esera automation Windsensor Pro 200 User Manual Download Page 3

 

Art. No. 20020  

 

 

 

All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of 
ESERA-Automation or E-Service GmbH. Errors and technical modification subject to change. 

 ESERA-Automation, E-Service GmbH 2019 

www.esera.de 

20020 V1.0 R1.0  Manual 

Page 3 of 4 

Connection example 1-Wire System and 1-Wire Controller / 1-Wire Gateway 

 

 

Software / Evaluation 

The wind sensor delivers 4 pulses per revolution. To calculate the wind speed, the pulses are usually counted for 
a period of e.g. 1 minute, in our example by the ESERA 1-Wire S0 counter 11211 and then divided by the factor 4 
(4 pulses = 1m/s). The result is the wind speed in m/s. 
To get to Km/h, the value m/s is multiplied by 3600 and then divided by 1000.  
 
Formula: 
Counter reading new - Counter reading old = Delta 
 
Wind speed: m/s = delta / factor (4), Km/h = m/s x 3600 / 1000 
 

Operating conditions 

The sensor may only be operated at the specified voltages and ambient conditions. The operating position of the 
device is vertical. The sensor is designed for continuous outdoor operation. 
Due to the heating inside the sensor, the housing heats up. Do not operate the sensor in an 
environment in which flammable gases, vapors or dusts are present or may be present. 
 

 

Disposal instructions   

Do not dispose of the device in domestic waste! Electronic devices are to be disposed of 
according to the Directive on waste electrical and electronic equipment (WEEE) on local 
authorities and collection points for waste electronic equipment!

  

 

10 

Safety instructions 

When using products that come into contact with electrical voltage, the valid VDE regulations must be observed, especially 
VDE 0100, VDE 0550/0551, VDE 0700, VDE 0711 and VDE 0860 

 

All final or wiring work must be carried out with the power turned off. 

 

Before opening the device, always unplug or make sure that the unit is disconnected from the mains. 

 

Components, modules or devices may only be put into service if they are mounted in a contact proof housing. 
During installation they must not have power applied. 

 

Tools may only be used on devices, components or assemblies when it is certain that the devices are 
disconnected from the power supply and electrical charges stored in the components inside the device have been 
discharged. 

 

Live cables or wires to which the device or an assembly is connected, must always be tested for insulation faults 
or breaks. 

 

If an error is detected in the supply line, the device must be immediately taken out of operation until the faulty 
cable has been replaced. 

Summary of Contents for Windsensor Pro 200

Page 1: ...formation for retracting an awning or raising roller shutters or blinds slats can be provided via the system control The wind sensor Pro 200 is an optimal environmental sensor for recording the wind speed for weather recording in weather stations All metal parts of the Pro 200 wind sensor such as bearings and screws are made of weather resistant stainless steel and are durable over a long period o...

Page 2: ...nnecting cables ca 3m cable 4 strands Evaluation Pulse output for 1 Wire S0 counter 11211 Dimensions ca 210 mm x 80mm height x width Windmill Ø 160 mm Accessories Mast bracket wall bracket mast for flat roof Scope of delivery Windsensor without mounting bracket 3 Ambient conditions Protection system IP65 Protection class III Temperature Operation 40 C to 125 C 4 Conformity EN 50090 2 2 EN 61000 4 ...

Page 3: ...or in an environment in which flammable gases vapors or dusts are present or may be present 9 Disposal instructions Do not dispose of the device in domestic waste Electronic devices are to be disposed of according to the Directive on waste electrical and electronic equipment WEEE on local authorities and collection points for waste electronic equipment 10 Safety instructions When using products th...

Page 4: ... 11 Warranty ESERA Automation E SERVICE GmbH guarantees that the goods sold at the time of transfer of risk to be free from material and workmanship defects and have the contractually assured characteristics The statutory warranty period of two years begins from date of invoice The warranty does not extend to the normal operational wear and normal wear and tear Customer claims for damages for exam...