OCCUPANCY 

SENSOR

9OCC-LV — Programming

PAGE 2 OF 3

Remote Control Programming:

The ESL-REM-100 (Sold Separately) can be use to program the 9OCC 
remotely. With a range of 50ft this allows for the flexibility to re-program 
for any reason, at any time. Please see REM-100 spec sheet and/or 
instruction guide for more detailed information.  

DAYLIGHT SENSOR VALUE CONVERSIONS

10  =  0.93 footcandles
30  =  2.97 footcandles
50  =  4.65 footcandles
100  =  9.29 footcandles
300  =  27.87 footcandles
500  =  46.45 footcandles

DEFAULT SETTINGS

Brightness: 100% 

Sensitivity: 100%

Hold Time: 15min

Photocell Disabled

Stand-by Dim: 30% 

Stand-by Time: +∞ No Shut-Off

Button Operation:

 ON/OFF – disables the sensor for a constant on or off position. To enable the sensor, press AUTO.

 AUTO – press to start the sensor with the previously used settings. This must be used to utilize the 

sensor’s capabilities.

 RESET – return to the default settings.

 TEST – select sensitivity thresholds and press and then hold for two seconds. This will disable the 

standby time and daylight sensor in order to check the other settings. To exit, press 

AUTO.

 ARROWS – use to make selections on the LED selectors. Press OK to keep the displayed selections.
 

OK – use to register selections or to clear selections when changing or viewing MODES
 DISPLAY – show the last settings that were uploaded to the sensor or the current selections on the 

remote’s LED indicators. 
 SEND – upload and activate the current selections. The light will turn on and off to confirm. Changing the 

remote settings will not change the sensor settings without pressing 

SEND.

 MODES – save preset parameters by using the MODE buttons. 

TO SET

Press 

MODE button on remote. LED indicators will display the current settings. Use arrows to change 

each parameter. Press 

OK to save the settings to the selected MODE. To activate the settings, aim 

remote at sensor and press 

SEND.

 SMART PHOTOCELL SENSOR – off by default. When enabled, the light will be controlled by the 

photocell only, and the occupancy settings will be disabled. If the ambient light is less than the minimum 

threshold, the light will remain on, 

even if there is no activity. If the ambient light is more than the 

maximum threshold, the light will remain off, 

even if there is activity in the space.

TO SET:

Either press 

DISP or select a MODE to program. Use the ARROWS to select each setting. Set 

STAND-BY TIME to (+∞). Press      . By default, the DAYLIGHT SENSOR will highlight 10 and 300, with 

DIM setting of 10%. Select the minimum threshold (10, 30 or 50) and the maximum threshold (100, 

300 or 500). Change 

DIM level to desired percentage. Press SEND.

LED Indicators:

BRIGHTNESS – select a level to determine the maximum lumen level at full power.
SENSITIVITY – determines how reactive the sensor will be to movement. Range and sensitivity will vary based upon the 

sensor installed.
HOLD TIME – the duration that the light will remain on without detecting movement before dimming or turning off. 
DAYLIGHT SENSOR – uses the photocell to adjust the LED output in conjunction with the ambient light to provide consistent 

lighting regardless of environmental changes. Select the 

EYE       to use a value based on the current ambient light. The 

numbered values correspond to the footcandle conversions listed below. The 

SUN       disables the photocell and will run the 

programmed settings regardless of ambient lighting.
STAND-BY – DIM will determine the maximum lumens to be used when there is no activity detected. A setting of 0% will keep 

the light from dimming. 

TIME will determine how long the light will remain at the dimming level before shutting off completely. 

Setting the time to        will make the light remain on.