background image

 

September 2013, rev A 

 

 

 

 

© 2013 Electronic Solutions, Inc. 

 

 

 

 

Page 1 of 4 

 

M50Q 230VAC series, v4.7 

Motor 

Quick Setup

 

Electronic Solutions, Inc. 

1355 Horizon Avenue 

Lafayette, CO 80026 U.S.A. 

www.elec-solutions.com 

Tel: (303) 469-9322

 

 

 
 
 
 

Introduction 

This document explains how to set motor limits (end positions) and how to connect the low voltage data cables 
to an M50Q series motor. Refer to the 

M50Q 230VAC Specifications

 document for technical details. 

Products 

M50Q 230VAC 50Hz series motors 

—M50Q 626B, M50Q 1530B 

NOTE

:  M50Q 

part numbers ending with “A” are 120VAC and those ending with “B” are 230VAC. 

Before You Start 

  On power-up: LEDs will blink 

GREEN

 

YELLOW

 

  CW is clockwise rotation looking at the motor from the head end, CCW is counterclockwise. 

  Be sure the motor is connected to continuous AC power. 

  An M50Q series motor ships from the factory with a randomized RQ address between C00 and ZZZ and no 

limits set. 

  The M50Q series motor has a 3-conductor, keyed AC power connection in the motor head for connecting the 

included AC power cord, PC M40/50 UNIV. 

  The M50Q series motor has a 5-conductor, keyed low voltage, data connection (RQ Bus and RP Bus) for 

use with the CBL 6 FT QE QM, CBL 1 FT QE QM, or RE 1 FT QM, each sold separately. This cable must be 
connected after the AC power connection is in place and AC power is applied. 

  The M50Q series motor has a 3-conductor, keyed low voltage, manual input (dry contact) connection for use 

with CBL 6 FT DM, sold separately. This cable must be connected after the AC power connection is in place 
and AC power is applied. 

  The M50Q series motor has three clear buttons with internal LEDs: 

o

 

Button 1, 

RED

 LED button, with one groove, operates the motor counterclockwise [CCW]. 

o

 

Button 2, 

GREEN

 LED button, with two grooves, operates the motor clockwise [CW]. 

o

 

Center Button, 

YELLOW

 LED button with no groove, used to set and clear motor options. 

  If any button is pressed while the motor is moving, the motor will stop. 

  Use an SP1E3Q when connecting more than two RQ-enabled motors (M40Q or M50Q). 

  Refer to the 

M40Q and M50Q Typical Wiring Diagram

 on page 4 for an example of wiring. 

 
 

 

Reviews: