background image

Operating Manual

Solar Pumps Turin, Modena and Riviera

These instructions relate ONLY to this product and contain important infor-

mation for using the product for the first time. Please keep these instructions 

for later reference and should always accompany the product in the event of 

transference to a new user.

1. Introduction

Dear Costumer, thank you for purchasing the solar pump kit. 

With this solar pump kit you purchased a product manufactured according to the 

current state of technology. 

This product fulfils all requirements of the valid European and nati-

onal regulations. The conformity was proved. The relevant declara-

tions and documentation are deposited with the manufacturer. 

To maintain this state and guarantee a safe operation, you as the user will have to 

follow this operating manual!

2. Safety Instructions

  

- In case of damages caused by not following 

   

  this operating manual, the warranty rights will expire!

 

  We exclude liability for any consequential damages!

 

- We exclude liability for property or personal damages

 

  caused by inappropriate handling or not following the

 

  safety instructions. 

 

- In these cases any guarantee rights will expire.

Due to safety and admission reasons (CE) it is not allowed to arbitrarily reconstruct 

and/or change the solar pump kit. 

Therefore, please keep to the operating manual. 

The accident prevention rules of the association of the industrial trade cooperative 

association for electric plants and working material are to be considered in industrial 

environments

3. Appropriate use

This submersible pump has been constructed for pumping water into garden ponds, 

water fountains, etc.. The pumping can be conducted via a hose attachment or via 

the supplied standpipes with water sprinklers. 

A solar module featuring a voltage of 12 - 24 volts can be used as the source of ener-

gy. When using such a solar module, the pump only works when the solar module 

has been provided with enough of the sun’s rays. 

The pumping performance can be set using the regulator on the front side of the 

pump. The water pump does not feature an on/off switch. As soon as the pump is 
connected with its electrical supply, it will begin pumping water. 

4. Assembly and start-up procedure

1. 

Completely unroll the connecting cable at the pump. 

2. 

Attach the ascending pipes onto the pump or connect a hose to the outlet of the 

pump. If the ascending pipes are used it is possible to attach a water sprinkler or 

water bell. A step sprinkler and a water bell are included in the scope of delivery. 

3. 

Put the pump into the water. In doing so, please make sure that the pump is 

not directly placed on the pond bottom. Because at the bottom of the pond is 

the greatest contamination which would lead to a clogging of the nozzle holes. 

Place the pump onto a stone or platform in the pond. 

4. 

Now power the water pump by means of a solar module, battery or direct current 

power pack. For this purpose, please use the enclosed plug including cable 

(brown = positive pole, blue = negative pole). 

5. 

In case you bought this pump as a complete solar system in one set, then the 

matching plug is already installed in the solar module.  

Note: 

The plug is protected against reverse 

polarity; please do not apply force when 

plugging it in.   

1. 

Connecting cable

2. 

Adapter for the connection to power 

packs or batteries (not included in the 

set with a solar module)

3. 

Ascending pipes

4. 

Water bell

5. 

Water sprinkler

5. Care and Maintenance

In order to maintain the performance of the pump it is required to occasionally, 

depending on the water contamination, rinse the pump with warm water. For this 

purpose, open the filter housing as follows:

Note:

 Please do not apply force when assembling and disassembling the pump. The 

parts are very delicate and may break easily. If required, spare parts are available 

under   www.esotec.de.

1. 

Disconnect the plug from the pump.

2. 

Remove the ascending pipe or the hose and take the pump out of the water. 

3. 

Slightly rotate the coarse filter anticlockwise and take off the front part (figure 1). 

A certain amount of force is required in order to loosen the snap lock. 

4. 

Remove the bottom plastic slide forward (figure 2), rotate the front cover of the 

pump by approx. 45° anticlockwise (figure 3) and carefully remove the cover 

forward (figure 4). In doing so, please pay attention to the ceramic shaft and the 

rubber plug, this shaft may break easily or get lost. 

5. 

Carefully pull the impeller wheel with the plastic shaft out of the pump (figure 5). 

6. 

Now carefully clean all parts with warm water.  

7. 

Now reassemble the pump in reverse order and pay attention to the correct fit of 

the ceramic shaft and sealing gasket (figure 5).  

6. Technical Data

Pump type:   

Turin 

Modena 

Riviera

Set-Art.-No.: 

 

 

101680 101681 101682

Operating voltage: 

12 VDC 

12V-24 VDC 

12V-24 VDC

Discharge head/flow rate 12 VDC:   max. 0.8m/470 l/h  max. 0.8m/470l/h  max. 0,8m/980l/h

Discharge head/flow rate 17 VDC:    -- 

max. 1.5m/610 l/h  max. 1.9m/1350l/h

Discharge head/flow rate 24 VDC:    -- 

max. 2m/750l/h 

max. 3m/1560l/h

Power consumption 12V/17V/24V:  2,5W/-/- 

2W/7W/12W 

3W/11.5W/21.5W

Protection class: 

IP 68 

IP 68 

IP 68

Operating temperature: 

+4°C to +40°C 

+4°C to +40°C 

+4°C to +40°C

Cable length:   5 m 

5 m 

5 m 

5 m

Minimum output solar module: 

5 Wp (24 cells) 

10 Wp (36 cells) 

20 Wp (36 cells)

Note: The pump is only suitable for the delivery of water. 

Note: Protect the pump against frost! 

During cold winter months, it is required to take the pump out of the water and store it at a 

frost-free place. The solar module may be left outside during the winter.   

7. Safety information:

DANGEROUS for children! Children could easily swallow the small parts that come 

with this pump and its packaging material. Please keep at a safe distance. These 

parts could otherwise lead to choking or suffocation!

WARNING against danger of stumbling! Lay out the connection cable such that it 

does not create the threat of tripping or stumbling!

CAREFUL: material damage! If you set up the solar module without a module hold-

er, you must make sure that it is sturdy enough to retain its position. If the module falls 

down or a foreign object hits against it, the solar module can be damaged. 

Notes on disposal for electronic devices:

Esteemed customer, once you have decided to part ways with this article, 

please dispose of it in accordance with the current, local law. Information is 

provided by the municipal appointment. 

Manufacturer/ importer/ Spare parts: 

esotec GmbH  -  Gewerbegebiet Weberschlag 9  -  D-92729 Weiherhammer

Tel.-Nr: +49 9605-92206-0 

 

Fax.-Nr: +49 9605-92206-10

e-mail:[email protected]        

 