19
out at the sensor will increase while the value at the analog output will decrease, ie an
inversely proportional output will be provided.
6.5.4
Analog Output Scale Setting
In the device with the analogue output feature, SCALE mode in this menu must be ON to set
the output signal to the desired scale range. Then S-LO. and S-HI. values can be entered.
6.6
DIGITAL OUTPUT SETTINGS (COMMUNICATION)
WARNING: After changing the UART or CANopen settings, you need to restart the device for
the changes to take effect.
If your device has a USB port, use MyPanelMeter, which you can download from our website
to check your device. Check the user manual of the program.
6.6.1
UART Settings
If you are communicating with your device via RS-485 or RS-232; You can make the
necessary settings here. You can select the communication protocol, baudrate, parity,
address and period information. For the MODBUS Protocol address information, see the
relevant booklet.
6.6.2
CANopen Settings
Here you can set the baud rate, Node ID, Heartbeat, PDO etc. of your device related to
CANopen protocol.
For more information on CANopen, see the EPA 100-CANopen booklet.
6.7
SECURE MENU
6.7.1
Hide Menu (HIDE)
If you don't want to see the operators who will use your device on the menu that you can
hide it by.
All menus are hidden except for Secure.
The Output menu is hidden.
The Calib menu is hidden.
The display menu is hidden.
The Quick Set change menu is hidden. See. 6.3.2
.
.
.
.
.