esera automation 1-Wire Gateway 11 Modbus TCP User Manual Download Page 2

All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of 
ESERA GmbH. Errors and technical modification subject to change. 



ESERA GmbH, ESERA-Automation 2020 

www.esera.de 

11336 V2.0 R1.0  Manual 

Page 2 of 9

 

 
 

 
 
The Auto-E-Connect functionality will be available from mid-2020 via 1-Wire Controllers, 1-Wire Gateways and  
1-Wire ECO from ESERA available. 
Further information on ESERA Auto-E-Connect can be found on the ESERA website, ESERA Config-Tool 3, or in 
the download area for this article in the ESERA Webshop. 
 

Product features 

Standalone controller 

The 1-Wire Gateway 11 Modbus is designed to control 1-Wire Networks. You no longer have to worry about 
1-Wire commands or algorithms to analyze sensor data. 1-Wire Gateway 11 Modbus scans 1-Wire Networks 
by itself in order to identify new sensors or actuator devices. All data found were automatically provided in a 
ready to use Modbus protocol format. 
 

Formatted Data Output 

1-Wire Gateway 11 Modbus provides plausibility checked sensor and actuator data in a ready to use format. E.g. 
temperature sensor provides values in Celsius degrees with 2 decimal places. You only need to divide this 
number by 100. Within the 1-Wire Gateway a product specific transformation table is available for most of our 
selling 1-Wire sensor and actuator products. 
 

Designed for all 1-Wire Networks 

The 1-Wire interface of the 1-Wire Gateway 11 Modbus is specially designed to securely support all sizes of 
1-Wire networks. 1-Wire sensor devices can be operated in parasitic or normal mode at the same time.  
The latest available most powerful 1-Wire interface for a maximum level of data security has been used. This 
includes complex network structures as well. 
 

1-Wire Gateway 11 Modbus configuration

 

Free configuration software (Config-Tool 3) is provided. When using Config-Tool 3, the latest documentation 
is available at any time hence it automatically updates via internet. This software is available for 

download

 on 

our webpage. Communication to Modbus TCP is parallel with no switching. 

 
System time / real time clock 

No real time clock available in your system? No problem at all. 1-Wire Gateway 11 Modbus is providing time and 
date as real time clock including an integrated backup battery. Data plausibility check is possible at any time. 

 
Power supply 

Input voltage for 1-Wire Gateway 11 Modbus is 9 

– 30 VDC. Therefore it can be used for 12 V as well as 24 

VDC (industrial applications). Appropriate hat-rail mounted power supplies or power plugs can be found in 
our webshop. 
 

Operation 

“How-To”-Videos for setup and operation can be found on our website 

www.esera.de

 (Service and Support 

– 

How to 

– Support videos). 

 
Basics and tips for 1-Wire network systems can be found in our webshop (

https://www.esera.de/1-wire-

grundlagen/

) or in our e-book which is also available in our webshop (

https://www.esera.de/service-

support/dokumentation/352/grundlagen-1-wire-bus-ebook?number=11901

).  

 

Technical data 

Data Interface: 

Modbus TCP and ESERA ASCII text protocol 

Ethernet Interface:  

TCP/IP or UDP     

  

 

- 10/100 MBit Ethernet Interface (RJ45)  

 

- Auto Negotiation (Full-duplex and Half-duplex)  

 

- Auto MDI/MDIX     

 

- Support for DHCP and fix IP-address  

Firmware Update:  

via ESERA Config-Tool 3  

Power supply:   

– 30 VDC  

Power consumption:  

maximum 500 mA   

1-Wire interface:  

1-Wire bus (5 V, GND and data)  

Protective circuits:  

ESD protection and polarity protection  

Connection:   

Screw terminals (up to 2,5 qmm wire cross section)  

Output voltage:  

5 V (+/- 10 %), maximum 200 mA, overload-proof and short-circuit-proof 

 

Isolation:   

Galvanic separation among data and 1-Wire interface  

Summary of Contents for 1-Wire Gateway 11 Modbus TCP

Page 1: ...tion please read this assembly and operating instruction carefully to the end especially the section referring to the safety notes We recommend to use Config Tool 3 for all kind of setup and configuration tasks Please find the latest release on our website at www esera de Please also refer to the Help Support section to find the user guide for Config Tool 3 2 Product description Standard Modbus TC...

Page 2: ... has been used This includes complex network structures as well 1 Wire Gateway 11 Modbus configuration Free configuration software Config Tool 3 is provided When using Config Tool 3 the latest documentation is available at any time hence it automatically updates via internet This software is available for download on our webpage Communication to Modbus TCP is parallel with no switching System time...

Page 3: ...7 Conformity EN 50090 2 2 EN 61000 4 2 ESD EN 61000 4 3 HF EN 61000 4 4 Burst EN 61000 4 5 Surge EN 61000 6 1 Fault free operation EN 61000 6 3 Stray radiation RoHS 8 LED indicators The module status will be displayed by various LEDs Please refer to the following table for their functions LED status Description Function LED Green PWR power indicator LED Green DATA LED flashes 3 times after power o...

Page 4: ...rors and technical modification subject to change ESERA GmbH ESERA Automation 2020 www esera de 11336 V2 0 R1 0 Manual Page 4 of 9 9 Wiring diagramm Module topside 1 Wire Bus 7 Ground 1 Wire 8 1 Wire Data 9 5 V Output Module bottom side supply voltage 9 30 VDC 1 Negative supply voltage 2 Positive supply voltage 10 Connection Example with multisensory ...

Page 5: ...n of this user guide complete or in part requires the written consent of ESERA GmbH Errors and technical modification subject to change ESERA GmbH ESERA Automation 2020 www esera de 11336 V2 0 R1 0 Manual Page 5 of 9 11 Connection Example with 1 Wire Hub III sensors and actuators ...

Page 6: ...ailable for download in our webshop 13 Firmware update A firmware update can be performed with the Config Tool 3 software under the DEBUG DATA tab The button DOWNLOAD FIRMWARE opens a window to download new software firmware for the 1 Wire Controller 1 Wire Gateway The firmware can be used for all device versions of the 1 Wire Controller and 1 Wire Gateway The corresponding functionality is releas...

Page 7: ...to port 5000 and CHCP mode The Modbus protocol is standardized configured Please refer to the following table for a partial address overview A complete address overview is available for download at the Programming Manual at the download area of the 1 Wire Gateway 11 Modbus Partial Modbus address specification Specification reading address number of words type of data Gateway No 60000 1 Word Articl...

Page 8: ... If the available description is not clear to the non commercial end user what the applicable electrical characteristics for a part or assembly are how to connect an external circuit which external components or additional devices can be connected or which values these external components may have a qualified electrician must be consulted It must be examined generally before the commissioning of a...

Page 9: ... prior notice If you need documentation or information about older product versions contact us by email at info esera de 20 Trademarks All mentioned designations logos names and trademarks including those which are not explicitly marked are trademarks registered trademarks or other copyright or trademarks or titles or legally protected designations of their respective owners and are hereby express...