Operating manual
solar water pump „25/ 1600“
These instructions relate ONLY to this product and contain important infor-
mation for using the product for the first time. Please keep these instructions
for later reference and should always accompany the product in the event of
transference to a new user.
1. Introduction
Dear Costumer,
Thank you for purchasing the solar light. With this solar light you purchased a product
manufactured according to the current state of technology.
This product fulfils all requirements of the valid European and national
regulations. The conformity was proved. The relevant declarations and
documentation are deposited with the manufacturer.
To maintain this state and guarantee a safe operation, you as the user will
have to follow this operating manual!
2. Safety Instructions
- In case of damages caused by not
following this operating manual, the
warranty rights will expire! We exclude
liability for any consequential damages!
- We exclude liability for property or
personal damages caused by inappropriate
handling or not following the safety instructions.
- In these cases any guarantee rights will expire.
Due to safety and admission reasons (CE) it is not allowed to arbitrarily reconstruct
and/or change the solar light.
Therefore, please keep to the operating manual.
The accident prevention rules of the association of the industrial trade cooperative
association for electric plants and working material are to be considered in industrial
environments.
3. Intended use
This submersible pump is designed for pumping water in garden ponds, fountains,
water dishes, etc. It can pump water through a hose connection or can be operated
through attached lifting tubes with water sprinklers.
The delivery rate of the pump can be adjusted using the regulator on the front side of
the pump. The water pump has no On/Off switch. As soon as the pump is connected
to its power supply, it starts pumping water.
4. Installation and commissioning
1. Roll out the connecting cable of the pump completely.
2. Screw the hose adapter on the pump. Depending on used tube diameter, it may
be necessary that this must be shortened. Attach the hose with an appropriate
clamp.
3. Set the pump into the water.
4. Supply now the water pump with energy by a solar module. Connect to the socket
of the pump ind the plug of the solar module and screw the cap on firmly.
Note:
The plug has reverse-polarity protection, no force should be used while inser-
ting. The glass of the solar module is fragile.
Caution! Risk of injury! A broken module cannot be repaired again and must be
disposed off in an environmental-friendly way.
8. If the pumping capacity is
too high, you can reduce
the amount of water.
Simply turn the regulator
on the front side of the
pump in clockwise direc-
tion. Please do not use
force while adjusting. The
adjustment range is 45°.
5
. Care and maintenance
For optimum performance of the pump, it must be washed occasionally with warm
water depending on the water contamination. To wash the pump, open the housing
as follows:
Note:
Please do not use force while dismantling or assembling the pump. The parts
are very fragile and can break easily.
1. Disconnect the pump’s plug.
2. Pull the front cover of the pump forward like a slide gently (Figure 1).
3. Turn the front cover of the pump by about 45° clockwise (Figure 1) and carefully
pull the cover forward (Figure 2). Watch out for the plastic shaft and the seal while
doing this.
4. Carefully drag the impeller out of the pump (if necessary, use pliers). (Figure 3).
5. Now clean all the parts carefully with warm water.
6. Then plug the shaft with the impeller carefully into the hole of the pump. Ensure
that the shaft is fitted firmly.
7. Now place the cover carefully over the pump. Ensure that the seal is fitted proper-
ly.
8. Turn the front cover again by 45 degrees counter-clockwise into the starting posi-
tion.
9. Slide the lower part of the pump completely into the pump housing.
The pump is ready to use again.
6. Malfunction
Pump is not pumping water
- Is the pump completely submerged in water?
- Is the pump dirty? Cleaning the pump, see Point 5.
7. Technical data
- Operating voltage:
18 V DC
- Degree of protection: IP 68
- Class of protection:
III
- Power consumption:
15 - 20 W
- Pump lift:
Max. 2,3 m
- Delivery rate:
Max. 1600 l/h
- Operating temp. range: +4 to +40°C
Note:
The pump is only suitable for pumping water.
Note:
Protect the pump from frost!
During cold winter months, the pump must be taken out of the water and placed/
stored in a warm area. The solar module can spend the winter outdoors.
8. Safety information:
DANGEROUS for children!
Children could easily swallow the small parts that come
with this pump and its packaging material. Please keep at a safe distance. These
parts could otherwise lead to choking or suffocation!
WARNING against danger of stumbling!
Lay out the connection cable such that it
does not create the threat of tripping or stumbling!
CAREFUL: material damage!
If you set up the solar module without a module hold-
er, you must make sure that it is sturdy enough to retain its position. If the module falls
down or a foreign object hits against it, the solar module can be damaged.
!
GB
Customer support:
If you have problems or questions regarding this product, simply contact us!
Monday to Friday 8 am to 12 noon and 1 pm to 4 pm.
By phone: 09605-92206-0
By e-mail for ordering spare parts:
By e-mail for questions about the product:
Product: Manufacturer Item No.: 101018
turn 45°
1
2
3
flowrate
regulator
hose connector