19
1. To engage the manual override, press the
MANUAL
button on the receiver, which will then light up with a
green background. This shows that the manual override
is active.
2. Use the
M/A
button to manually override the status of
the receiver. If ON, the heating will turn OFF (M/A red
light goes off). If OFF, the heating will turn ON (M/A red
light comes on).
N.B.
It is important to remember that the automatic control
of the receiver is now off and the receiver will only
respond to manual operations.
3. To return to Auto mode, press the
MANUAL
button on
the receiver and the green light will turn off. The receiver
should now be back in Auto mode, recieving commands
from the thermostat.
N.B.
If the receiver cannot receive a signal for 30 minutes,
both the red and green light will flash and the unit will
need to be reconfigured.
WARNING: Interference with sealed parts renders the
guarantee void.
In the interests of continuous product improvement we reserve
the right to alter designs, specifications and materials without
prior notice and cannot accept liability for errors.