background image

Operating manual 

solar water pump „25/ 1600“

These instructions relate ONLY to this product and contain important infor-

mation for using the product for the first time. Please keep these instructions 

for later reference and should always accompany the product in the event of 

transference to a new user.

1. Introduction

Dear Costumer, 

Thank you for purchasing the solar light. With this solar light you purchased a product 

manufactured according to the current state of technology. 

This product fulfils all requirements of the valid European and national 

regulations. The conformity was proved. The relevant declarations and 

documentation are deposited with the manufacturer. 

To maintain this state and guarantee a safe operation, you as the user will 

have to follow this operating manual!

2. Safety Instructions

  

- In case of damages caused by not 

  

  following this operating manual, the 

 

  warranty rights will expire! We exclude 

 

  liability for any consequential damages!

 

- We exclude liability for property or 

 

  personal damages caused by inappropriate 

  

  handling or not following the safety instructions. 

- In these cases any guarantee rights will expire.

Due to safety and admission reasons (CE) it is not allowed to arbitrarily reconstruct 

and/or change the solar light. 

Therefore, please keep to the operating manual. 

The accident prevention rules of the association of the industrial trade cooperative 

association for electric plants and working material are to be considered in industrial 

environments.

3. Intended use

This submersible pump is designed for pumping water in garden ponds, fountains, 

water dishes, etc.  It can pump water through a hose connection or can be operated 

through attached lifting tubes with water sprinklers. 

The delivery rate of the pump can be adjusted using the regulator on the front side of 

the pump. The water pump has no On/Off switch. As soon as the pump is connected 

to its power supply, it starts pumping water. 

4. Installation and commissioning

1.   Roll out the connecting cable of the pump completely. 

2.   Screw the hose adapter on the pump. Depending on used tube diameter, it may 

be necessary that this must be shortened. Attach the hose with an appropriate 

clamp. 

3.   Set the pump into the water. 

4.   Supply now the water pump with energy by a solar module. Connect to the socket 

of the pump ind the plug of the solar module and screw the cap on firmly. 

Note: 

The plug has reverse-polarity protection, no force should be used while inser-

ting. The glass of the solar module is fragile. 

Caution! Risk of injury!  A broken module cannot be repaired again and must be 

disposed off in an environmental-friendly way. 

8.  If the pumping capacity is 

too high, you can reduce 

the amount of water. 

Simply turn the regulator 

on the front side of the 

pump in clockwise direc-

tion.  Please do not use 

force while adjusting. The 

adjustment range is 45°. 

5

. Care and maintenance 

For optimum performance of the pump, it must be washed occasionally with warm 

water depending on the water contamination. To wash the pump, open the housing 

as follows:

Note: 

Please do not use force while dismantling or assembling the pump. The parts 

are very fragile and can break easily. 

1.  Disconnect the pump’s plug. 

2.   Pull the front cover of the pump forward like a slide gently (Figure 1).  

3.   Turn the front cover of the pump by about 45° clockwise (Figure 1) and carefully 

pull the cover forward (Figure 2).  Watch out for the plastic shaft and the seal while 

doing this.

4.   Carefully drag the impeller out of the pump (if necessary, use pliers).  (Figure 3). 

5.   Now clean all the parts carefully with warm water.  

6.   Then plug the shaft with the impeller carefully into the hole of the pump. Ensure 

that the shaft is fitted firmly.

7.   Now place the cover carefully over the pump. Ensure that the seal is fitted proper-

ly. 

8.   Turn the front cover again by 45 degrees counter-clockwise into the starting posi-

tion. 

9.   Slide the lower part of the pump completely into the pump housing. 

The pump is ready to use again.

6. Malfunction

Pump is not pumping water

- Is the pump completely submerged in water? 

- Is the pump dirty? Cleaning the pump, see Point 5.

7. Technical data

- Operating voltage: 

18 V DC

- Degree of protection:        IP 68 

- Class of protection:  

III 

- Power consumption:  

15 - 20 W

- Pump lift: 

Max. 2,3 m

- Delivery rate:  

Max. 1600 l/h

- Operating temp. range:    +4 to +40°C

Note:

 The pump is only suitable for pumping water. 

Note:

 Protect the pump from frost! 

During cold winter months, the pump must be taken out of the water and placed/

stored in a warm area. The solar module can spend the winter outdoors. 

8. Safety information:

DANGEROUS for children!

 Children could easily swallow the small parts that come 

with this pump and its packaging material. Please keep at a safe distance. These 

parts could otherwise lead to choking or suffocation!

WARNING against danger of stumbling!

 Lay out the connection cable such that it 

does not create the threat of tripping or stumbling!

CAREFUL: material damage! 

If you set up the solar module without a module hold-

er, you must make sure that it is sturdy enough to retain its position. If the module falls 

down or a foreign object hits against it, the solar module can be damaged. 

!

GB

Customer support:

  If you have problems or questions regarding this product, simply contact us!  

  

Monday to Friday 8 am to 12 noon and 1 pm to 4 pm.

  By phone: 09605-92206-0

  By e-mail for ordering spare parts: 

[email protected]

  By e-mail for questions about the product: 

[email protected]

  Product: Manufacturer Item No.: 101018

turn 45°

1

2

3

flowrate 

regulator

hose connector

Reviews: