16 

Disposal instructions   

Do not dispose of the device in household waste! Electronic instruments are to be disposed 
of according to the Directive on Waste Electrical and Electronic Equipment on local 
Collection points for electronic waste must be disposed of! 

 

17 

Safety instructions 

When using products that come into contact with electrical voltage, the valid VDE regulations must be 
observed, especially VDE 0100, VDE 0550/0551, VDE 0700, VDE 0711 and VDE 0860 

 

All final or wiring work must be carried out with the power turned off. 

 

Before opening the device, always unplug or make sure that the unit is disconnected from the mains. 

 

Components, modules or devices may only be put into service if they are mounted in a contact proof housing. During 
installation they must not have power applied. 

 

Tools may only be used on devices, components or assemblies when it is certain that the devices are disconnected 
from the power supply and electrical charges stored in the components inside the device have been discharged. 

 

Live cables or wires to which the device or an assembly is connected, must always be tested for insulation faults or 
breaks. 

 

If an error is detected in the supply line, the device must be immediately taken out of operation until the faulty cable 
has been replaced. 

 

When using components or modules it is absolutely necessary to comply with the requirements set out in the 
accompanying description specifications for electrical quantities. 

 

If the available description is not clear to the non-commercial end-user what the applicable electrical characteristics for 
a part or assembly are, how to connect an external circuit, which external components or additional devices can be 
connected or which values these external components may have, a qualified electrician must be consulted. 

 

It must be examined generally before the commissioning of a device, whether this device or module is basically 
suitable for the application in which it is to be used. 

 

In case of doubt, consultation with experts or the manufacturer of the components used is absolutely necessary. 

 

For operational and connection errors outside of our control, we assume no liability of any kind for any resulting 
damage. 

 

Kits should be returned without their housing when not functional with an exact error description and the 
accompanying instructions. Without an error description it is not possible to repair. For time-consuming assembly or 
disassembly of cases charges will be invoiced. 

 

During installation and handling of components which later have mains potential on their parts, the relevant VDE 
regulations must be observed. 

 

Devices that are to be operated at a voltage greater than 35 VDC / 12mA, may only be connected by a qualified 
electrician and put into operation. 

 

Commissioning may only be realized if the circuit is built into a contact proof housing. 

 

If measurements with an open housing are unavoidable, for safety reasons an isolating transformer must be installed 
upstream or a suitable power supply can be used.  

 

After installing the required tests according to DGUV / regulation 3 (German statutory accident insurance, 

https://en.wikipedia.org/wiki/German_Statutory_Accident_Insurance

) must be carried out. 

 

18 

Warranty 

ESERA GmbH guarantees that the goods sold at the time of transfer of risk to be free from material and workmanship 
defects and have the contractually assured characteristics. The statutory warranty period of two years begins from date of 
invoice. The warranty does not extend to the normal operational wear and normal wear and tear. Customer claims for 
damages, for example, for non-performance, fault in contracting, breach of secondary contractual obligations, 
consequential damages, damages resulting from unauthorized usage and other legal grounds are excluded. Excepting to 
this, ESERA GmbH accepts liability for the absence of a guaranteed quality resulting from intent or gross negligence. 
Claims made under the Product Liability Act are not affected. 
If defects occur for which the ESERA GmbH is responsible, and in the case of replacement goods, the replacement is 
faulty, the buyer has the right to have the original purchase price refunded or a reduction of the purchase price.  
ESERA GmbH accepts liability neither for the constant and uninterrupted availability of the ESERA GmbH or for technical 
or electronic errors in the online offer. 
We develop our products further and we reserve the right to make changes and improvements to any of the products 
described in this documentation without prior notice. If you need documentation or information about older product 
versions, contact us by email a

[email protected]

 

 

 
 
 
 

Summary of Contents for 11134

Page 1: ...tion With the Multisensor a simple monitoring and recording of the indoor climate is possible For heating systems individual room control and ventilation systems it is an important sensor to achieve a good and stable control of temperature humidity The Multisensor is also optimal to warn of possible mould growth A calibration of the internal sensors is not necessary The unit can be put into operat...

Page 2: ... 90 non condensing Dimensions outside 71 x 71 x 32mm L x W x H 5 Conformity EN 50090 2 2 EN 61000 4 2 ESD EN 61000 4 3 HF EN 61000 4 4 Burst EN 61000 4 5 Surge EN 61000 6 1 Interference immunity EN 61000 6 3 Interference radiation RoHS 6 Software Control The living area sensor is read out via 1 Wire commands for DS18B20 and DS2438 devices and is supported by many systems such as ESERA 1 Wire Contr...

Page 3: ...ary Details can be found on the ESERA website at Kompatible Steuerungen Zentralen FHEM Integration https www esera de service support kompatible steuerungen zentralen fhem integration 11 Manual calculation of sensor values The following formula can be used to evaluate the humidity sensor VDD operating voltage 5V VAD humidity sensor analog value of DS2438 Xsense light sensor analog value of DS2438 ...

Page 4: ...ustrial environments This ensures a very good system stability of the entire system Another advantage of cabling with CAT cable is that a linear bus topology can be achieved despite star shaped cable routing in buildings This is only possible due to the 8 wire cable structure of the CAT cable When using CAT7 cable the maximum possible cable length of the entire 1 wire network is reduced due to the...

Page 5: ...y necessary For operational and connection errors outside of our control we assume no liability of any kind for any resulting damage Kits should be returned without their housing when not functional with an exact error description and the accompanying instructions Without an error description it is not possible to repair For time consuming assembly or disassembly of cases charges will be invoiced ...

Page 6: ...ed designations of their respective owners and are hereby expressly recognized as such by us The mention of these designations logos names and trademarks is made for identification purposes only and does not represent a claim of any kind on the part of ESERA GmbH on these designations logos names and trademarks Moreover from their appearance on ESERA GmbH webpages it cannot be concluded that desig...

Reviews: