esera 1-Wire Multisensor Pro II User Manual Download Page 6

All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of 
ESERA GmbH. Errors and technical modification subject to change. 



ESERA GmbH 2021 

www.esera.de 

11165 V1.0 R1.1 Manual 

Page 6 of 8 

 
 
 
 
 
 

15 

Terminal assignment 

The 1-Wire Multisensor Pro II is connected via Push-In 
 terminals. 
The connection terminal is intended for solid cables  
with a cross-section of 0.2 to 2.5qmm or fine-stranded cables  
with a cross-section of 0.2 to 1.5qmm. For connection we  
recommend slotted screwdriver size of 2,5x75. 
The pin assignment is printed on the printed circuit board.  
It is necessary to pay attention to the correct polarity when  
connecting. 
The Multisensor is to be connected with three cables (Ground,  
1-Wire Data and 5V). The parasitic mode is not supported. 

 

 
 

 

16 

Assembly 

The installation location must be protected from direct 
moisture (e.g. dripping water) and drafts. The device may 
only be used in dry indoor rooms and in protected outdoor 
areas.  
A location free of drafts must be selected for installation. 
The device is intended for installation as a stationary 
device. The 1-Wire Multisensor can be ideally mounted on 
a flush-mounted box thanks to clever housing cutouts. 

 
 

 

17 

1-Wire Network Cabling 

The special feature of the 1-Wire system is the "BUS technology". All devices (sensors and actuators) are 
operated in parallel on a three-wire line, which is used for both power supply and data communication. The 1-
Wire bus system joins the list of other successful bus systems such as CAN or Modbus RTU. All of the installation 
principles recommended for these are also applicable and appropriate to 1-Wire.  
The maximum size of a 1-Wire Network is determined by various factors. These are mainly:  

Total cable length and cable type 

Number of 1-Wire devices 

Type of cable installation (topology) 

Number and design of cable connectors (unnecessary connection transitions should be avoided) 

All factors in total are summarised and referred to as 1-Wire Bus load. Each increase of a factor increases the 
total 1-Wire Bus load for the 1-Wire controller and thus reduces the maximum network size.  
 

Note 

The module may only be operated at the voltages and under the ambient conditions intended for it. The 
operating position of the device is arbitrary. 
The modules may only be commissioned by a qualified electrician. 
 
For further information on the operating conditions, see the following instructions under 
"Operating conditions". 
 

Note 

The sensor module and the carrier frame are 
connected with a narrow ribbon cable. Avoid 
mechanically stressing the red connector plugs or 
pulling on the ribbon cable. 
Overloading may cause irreparable damage. 
 

Summary of Contents for 1-Wire Multisensor Pro II

Page 1: ...tial applications smart building smart home schools public buildings and companies High accuracy Sensors with 12bit resolution Air Quality Sensor VOC with short warm up time and fine resolution at low power consumption Universal in wall mounting Shapely and high quality sensor housing Simple 5VDC power supply Application Multisensor for heating control single room control Air Humidity Sensor for m...

Page 2: ...ng a ventilation system In combination with 1 Wire ESERA Switching modules binary outputs a very effective and energy saving heating control single room control is possible The 1 Wire Multisensor Pro II is intended for use in normal living spaces For outdoor use and in damp rooms such as sauna steam bath or winter garden a suitable sensor is available via the ESERA website The 1 Wire Multisensor P...

Page 3: ... of time and therefore money when searching for a 1 Wire device o Classes Assignment ESERA 1 Wire devices are assigned to OWD classes with the same properties This assignment enables fully automatic visualization and data evaluation in control systems A class list is available from ESERA For further information about the ESERA Auto E Connect system please refer to the ESERA website and the ESERA C...

Page 4: ...50090 2 2 EN 61000 4 2 ESD EN 61000 4 3 HF EN 61000 4 4 Burst EN 61000 4 5 Surge EN 61000 6 1 interference immunity EN 61000 6 3 interference radiation RoHS REACH 7 Software control The 1 Wire Multisensor Pro II is read out via 1 Wire command for DS2438 devices The Multisensor is supported in many controllers such as ESERA Station Loxone IP Symcon OWFS FHEM Linux or microcontroller applications Fo...

Page 5: ...ebsite at Kompatible Steuerungen Zentralen IP Symcon Integration https www esera de kompatible steuerungen zentralen ip symcon integration For the conventional connection via 1 Wire Bus Coupler the sensor values have to be calculated according to the given formulas 10 Integration in Loxone Via the shop we provide a sample project for reading in the 1 Wire Multisensor via 1 Wire controller 1 1 Wire...

Page 6: ... Wire Network Cabling The special feature of the 1 Wire system is the BUS technology All devices sensors and actuators are operated in parallel on a three wire line which is used for both power supply and data communication The 1 Wire bus system joins the list of other successful bus systems such as CAN or Modbus RTU All of the installation principles recommended for these are also applicable and ...

Page 7: ...collection local collection points for electronic waste 20 Safety instructions When handling products that come into contact with electrical voltage the applicable VDE regulations must be observed in particular VDE 0100 VDE 0550 0551 VDE 0700 VDE 0711 and VDE 0860 All final or wiring work must be carried out with the power turned off Before opening the device always unplug or make sure that the un...

Page 8: ... or gross negligence Claims made under the Product Liability Act are not affected If defects occur for which ESERA GmbH is responsible and in the case of replacement goods the replacement is faulty the buyer has the right to have the original purchase price refunded or a reduction of the purchase price ESERA GmbH accepts liability neither for the constant and uninterrupted availability of the ESER...

Reviews: