-0s

Page 1: ...Master Clock Generator Owner s Manual G 0s...

Page 2: ...he manufacturer 12 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combinat...

Page 3: ...n the amplifier receiver Do not open the cabinet as this might result in damage to the circuitry or electrical shock If a foreign object should get into the unit contact your dealer or service company...

Page 4: ...output intended for universal players in PAL FILM mode the output is switched to 96 kHz If your universal players are 100 kHz capable you can control them by this high precision clock PAL Film Source...

Page 5: ...e FREQUENCY MODE is set to 44 1kHz or 48kHz the frequency of the universal clock is set to 100kHz When the FREQUENCY MODE is set to PAL FILM the frequency of the universal clock is set to 96kHz When O...

Page 6: ......

Page 7: ...mercially available BNC coaxial cable for connection SIGNAL GND connection Use a commercially available PVC covered cord to connect the signal ground terminal on the unit to the amplifier signal groun...

Page 8: ...n Press the STANDBY ON button to turn the unit on 2 1 The standby indicator will turn off Press the MASTER button to select which oscillator you will use for the reference frequency 3 Rb is recommende...

Page 9: ...he FREQUENCY MODE button 4 3 2 1 48kHz If you intend to play DVD DAT etc 44 1kHz If you intend to play CD PAL FILM If you intend to play PAL DVD discs at 24frames sec Before you set PAL FILM mode conf...

Page 10: ...nel Not synchronized e Check to see if the current word clock output is supported by the connected players If necessary select a word clock frequency that is appropriate for the individual players The...

Page 11: ...m oscillator is stabilized 0 seconds MASTER FREQUENCY MODE switched to output stabilized Less than 10 seconds Frequency input Input 10 MHz under 10 ppm Rectangular or Sine wave 1 4 5 V peak to peak Te...

Page 12: ...ne 905 890 8008 TEAC MEXICO S A De C V Campesinos N 184 Colonia Granjas Esmeralda Delegacion Iztapalapa CP 09810 M xico DF Phone 525 581 5500 TEAC UK LIMITED 5 Marlin House Croxley Business Park Watfo...

Reviews: