background image

 

22 

 

PARTS LIST 

 

ITEM No. 

PARTS No. 

DESCRIPTION 

 

DVEL 8 

DVEL 12 

DVEL 20 

 

05070 

05220 

05325 

Front panel 

02380101B 

Mark

 

01196101A 

Nut 

05146 

05262 

05359 

Grill guard 

05046 

Glass frame

 

05090 

Lateral radiation shield 

01212001 

Glass 

01090001 

Gasket 

05175 

05277 

05386 

Combustion chamber 

10 

05075 

05225 

05330 

Back 

11 

01192701 - 01190801B 

Bolt and nut 

12 

01193602 

Nut 

13 

010210C 

01021001C 

01021002C  Vent cap 

14 

05089 

05245 

05256 

Vent-air intake pipe 

15 

05134 

05251 

05338 

Vent pipe 

16 

01212401 

Rod 

17 

-- 

05232 - 01001901A 

Thermostat Sensor bracket 

18 

05078 

Knob support 

19 

-- 

01021307 

Elbow 3/8 NPT x 3/8 NPT 

20 

-- 

01021301 

Elbow 1/4 BSP x 1/4 BSP 

21 

05083 

05228 

05334 

Bracket 

22 

01082001 
01081403 

02230113 
01082102 

01082002 
01081403 

Burner orifice Natural Gas 
Burner orifice L.P.G. 

23 

01141502 

Injector holder 

24 

01143309 

01143309 

01090002 

Pilot gasket 

25 

011433 
011433 

011433 
011433 

01021713D 
01021714D 

Pilot assembly Natural Gas 
Pilot assembly L.P.G. 

26 

05152 

05267 

05385 

Hanging bracket 

27 

01143301C 

01194202 

01194205 

Thermocouple 

28 

02340101 

01143130 

01022111B  Ignitor wire 

29 

05170 

Piezo-ignitor bracket 

30 

01160503 

Spring

 

31 

01001808 

01001807A 

Knob position marking ring 

32 

01160502 

Spring

 

33 

01051402 

Piezo-ignitor 

34 

05113 

05266 

05387 

Outdoor mounting plate 

 
 
 
 
 
 

Summary of Contents for DVEL 12

Page 1: ...SI VOUS SENTEZ UNE ODEUR DE GAZ Ne pas tenter d allumer d appareils Ne touchez aucun interrupteur Ne pas vous servir des t l phones dans le b timent o vous vous trouvez Appelez imm diatement votre fou...

Page 2: ...personal injury or loss of life Refer to this manual Installation and service must be performed by a qualified installer service agency or the gas supplier Do not use this appliance if any part has b...

Page 3: ...tion at elevation above 2000 feet 609 9 m manufactured to specified deration conditions for Canada and the United States NOTE Minimum Gas Inlet Pressure for purpose of input adjustment The efficiency...

Page 4: ...ff valve n Ground joint union n Test gauge connection n Sediment trap n Tee joint n Pipe wrench The installation location shall provide the following a adequate combustion and ventilation air and b ad...

Page 5: ...in a horizontal distance of 2 feet 61 cm from the center line of the terminal D 12 inches 30 cm 1 2 M Clearance to unventilated soffit E Clearance to outside corner F Clearance to inside corner G To e...

Page 6: ...and should stay away to avoid burns or clothing ignition Young children should be carefully supervised when they are in the same room as the appliance Clothing or other flammable material should not...

Page 7: ...HE HANGING BRACKET ON A WOODEN WALL 1 Taking into account the minimum clearances mentioned in figure 4 locate the closest wall stud which will serve to hold the appliance and mark the hole center at a...

Page 8: ...ging bracket and drill the four holes 6 Insert in each hole the anchors provided 7 Place back the hanging bracket and fix it with four screws MOUNTING THE HEATER ON HANGING BRACKET Place the heater on...

Page 9: ...ppareil sont utilis es CAUTION ALL JOINTS MUST BE AIR TIGHT The venting system consists of one injected aluminum cap A one vent pipe B one vent air intake pipe C one rod D one nut E one outdoor mounti...

Page 10: ...nsor from any damage during shipping or while handling it before it is definitely installed the thermostat sensor has not been attached to its final location in the appliance So once the heater is ins...

Page 11: ...uge connections upstream of the gas supply connection to the heater Figure 21 WARNING For L P Gas use PRESSURE REGULATED gas supply Do not directly connect LP supply tank to the pressure regulator on...

Page 12: ...excess of psi 3 5 kPa The appliance must be isolated from the gas supply piping system by closing equipment shutoff valve during any pressure testing of the gas supply piping system at test pressures...

Page 13: ...12 OPERATION CONTINUED Pilot Burner...

Page 14: ...13 POUR COUPER L ADMISION DE GAZ DE L APPAREIL Veilleuse ALLUMAGE...

Page 15: ...from the manufacturing process It is recommended to burn a new wall furnace for at least two 2 hours the first time that it is used CLEANING AND MAINTENANCE WARNING Turn off heater and let cool before...

Page 16: ...attern top view Models DVEL 8 and 12 SECONDARY FLAME PRIMARY FLAME THERMOCOUPLE PILOT FLAME Fig 26 Correct main burner flame pattern top view Model DVEL 20 Cleaning the Main Burner Orifice and Main Bu...

Page 17: ...hen installed 4 Continue holding down control knob Repeat igniting operation until air is removed 5 Pilot is clogged 5 Clean pilot orifice or replace pilot assembly When ignitor button is pressed ther...

Page 18: ...ses 1 Problem will stop after a while of operation 1 Turning control knob to HI position when burner is cold 1 Turn control knob to LO position and let warm up for a minute 2 Air in gas line 2 Operate...

Page 19: ...ements parts must be returned the authorized distributor A UNDER WARRANTY Contact authorized dealers of this product If they are unable to supply original replacement part s call the authorized distri...

Page 20: ...19 Model DVEL 8 19...

Page 21: ...Model DVEL 12 20...

Page 22: ...Model DVEL 20 21...

Page 23: ...Sensor bracket 18 05078 Knob support 19 01021307 Elbow 3 8 NPT x 3 8 NPT 20 01021301 Elbow 1 4 BSP x 1 4 BSP 21 05083 05228 05334 Bracket 22 01082001 01081403 02230113 01082102 01082002 01081403 Burne...

Page 24: ...5 05137 05257 05376 Top Radiation Shield 46 01160902 Nipple 1 4 BSP x 3 8 NPT 47 02830110B 02830138B 02830140 Burner tubing 48 02830109B 02830137B 02830141B Pilot tubing 49 011935A Nut 50 01024001 028...

Page 25: ...24 ESKABE S A Ruta 2 No 323 7600 Mar del Plata Pcia de Buenos Aires Argentina Authorized Distributor in USA and Canada Cod Mat XXXX XX XXX...

Reviews: