Connection example with iButton reader 

 

 

12 

Software  

Data interface ESERA ASCII text 
protocol 

You configure the Ethernet interface 
with the help of the Windows ESERA 
program "Config Tool 3". This 
program can be found in the 
download area of the ESERA online 
shop 

 

13 

Configuration and 
Communication with  
1-Wire Controller 1 

The 1-Wire Controller 1 has 
extensive configuration and 
formatting options that can be read 
and operated with the ESERA 
"Config-Tool 3". 
Since the communication between 
the 1-Wire controller 1 and the 
Config-Tool 3 takes place via the 
open ESERA ASCII text protocol, you can also use any terminal program to  
(e.g. Hercules or Putty) exchange data with the 1-Wire Controller 1 via UDP / TCPIP and carry out the 
configuration  
For details on the communication commands, refer to the document "Programming Manual", which can be 
found in the download area of the ESERA online shop and within Config-Tool 3. 
 
 
 

Summary of Contents for 11319

Page 1: ...ns carefully to the end especially the section referring to the safety notes 2 Product description Independent management The 1 Wire Controller is designed for the independent management of a 1 Wire network You no longer have to worry about the 1 Wire commands or formulas in order to evaluate sensor data The controller independently scans the 1 Wire network for components sensors and actuators and...

Page 2: ...ndustrial applications and enables significant added value beyond the sensor and chip data The Auto E Connect function automatically recognizes ESERA chips sensors and actuators starts suitable libraries and outputs fully formatted data The Auto E Connect functionality will be available from mid 2020 via 1 Wire Controllers 1 Wire Gateways and 1 Wire ECO from ESERA available Further information on ...

Page 3: ...ing the function of the displays Display Designation Function LED Green PWR Display for supply voltage LED Green DATA after switching on the device the LED flashes 3 times flashes during 1 Wire activity View when sending data via the data interface flashes very quickly if AL Receive has been activated and the CAL messages of the control system are missing LED Green Data interface Network Link LED ...

Page 4: ...cation of this user guide complete or in part requires the written consent of ESERA GmbH Errors and technical modification subject to change ESERA GmbH ESERA Automation 2020 www esera de 11319 V3 0 R1 0 Manual Page 4 of 9 9 Connection example 1 Wire Multisensor ...

Page 5: ...ion of this user guide complete or in part requires the written consent of ESERA GmbH Errors and technical modification subject to change ESERA GmbH ESERA Automation 2020 www esera de 11319 V3 0 R1 0 Manual Page 5 of 9 10 Connection example 1 Wire Hub III Sensors and Actuators ...

Page 6: ...nd in the download area of the ESERA online shop 13 Configuration and Communication with 1 Wire Controller 1 The 1 Wire Controller 1 has extensive configuration and formatting options that can be read and operated with the ESERA Config Tool 3 Since the communication between the 1 Wire controller 1 and the Config Tool 3 takes place via the open ESERA ASCII text protocol you can also use any termina...

Page 7: ...Example for the integration into IP Symcon On our website we provide ESERA IP Symcon software modules for easy integration of the 1 Wire Controller into IP Symcon This provides you with seamless integration into the software Details can be found on the ESERA website under Compatible controllers central units IP Symcon integration https www esera de kompatible steuerungen zentralen ip symcon integr...

Page 8: ...of housing During installation they must not have power applied Tools may only be used on devices components or assemblies when it is certain that the devices are disconnected from the power supply and electrical charges stored in the components inside the device have been discharged Live cables or wires to which the device or an assembly is connected must always be tested for insulation faults or...

Page 9: ...ESERA GmbH accepts liability neither for the constant and uninterrupted availability of the ESERA GmbH for technical or electronic errors in the online offer We develop our products further and we reserve the right to make changes and improvements to any of the products described in this documentation without prior notice If you need documentation or information about older product versions contac...

Reviews: