ESI Unik Pus User Manual Download Page 5

ESI 

uniK plus

 

 

5

2.1 Unpacking / Handling 

To remove the monitor from the carton its best to turn the package carefully upside down on the 
floor or on a table and then lift the carton vertically up slowly to leave the monitor resting in the 
packaging foam. Make sure that you don’t grab the speaker driver units on the front to avoid 
damage. Now check the monitor for signs of damage that might have occurred in shipping. In the 
unlikely event of this, please contact the reseller of the product immediately. Be careful when you 
remove the packaging foam. Please keep all packing materials. 

You will when unpacking that the uniK plus is shipped with a power cable, the ESI Bass Port 
Plug

TM

 made from a special acoustic material and with 4 rubber feet that can be installed and 

removed when required (more on that below in section 3.7 and 3.8). 

2.2 Connection 

High quality XLR balanced, TRS balanced or TS unbalanced audio cables are recommended for 
input connection. The monitor typically connects to the line level output of a mixing console or to a 
computer audio card. Make sure the power of the monitor is switched off before you connect any 
audio cables. 

XLR balanced connection 

Connect male side of XLR balanced cable to the balanced XLR input of uniK plus. Make sure the 
power cable is connected as well. Setup all speakers (i.e. left / right channels) with the same type of 
cable. 

TRS balanced or TS unbalanced connection 

Connect male side of TRS balanced or TS unbalanced cable to the input jack of uniK plus. Make 
sure the power cable is connected as well. Setup all speakers (i.e. left / right channels) with the 
same type of cable. 

3. Placement / Positioning / Setup 

The placement of monitoring speakers is very critical and can compromise their performance. This 
is a general rule for every loudspeaker. To monitor with uniK plus utilizing their maximum 
capabilities, an appropriate listening environment and a correct placement are important. 

Typically you would be using 2 units of uniK plus as one stereo pair – or more in surround setups 
(i.e. in a 5.1 setup you would use 5 units of uniK plus together with a subwoofer). 

uniK plus can also be tilted up and down using rubber feet (3.8) and depending on the room 
environment you have the option to use them as a closed speaker system or open with bass reflex 
port utilizing our ESI Bass Port Plug

TM

 (3.7). 

Summary of Contents for Unik Pus

Page 1: ...Professional Active Reference 5 and 8 Studio Monitor User s Guide...

Page 2: ...ESI Copyright 2014 Revision 1 September 2014 www esi audio com...

Page 3: ...2 0 Positioning 6 3 2 Stereo with Subwoofer 2 1 Positioning 6 3 3 Surround 5 1 Positioning 7 3 4 Surround 7 1 Positioning 7 3 5 Orientation 8 3 6 Additional Comments 8 3 7 ESI Bass Port PlugTM for ven...

Page 4: ...igh resolution high and low switches add additional control and of course there is the option to utilize our ESI Bass Port PlugTM for further room adjustment i e to control the low frequencies in smal...

Page 5: ...sure the power of the monitor is switched off before you connect any audio cables XLR balanced connection Connect male side of XLR balanced cable to the balanced XLR input of uniK plus Make sure the p...

Page 6: ...owing diagram to understand how to position your monitors Each distance x should be identical 3 2 Stereo with Subwoofer 2 1 Positioning In a stereo setup with an added subwoofer the subwoofer speaker...

Page 7: ...should be positioned around 110 from the center speaker all with the same distance x 3 4 Surround 7 1 Positioning In a 7 1 surround set the center speaker should also ideally be placed on top of the s...

Page 8: ...a vent port that is conveniently placed on the backside of the unit making sure that air does not get blown into your face when you listen in a near field situation and to make sure that parasitic fre...

Page 9: ...reduce unwanted vibrations depending on where exactly the speaker is placed They can individually be adjusted by turning them in and out or they can be removed altogether if you prefer not to use them...

Page 10: ...near field operation ESI Bass Port PlugTM removed Ground lift switch Standby function can be turned on and off Indicator multi color LED on front panel power on orange standby red over load red flashi...

Page 11: ...ight separately Working Voltage AC100 240V 50 60Hz Dimensions W x H x D 252 x 352 x 319mm Weight 8 1 kg 4 3 Rear Panel The following picture shows the rear panel of uniK 05 The functions of uniK 08 ar...

Page 12: ...to adjust the speaker properly to the input level from the sound source Make sure to setup all speakers accordingly When set to 0 middle position the input level is set to the recommended calibrated l...

Page 13: ...OFF This allows you in some situation to reduce or remove unwanted hum noise when there are issues with grounding of your audio signals in your studio setup 9 standby switch you can turn the standby...

Page 14: ...marks of their respective companies Correspondence For technical support inquiries contact your nearest dealer local distributor or ESI support online at www esi audio com Disclaimer All features and...