Operating manual Water pump
„Genova“
These instructions relate ONLY to this product and contain important infor-
mation for using the product for the first time. Please keep these instructions
for later reference and should always accompany the product in the event of
transference to a new user.
1. Introduction
Dear Costumer,
Thank you for purchasing the water pump. With this water pump you purchased
a product manufactured according to the current state of technology.
This product fulfils all requirements of the valid European and
national regulations. The conformity was proved. The relevant
declarations and documentation are deposited with the manu-
facturer.
To maintain this state and guarantee a safe operation, you as the user will have
to follow this operating manual!
2. Safety Instructions
- In case of damages caused by not
following this operating manual, the
warranty rights will expire! We exclude
liability for any consequential damages!
- We exclude liability for property or
personal damages caused by inappropriate
handling or not following the safety instructions.
- In these cases any guarantee rights will expire.
Due to safety and admission reasons (CE) it is not allowed to arbitrarily recon-
struct and/or change the water pump.
Therefore, please keep to the operating manual.
The accident prevention rules of the association of the industrial trade coope-
rative association for electric plants and working material are to be considered
in industrial environments.
3. Intended Use
This submergible pump is designed for the pumping of water in the garden
pond, fountain, water trays or similar. It can pump water via a gland or it may be
operated via enclosed ascending pipes with water sprinklers.
A solar module or a power supply unit with a voltage of 12 - 24 Volts can be used
as energy source. If used in combination with a solar module the pump will only
work if the solar module is exposed to sufficient solar radiation.
The delivery rate of the pump can be adjusted via the controller on the front side
of the pump. The water pump does not have any ON/OFF-switch. The pump
starts pumping water as soon as it is connected to the power supply.
4. Overview
1. Ascending pipes
2. Water nozzle with a 3-stage sprinkler
3. Water nozzle for the water bell
4. Water-Air nozzle
5. Controller for the delivery rate
6. 5 m Connecting cable including plug
7. Locking for the pump case
8. Connecting cable with open ends
(only included in single pumps and not in sets)
5. Assembly and Start-up
1.
Completely unroll the connecting cable on the pump.
2.
Measure the depth of water of your garden pond.
3.
Firmly connect the individual ascending pipes until the pipe protrudes from the
water surface. In case the enclosed ascending pipes should not be sufficient,
you may also order those pipes as spare parts from the manufacturer. Now
attach the sprinkler you want to use.
•
Note: When using the water bell it is possible to adjust the diameter of the bell
by screwing in or out of the upper part.
•
Note: Please make sure that the pump is not directly placed on the pond
bottom. A particularly high amount of dirt is sucked in here which would lead to
a fast clogging of the nozzles. Therefore, please place the pump approximately
20 cm above the pond bottom onto stones.
4.
Depending on the use, the pump may be operated directly via a solar module, a
battery box or a DC power supply unit (12 to 24 VDC) and or a solar battery. Now
connect the plug with the socket on the solar module or the battery box. A cable
piece with open ends is included in the scope of delivery for the connection to a
power supply unit or battery. Please note that, in this case, the brown cable is
the positive pole and the blue cable is the negative pole.
•
Note: The plug is protected against reverse polarity; please do not apply force
when plugging it in.
5.
If the delivery rate of the pump should be too high, you
may reduce the amount of water. For this purpose, simply
rotate the controller at the front side of the pump clockwise.
Do not apply force when adjusting. The adjustment range
amounts to 45°.
6. Protection against dry Running
The pump is standard-equipped with a protection
against dry running. 2 sensor points at the side of the
case are installed for this purpose. The pump will work
if those points are under water. The pump won’t work
if one point should protrude from the water!
Those points have to be cleaned with a sponge and
water when servicing or cleaning the pump.
7. Service and Maintenance
In order to maintain the performance of the pump it is required to
occasionally, depending on the water contamination, rinse the pump with
warm water. For this purpose, open the case as follows:
Note: Please do not apply force when assembling and disassembling the
pump. The parts are very delicate and may break easily.
1. Disconnect the power supply of the pump
2. Remove the ascending pipe from the pump.
3. Push the two lateral locks into the position „OPEN“ and take if off to
the side.
4. Carefully open the pump case.
5. Take the pump out of the case.
6. Rotate the front cover of the pump by approx. 45° clockwise (illustration
1) and carefully pull the cover to the front (illustration 2). In doing so,
please
pay attention to the ceramic shaft and the seal.
!
GB
Customer support:
If you have problems or questions regarding this product, simply contact us!
Monday to Friday 9 am to 12 noon and 1 pm to 4 pm.
By phone: 09605-92206-0
By e-mail for ordering spare parts: [email protected]
By e-mail for questions about the product: [email protected]
Product: Manufacturer Item No.: 101735
flow rate
100%
0%
sensorpoints
1
2
3
5
6
7
1
4
8
Pic. 1
Pic. 2
Pic. 3