esera automation 11320 User Manual Download Page 1

 

Art. No. 11320  

 

All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of 
ESERA-Automation or E-Service GmbH. Errors and technical modification subject to change. 



ESERA-Automation, E-Service GmbH 2020 

www.esera.de 

11320 V1.0 R1.0 Manual 

Page 1 of 8 

 
 

User guide 

1-Wire Controller 1 RS232 

 

 

  1-Wire controller for autonomous communication and updating of the 

1-Wire network.  

  Fast readout of all 1-Wire devices in  

1-2 seconds cycle  

  Cyclic output of the prepared 1-Wire data in plain text 

  Operation without additional driver 

  Data logging when communication to the control system / host system 

is interrupted (optional) 

  Power supply for 1-Wire network 

  Designed for small to large 1-Wire networks 

  DIN rail housing for control cabinet installation  

  Wide supply voltage range 

  Management of all ESERA automation and many standard  

1-Wire modules 

 

   
 

 

Introduction 

Before you start to install the 1-Wire Controller 1 and put the device into operation, please read through this 
operating manual at your leisure until the end, especially the section of the safety instructions.  
All settings and configurations of the 1-Wire Controller are carried out with the "Config Tool 3". This software 
can be found on the ESERA website. Please refer to the "Config Tool 3" manual, which can be found within 
the Config Tool software under the "HELP/SUPPORT" tab. 
 

Product description

   

 

 

  

autonomous administration 

The 1-Wire Controller 1 is designed for the autonomous management of a 1-Wire network. You no longer 
need to worry about 1-Wire commands or formulas for evaluating sensor data. The controller independently 
scans the 1-Wire network for devices (sensors and actuators) and, depending on the device found, outputs 
the corresponding data in plain text, fully converted. 
 

Formatted data output 

  

The 1-Wire Controller 1 provides the sensor and actuator data ready prepared, e.g. for temperature sensors  
in C° cyclically out. Only one division by 100 is necessary. 
In addition, the article number for ESERA modules can be entered, the calculation and output is adapted to 
the function of the module. 

 
Designed for all 1-Wire Networks 

The 1-Wire interface of the 1-Wire Controller 1 is specially designed for small to very large  
1-Wire networks with long cable distances can be operated safely. Mixed 1-Wire sensors can be operated 
simultaneously in parasitic or normal mode. 
The currently strongest 1-Wire interface for maximum data security, even for complex network structures, 
has been installed.   

 
System time / real time clock 

You do not have a real-time clock with battery buffering in your system? No problem, the 1-Wire Controller 1 
gladly provides the time with date. The real-time clock (RTC) is supplied by a maintenance-free gold cap 
(super capacitor) for approx. 2 days in case of power failure. 
What is a Goldcap (super capacitor)? You can find an explanation here:  
https://de.wikipedia.org/wiki/Superkondensator 

Summary of Contents for 11320

Page 1: ...ware under the HELP SUPPORT tab 2 Product description autonomous administration The 1 Wire Controller 1 is designed for the autonomous management of a 1 Wire network You no longer need to worry about 1 Wire commands or formulas for evaluating sensor data The controller independently scans the 1 Wire network for devices sensors and actuators and depending on the device found outputs the correspondi...

Page 2: ...ply failure In case of a longer failure the RTC must be reset The Goldcap is charged after approx 2 hours firmware update configuration ESERA Config Tool III 1 Wire interface 1 Wire Bus 5V ground and data protection circuits ESD and reverse polarity protection connection Screw terminals up to 2 5qmm cable cross section output voltage 5V 10 max 200mA overload and short circuit proof isolation Galva...

Page 3: ...e GmbH Errors and technical modification subject to change ESERA Automation E Service GmbH 2020 www esera de 11320 V1 0 R1 0 Manual Page 3 of 8 7 Connection diagram Module top side 1 Wire Bus 7 ground 1 Wire 8 1 Wire Data 9 5V output Module bottom side Power supply 10 30VDC 1 Minus supply voltage 2 Plus supply voltage Note 11 Reset Button 8 Connection example 1 Wire Multisensor ...

Page 4: ...ide complete or in part requires the written consent of ESERA Automation or E Service GmbH Errors and technical modification subject to change ESERA Automation E Service GmbH 2020 www esera de 11320 V1 0 R1 0 Manual Page 4 of 8 Connection example 1 Wire Hub III Sensors und Actuators ...

Page 5: ... program can be found in the download area of the ESERA online shop 10 Configuration and Communication with 1 Wire Controller 1 The 1 Wire Controller 1 has extensive configuration and formatting options that can be read and operated with the ESERA Config Tool 3 Since the communication between the 1 wire controller 1 and the Config tool 3 takes place via the open ESERA ASCII text protocol you can a...

Page 6: ...lers Central Units Loxone Integration https www esera de kompatible steuerungen zentralen loxone integration demo 1 wire controller 1 loxone integration 14 Example of integration in FHEM For integration into the open source automation software FHEM we provide a software module for easy integration of the 1 Wire controller This provides you with a very powerful 1 Wire interface in FHEM Details can ...

Page 7: ...se of doubt consultation with experts or the manufacturer of the components used is absolutely necessary For operational and connection errors outside of our control we assume no liability of any kind for any resulting damage Kits should be returned without their housing when not functional with an exact error description and the accompanying instructions Without an error description it is not pos...

Page 8: ... designations of their respective owners and are hereby expressly recognized as such by us The mention of these designations logos names and trademarks is made for identification purposes only and does not represent a claim of any kind on the part of ESERA Automation E Service GmbH on these designations logos names and trademarks Moreover from their appearance on ESERA Automation webpages it canno...

Reviews: