IVX 128 Plus upgrade guide 

 

Procedure 2: Using Procomm Plus to perform the upgrade 

1. 

Insert the IVX 128 Upgrade CD-ROM into your PC’s CD-ROM drive.  

2. 

Use Procomm Plus to connect to the system using baud rate of 38,400 bps with no parity, 8 data 
bits, 1 stop bit and software flow control. 

3. 

Press the 

Enter

 key. A 

Password

 prompt will be displayed. 

4. 

Type the installer password and press 

Enter

. The main menu will now appear:  

 

/***********************************************\ 
|             REMOTE OPERATIONS                 | 
| --------------------------------------------- | 
| 1 - Receive Software or Prompts (Disconnect)  | 
| 2 - Receive software/Prompts (Stay connected) | 
| 4 - Display installed program versions        | 
| 8 - Disconnect                                | 
| 9 - Exit this command                         | 
\***********************************************/ 

Enter your choice from the menu: 

 

5. 

Press 

4

 and 

Enter

. The contents of each slot will be displayed. Note which slot (2 or 3) is empty or, if 

both slots are occupied, which has the oldest (lowest number) version. 

6. 

Press 

2

 and 

Enter

. A new menu will appear:  

 

/*********************************************\ 
|        RECEIVE SOFTWARE & PROMPTS           | 
| ------------------------------------------- | 
| 2 - Store Program in Slot 2                 | 
| 3 - Store Program in Slot 3                 | 
| 4 - Standard Prompts                        | 
| 8 - Disconnect                              | 
| 9 - Exit this command                       | 
| 0 - Return or press the ENTER key           | 
\*********************************************/ 

Enter your choice from the menu: 

 

7. 

Enter the number of the slot you noted in step 5 and press 

Enter

. A prompt to 

Enter Program 

Release Number

 will appear: 

/*****************************************************************\ 
| Enter Program Release Number, a blank space, and Execution Code | 
| Execution Codes: 1=At first idle                                | 
|                  2=At midnight                                  | 
|                  3=On the first power cycle                     | 
|    (Example: 2.7.1 1)                                           | 
| e to exit this command OR d d to disconnect                     | 
\*****************************************************************/ 

Enter: 

8. 

Type in 1.10.8 3 (i.e., the conversion program version, followed by a space, followed by execution 
code 3)and press 

Enter

9. 

Confirm your entry by typing 

Y

 and pressing 

Enter

10. 

A message will appear: “System is ready to receive program into Slot x . . .” 

11. 

From the Procomm Plus menu, select 

Data

, then 

Send File

. The 

Send File using

 window will appear. 

Summary of Contents for IVX 128

Page 1: ...e installation Procedure 1 Using Esi Access to perform the upgrade Notes The following instructions assume that you are familiar with Microsoft Windows and Esi Access If you need more information on E...

Page 2: ...send the IVX 128 conversion program 13 When the software load has completed power down the cabinet and power it up again Wait for the phone displays to come back on about 4 6 minutes before continuing...

Page 3: ...pied which has the oldest lowest number version 6 Press 2 and Enter A new menu will appear RECEIVE SOFTWARE PROMPTS 2 Store Program in Slot 2 3 Store Program in Slot 3 4 Standard Prompts 8 Disconnect...

Page 4: ...ple If the second bin file is named 128_2117 bin enter 2 11 7 followed by a space and the numeral 3 and then press Enter 22 Confirm your entry by typing Y and pressing Enter 23 A message will appear S...

Page 5: ...cation You ll now need to identify the main board s assembly number in order to install the correct expansion memory SIMM 4 MB or 8 MB 1 Power down the cabinet and remove the top cover and port card 2...

Page 6: ...inet Power up the cabinet 3 The system will initialize 4 Proceed to Restoration of programming page 7 Main board assembly 5010 0544 1 Remove the existing SIMM from the U13 connector Note Be sure to re...

Page 7: ...2 Connect to the system using Esi Access 3 Clickon Restore and select the date and time of the backup to restore then clickon OK The system s configuration will be restored from the backup file 4 Onc...

Reviews: