If there are 4 flanges, 

push down the top and 

bottom flanges to leave 

just 1 on either side. 

Use a 35mm back box 

with 2 screw flanges.

  2. 

18

7.2.2 Installing the Programmable Room Thermostat

  1.  Use a flat headed screwdriver to press the fastener at the top of 

the unit, then gently loosen from the unit, unhooking from top to 

bottom.

Fix the 35mm back box, terminals at the top, onto a 2 flange 

metal back box with 2 BM3.5x23 screws.  If installing on a 4 

flange metal back box, simply push down the flanges on the top 

and bottom to leave the flanges on the left and right hand side.

off means the thermostat cannot find any router to 

connect to
flashing means the thermostat is connected to the router 

but cannot connect to the server
constantly on means the thermostat is successfully 

connected to the router and server

Summary of Contents for ESRTP5WIFI

Page 1: ...ESRTP5WIFI 5 Series WiFi Programmable Room Thermostat with TPI Delayed Start User and Installation Instructions...

Page 2: ......

Page 3: ...iday Mode HOLI 6 3 4 Boost bOSt 7 4 Main Menu 4 1 Copy Function CoPy 8 4 2 Backlight On Off LIGH 8 4 3 Resetting the Unit rESE 9 5 Programme Settings ProG 5 1 Pre Set Temperatures 10 5 1 1 5 2 Day 5 1...

Page 4: ...ructions 16 7 1 3 Warning Notices 16 7 1 4 Maintenance 17 7 2 1 Fitting the Programmable Room Thermostat 17 7 2 2 Installing the Programmable Room Thermostat 18 7 2 3 Wiring Diagram 19 8 Technical Set...

Page 5: ...atically update the time and date when a WiFi connection is established To manually set use the dial to adjust the hour then press Repeat this to set the minute day date and month date Next set the ye...

Page 6: ...on mode Off Frost protection mode Manual operation mode Flame symbol when system calling for heat Cancels and returns to the previous menu Either confirms and saves the setting or moves you to next op...

Page 7: ...1 2 Quick Command Guide 2...

Page 8: ...nd hold until the display shows tINE then press 2 Turn the dial to adjust the hour then press 3 Turn the dial to adjust the minute then press 4 Turn the dial to adjust to the current day then press 5...

Page 9: ...ture range 5o C 35o C Default 21o C N B The temporary set temperature will not replace the original program event s set temperature When the program event ends it will return to the default heating pr...

Page 10: ...e dial to desired temperature then press to confirm and automatically return to the homescreen Press in the homescreen to exit All Day mode and return to Auto mode 3 1 2 MAN Permanent manual override...

Page 11: ...splay will alternate between HOLI Days Holiday HOLI Current room temperature To adjust the settings in Holiday mode turn the dial to adjust holiday days press to confirm Then turn the dial to adjust s...

Page 12: ...urrent room temperature To adjust the settings in Boost turn the dial to enter the Boost setting and bOSt will display Use the dial to adjust the number of hours for the boost to run press to confirm...

Page 13: ...7 Press and hold until the display shows tINE Turn the dial until display shows CoPy then press Use the dial to select the day to be copied then press to confirm Use the dial to select the day to be...

Page 14: ...If set permanently ON the light will automatically switch to a lower light setting and be dimmer 4 3 Resetting the Unit rESE Resetting the unit will return the thermostat to default setting The time d...

Page 15: ...re settings 10 5 Programme Settings ProG 5 1 Factory Pre Set Programme This unit has been designed to be a simple to use thermostat requiring minimal user intervention with a pre programmed heating pr...

Page 16: ...ally return to homescreen 11 Choose 5 2 day operation see 5 2 for details Then press Turn the dial to select the days to programme either 1 5 for weekdays or 6 7 for weekends then press Turn the dial...

Page 17: ...hen press Turn the dial to choose the program P1 P6 Then press to enter time setting Turn the dial to adjust the time 10 minutes increments Then press to enter temperature setting Turn the dial to adj...

Page 18: ...new device Enter the individual thermostat WiFi code this will be found on the thermostat Then tap next Select your router and enter your router password Then tap next and the APP will search for the...

Page 19: ...Installa on Instruc ons...

Page 20: ...1o C Program event start time 00 00 24 00 See 5 1 for details Program event set temperature 5o C 35o C See 5 1 for details Program operation mode 5 2 day 7 day 24hr Default 5 2 day Number of programs...

Page 21: ...s Power supply 230VAC 3 1 A SPDT Temperature Sensor Type 1o C at 20o C Total Switch Rating 3 1 A 230 VAC Contact Type SPDT Volt Free changeover contacts Plastic Thermoplastic flame retardant Protectio...

Page 22: ...ired as the product is double insulated but ensure continuity of earth throughout the system 7 1 2 General Safety Instructions This product complies with the essential requirements of the follow ing E...

Page 23: ...to locate the Programmable Room Thermostat is about 1 5m above floor level in a location where the thermostat is accessible reasonably lit and free from extremes of temperature and draughts Do not po...

Page 24: ...t 1 Use a flat headed screwdriver to press the fastener at the top of the unit then gently loosen from the unit unhooking from top to bottom Fix the 35mm back box terminals at the top onto a 2 flange...

Page 25: ...al 4 NC Normally Closed 5 NO Normally Open 19 Route the wires through the back of the wall plate Fit the wires to the wall plate in accordance with the relevant diagram and in accordance with I E E re...

Page 26: ...8 Technical Settings 8 1 Quick Command Guide 20...

Page 27: ...nt room tempera ture tPI TPI Default is OFF Use the dial to choose between OFF function disabled 3CYC each hour has 3 heating cycles recommended for oil boilers or 6CYC each hour has 6 heating cycles...

Page 28: ...due by displaying SER in the screen 30 days before due date The operation of the system will not be affected 2 Reminds the user when the annual service is due by displaying SER in the screen 30 days b...

Page 29: ...9 1 and use the dial to select CODE then press Use the dial to set the first digit of the new password then press to move to the next digit Repeat this for all 4 digits On the last digit press to con...

Page 30: ...ntinuous product improvement we reserve the right to alter designs specifications and materials without prior notice and cannot accept liability for errors WARNING Interference with sealed parts rende...

Page 31: ......

Page 32: ...Version 6 11 1 ESi Controls Limited sales esicontrols co uk www esicontrols co uk...